B15AE34
Accelerator pedal sensor 1 signal is below operational range (Low fault range defined by parameter P1GF5).
Signal High Time Less Than Minimum
Accelerator Pedal Sensor #2 is used to calculate the accelerator pedal position.
1. Connector or wiring harness faulty
2. Accelerator pedal sensor 1 faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check accelerator pedal
3. Check VMCU
Accelerator Pedal Sensor Measuring Circuit 1
————————————————————————————————————————————————————————————
B15AE35
Accelerator pedal sensor 1 signal is above operational range (High fault range defined by parameter P1GF6).
Signal High Time Greater Than Maximum
Accelerator Pedal Sensor #2 is used to calculate the accelerator pedal position.
1. Connector or wiring harness faulty
2. Accelerator pedal sensor 1 faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check accelerator pedal
3. Check VMCU
Accelerator Pedal Sensor Measuring Circuit 1
————————————————————————————————————————————————————————————
B15AF34
Accelerator pedal sensor 2 signal is below operational range (Low fault range defined by parameter P1GF7).
Signal High Time Less Than Minimum
Accelerator Pedal Sensor #1 is used to calculate the accelerator pedal position.
1. Connector or wiring harness faulty
2. Accelerator pedal sensor 2 faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check accelerator pedal
3. Check VMCU
Accelerator Pedal Sensor Measuring Circuit 2
————————————————————————————————————————————————————————————
B15AF35
Accelerator pedal sensor 2 signal is above operational range (High fault range defined by parameter P1GF8).
Signal High Time Greater Than Maximum
Accelerator Pedal Sensor #1 is used to calculate the accelerator pedal position.
1. Connector or wiring harness faulty
2. Accelerator pedal sensor 2 faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check accelerator pedal
3. Check VMCU
Accelerator Pedal Sensor Measuring Circuit 2
————————————————————————————————————————————————————————————
B100111
Accelerator pedal power supply 1 has been shorted to
ground.
Circuit Short To Ground
Accelerator Pedal Sensor #2 is used to calculate the accelerator pedal position.
1. Wiring harness faulty 2. Actuator faulty 3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check accelerator pedal
3. Check VMCU
Accelerator Pedal Power Supply 1 Circuit
————————————————————————————————————————————————————————————
B100115
Accelerator pedal power supply 1 has been shorted to battery or open circuit.
Circuit Short To Battery or Open
Accelerator Pedal Sensor #2 is used to calculate the accelerator pedal position.
1. Wiring harness faulty 2. Actuator faulty 3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check accelerator pedal
3. Check VMCU
Accelerator Pedal Power Supply 1 Circuit
————————————————————————————————————————————————————————————
B100211
Accelerator pedal power supply 2 has been shorted to
ground.
Circuit Short To Ground
Accelerator Pedal Sensor #1 is used to calculate the accelerator pedal position.
1. Wiring harness faulty 2. Actuator faulty 3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check accelerator pedal
3. Check VMCU
Accelerator Pedal Power Supply 2 Circuit
————————————————————————————————————————————————————————————
B100215
Accelerator pedal power supply 2 has been shorted to battery or open
circuit.
Circuit Short To Battery or Open
Accelerator Pedal Sensor #1 is used to calculate the accelerator pedal position.
1. Wiring harness faulty 2. Actuator faulty 3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check accelerator pedal
3. Check VMCU
Accelerator Pedal Power Supply 2 Circuit
————————————————————————————————————————————————————————————
B150C62
Deviation in accelerator pedal sensor values.
Signal Compare Failure
Accelerator Pedal Sensor (#1 or #2) with the lowest value is used to calculate the accelerator pedal position.
“1. Wiring harness from accelerator pedal sensor faulty
2. Accelerator pedal sensor faulty
3. VMCU faulty”
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check accelerator pedal
3. Check VMCU
Accelerator Pedal Sensor
————————————————————————————————————————————————————————————
B100411
Body builder flexible switch 1 power supply has been shorted to ground.
Circuit Short To Ground
No power is supplied to the device connected to the BBEC.
1. Wiring harness faulty
2. Actuator faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check actuator
3. Check VMCU
Body Builder Flexible Switch 1 Output
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
————————————————————————————————————————————————————————————
B100415
Body builder flexible switch 1 power supply has been shorted to battery or open circuit.
Circuit Short To Battery or Open
No power is supplied to the device connected to the BBEC.
1. Wiring harness faulty
2. Actuator faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check actuator
3. Check VMCU
Body Builder Flexible Switch 1 Output
————————————————————————————————————————————————————————————
B100511
Body builder flexible switch 2 power supply has been shorted to ground.
Circuit Short To Ground
No power is supplied to the device connected to the BBEC.
1. Wiring harness faulty
2. Actuator faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check actuator
3. Check VMCU
Body Builder Flexible Switch 2 Output Circuit
————————————————————————————————————————————————————————————
B100515
Body builder flexible switch 2 power supply has been shorted to battery or open circuit.
Circuit Short To Battery or Open
No power is supplied to the device connected to the BBEC.
1. Wiring harness faulty
2. Actuator faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check actuator
3. Check VMCU
Body Builder Flexible Switch 2 Output Circuit
————————————————————————————————————————————————————————————
B151962
Vehicle deceleration to zero speed without brake switch indicating a pressed brake pedal.
Signal Compare Failure
No functional impact.
“1. Wiring harness from brake switch faulty
2. Brake switch faulty
3. Vehicle speed faulty (wiring harness / sensor)”
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check brake switch (B03)
3. Check vehicle speed sensor
Brake Pedal Switch
————————————————————————————————————————————————————————————
B100611
Power supply to the cab tilt motor pump has been shorted to ground.
Circuit Short To Ground
Not possible to operate the cab tilt.
1. Wiring harness faulty
2. Actuator faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check actuator
3. Check VMCU
Relay K28 Cab Tilt Motor Pump Control Circuit
————————————————————————————————————————————————————————————
B100615
Power supply to the cab tilt motor pump has been shorted to battery or open circuit.
Circuit Short To Battery or Open
Not possible to operate the cab tilt.
1. Wiring harness faulty
2. Actuator faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check actuator
3. Check VMCU
Relay K28 Cab Tilt Motor Pump Control Circuit
————————————————————————————————————————————————————————————
B15AD34
Clutch pedal sensor signal is below operational range defined by P1HIR.
Signal High Time Less Than Minimum
Not possible to determine the clutch pedal position.
1. Connector or wiring harness faulty
2. Clutch pedal sensor faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check clutch pedal
3. Check VMCU
Clutch Pedal Sensor Measuring Circuit
————————————————————————————————————————————————————————————
B15AD35
Clutch pedal sensor signal is above operational range defined by P1HIR.
Signal High Time Greater Than Maximum
Not possible to determine the clutch pedal position.
1. Connector or wiring harness faulty
2. Clutch pedal sensor faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check clutch pedal
3. Check VMCU
Clutch Pedal Sensor Measuring Circuit
————————————————————————————————————————————————————————————
B152A11
Clutch pedal switch/sensor power supply has been shorted to ground.
Circuit Short To Ground
Not possible to determine the clutch pedal position.
1. Wiring harness faulty
2. Actuator faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check actuator
3. Check VMCU
Clutch Pedal Linear Sensor/Switch Power Supply Circuit
————————————————————————————————————————————————————————————
B152A15
Clutch pedal switch/sensor power supply has been shorted to battery or open circuit.
Circuit Short To Battery or Open
Not possible to determine the clutch pedal position.
1. Wiring harness faulty
2. Actuator faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check actuator
3. Check VMCU
Clutch Pedal Linear Sensor/Switch Power Supply Circuit
————————————————————————————————————————————————————————————
B15BC54
Clutch Pedal Linear Sensor not
calibrated.
Missing Calibration
Not possible to determine the clutch pedal position.
Default values for pressed / released end positions.
Diagnostic Service 14. No additional action is needed.
Perform a calibration of the Clutch Pedal Linear Sensor using Routine Identifier R1AFT.
Clutch Pedal Linear Sensor
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
————————————————————————————————————————————————————————————
B15C082
1. Input signal status is NOT OK
2. Input signal is received
Alive / Sequence Counter Incorrect / Not Updated
The status signal sets to error
1. Until the input status is OK
2. Until the input signal is received with correct
expected signal value
1. Input signal status is NOT OK
2. Software error (signal publisher swc sends incorrect expected value)
Diagnostic Service 14. No additional action is needed.
Reprogram ECU
Collision Warning Emergency Braking System
————————————————————————————————————————————————————————————
U210164
Unexpected change in transmission ratio.
Signal Plausibility Failure
Cruise Control is exited if it is active when the failure occurrs.
“1. Wiring harness from clutch switch faulty
2. Clutch switch faulty
3. Wiring harness from neutral switch faulty
4. Neutral switch faulty
5. Vehicle speed faulty (wiring harness / sensor) or engine speed (EMS) faulty”
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check clutch switch
3. Check wires and connectors
4. Check neutral switch
5. Check vehicle speed sensor
Cruise control status
————————————————————————————————————————————————————————————
B151812
Mirror heating relay coil has been shorted to battery.
Circuit Short To Battery
Not possible to operate the mirror heater in the driver and passenger doors.
1. Mirror heating relay faulty
2. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check mirror heating relay (K21)
2. Check VMCU
Relay K21 Mirror Heating Circuit
————————————————————————————————————————————————————————————
B151814
Mirror heating relay coil has been shorted to ground or open circuit.
Circuit Short To Ground or Open
Not possible to operate the mirror heater in the driver and passenger doors.
1. Mirror heating relay faulty
2. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check mirror heating relay (K21)
2. Check VMCU
Relay K21 Mirror Heating Circuit
————————————————————————————————————————————————————————————
B150211
Body Builder Tail Lift/Crane power supply has been shorted to ground.
Circuit Short To Ground
Not possible to operate the Tail Lift or Crane.
1. Wiring harness faulty
2. Actuator faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check actuator
3. Check VMCU
Body Builder Tail Lift/Crane Enable Circuit
————————————————————————————————————————————————————————————
B150215
Body Builder Tail Lift/Crane power supply has been shorted to battery or
open circuit.
Circuit Short To Battery or Open
Not possible to operate the Tail Lift or Crane.
1. Wiring harness faulty
2. Actuator faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check actuator
3. Check VMCU
Body Builder Tail Lift/Crane Enable Circuit
————————————————————————————————————————————————————————————
B150511
Cab body working lamps has been shorted to ground.
Circuit Short To Ground
Not possible to use the Cab/Body Working Light.
1. Wiring harness faulty
2. Actuator faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check Actuator
3. Check VMCU
Cab Body Working Lamps Circuit
————————————————————————————————————————————————————————————
B150515
Cab body working lamps has been shorted to battery or
open circuit.
Circuit Short To Battery or Open
Not possible to use the Cab/Body Working Light.
1. Wiring harness faulty
2. Actuator faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check Actuator
3. Check VMCU
Cab Body Working Lamps Circuit
————————————————————————————————————————————————————————————
B150611
Side reverse working lights has been shorted to ground.
Circuit Short To Ground
Not possible to use the Side/Reverse Working Light.
1. Wiring harness faulty
2. Actuator faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check FSP
3. Check VMCU
Side Reverse Working Lights
————————————————————————————————————————————————————————————
B150615
Side reverse working lights has been shorted to battery or open circuit.
Circuit Short To Battery or Open
Not possible to use the Side/Reverse Working Light.
1. Wiring harness faulty
2. Actuator faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check FSP
3. Check VMCU
Side Reverse Working Lights
————————————————————————————————————————————————————————————
B150711
Front extra spot lamps have been shorted to ground.
Circuit Short To Ground
Not possible to use the Extra Spot Lamp Front.
1. Wiring harness faulty
2. Actuator faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check FSP
3. Check VMCU
Front Extra Spot Lamps Circuit
————————————————————————————————————————————————————————————
B150715
Front extra spot lamps have been shorted to battery or
open circuit.
Circuit Short To Battery or Open
Not possible to use the Extra Spot Lamp Front.
1. Wiring harness faulty
2. Actuator faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check FSP
3. Check VMCU
Front Extra Spot Lamps Circuit
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
————————————————————————————————————————————————————————————
B150811
Extra parking lights have been shorted to ground.
Circuit Short To Ground
Not possible to use the Extra Parking Lights.
1. Wiring harness faulty
2. Actuator faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check FSP
3. Check VMCU
Extra Parking Lights
————————————————————————————————————————————————————————————
B150815
Extra parking lights have been shorted to battery or open
circuit.
Circuit Short To Battery or Open
Not possible to use the Extra Parking Lights.
1. Wiring harness faulty
2. Actuator faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check FSP
3. Check VMCU
Extra Parking Lights
————————————————————————————————————————————————————————————
B152212
Roof light sign relay coil has been shorted to battery.
Circuit Short To Battery
Not possible to use the Roof Sign Light.
1. Roof light sign relay faulty
2. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check roof light sign relay (K12)
2. Check VMCU
Relay K12 Roof Light Sign
/ Roof Triangle Circuit
————————————————————————————————————————————————————————————
B152214
Roof light sign relay coil has been shorted to ground or open circuit.
Circuit Short To Ground or Open
Not possible to use the Roof Sign Light.
1. Roof light sign relay faulty
2. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check roof light sign relay (K12)
2. Check VMCU
Relay K12 Roof Light Sign
/ Roof Triangle Circuit
————————————————————————————————————————————————————————————
B152312
Extra spot lamps relay coil has been shorted to battery.
Circuit Short To Battery
Not possible to use the Extra Spot Lamps on Roof.
1. Extra spot lamps relay faulty
2. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check extra spot lamps relay (K10)
2. Check VMCU
Relay K10 Extra Spot Lamps Roof / Roof Triangle Power Circuit
————————————————————————————————————————————————————————————
B152314
Extra spot lamps relay coil has been shorted to ground or open circuit.
Circuit Short To Ground or Open
Not possible to use the Extra Spot Lamps on Roof.
1. Extra spot lamps relay faulty
2. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check extra spot lamps relay (K10)
2. Check VMCU
Relay K10 Extra Spot Lamps Roof / Roof Triangle Power Circuit
————————————————————————————————————————————————————————————
B151E12
Trailer body light relay coil has been shorted to battery.
Circuit Short To Battery
Not possible to use the Trailer Body Light.
1. Trailer body light relay faulty
2. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check trailer body light relay (K19)
2. Check VMCU
Relay K19 Trailer Body Lighting Circuit
————————————————————————————————————————————————————————————
B151E14
Trailer body light relay coil has been shorted to ground or open circuit.
Circuit Short To Ground or Open
Not possible to use the Trailer Body Light.
1. Trailer body light relay faulty
2. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check trailer body light relay (K19)
2. Check VMCU
Relay K19 Trailer Body Lighting Circuit
————————————————————————————————————————————————————————————
B151F12
Beacon warning lamps relay coil has been shorted to
battery.
Circuit Short To Battery
Not possible to use the Beacon Warning Lamps.
1. Beacon warning lamps relay faulty
2. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check beacon warning lamps relay (K13)
2. Check VMCU
Relay K13 Beacon Warning / Roof Spot Lamps Circuit
————————————————————————————————————————————————————————————
B151F14
Beacon warning lamps relay coil has been shorted to ground or open
circuit.
Circuit Short To Ground or Open
Not possible to use the Beacon Warning Lamps.
1. Beacon warning lamps relay faulty
2. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check beacon warning lamps relay (K13)
2. Check VMCU
Relay K13 Beacon Warning / Roof Spot Lamps Circuit
————————————————————————————————————————————————————————————
B15B868
Roller Bench Mode is enabled.
Event Information
Not possible to engage Front Wheel Drive.
Roller Bench Mode is enabled by parameter
P1KM2.
Diagnostic Service 14. No additional action is needed.
Disable Roller Bench Mode by parameter P1KM2.
Roller Bench Mode Active
————————————————————————————————————————————————————————————
U30004A
Incorrect data from FRC diagnostics.
Incorrect Component Installed
FRC diagnostics will be unavailable.
Wrong type of FRC mounted.
Diagnostic Service 14. No additional action is needed.
Replace FRC.
Electronic control unit
————————————————————————————————————————————————————————————
B153B13
Fuse blown
Circuit Open
Loss of SID power supply
Fuse F21 is blown
Diagnostic Service 14. No additional action is needed.
Replace fuse.
Fuse F21
————————————————————————————————————————————————————————————
B155F13
Fuse blown
Circuit Open
None
Fuse F82 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F82
————————————————————————————————————————————————————————————
B153C13
Fuse blown
Circuit Open
Loss of Trailer ABS/EBS
power supply
Fuse F46 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F46
————————————————————————————————————————————————————————————
B156013
Fuse blown
Circuit Open
None
Fuse F83 is blown
Diagnostic Service 14. No additional action is needed.
Replace fuse.
Fuse F83
————————————————————————————————————————————————————————————
B153D13
Fuse blown
Circuit Open
Loss of ABS/EBS power
supply
Fuse F37 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F37
————————————————————————————————————————————————————————————
B156113
Fuse blown
Circuit Open
None
Fuse F79 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F79
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
————————————————————————————————————————————————————————————
B153E13
Fuse blown
Circuit Open
Loss of DACU power supply
Fuse F31 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F31
————————————————————————————————————————————————————————————
B156213
Fuse blown
Circuit Open
Loss of FMS connector ignition supply
Fuse F85 is blown
Diagnostic Service 14. No additional action is needed.
Replace fuse.
Fuse F85
————————————————————————————————————————————————————————————
B153F13
Fuse blown
Circuit Open
Loss of Toll collect Battery
supply
Fuse F25 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F25
————————————————————————————————————————————————————————————
B156313
Fuse blown
Circuit Open
Loss of BB Electrical Centre
ignition supply 1
Fuse F73 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F73
————————————————————————————————————————————————————————————
B154013
Fuse blown
Circuit Open
Loss of OBDII diagnostic connector supply
Fuse F62 is blown
Diagnostic Service 14. No additional action is needed.
Replace fuse.
Fuse F62
————————————————————————————————————————————————————————————
B156413
Fuse blown
Circuit Open
Loss of BB Electrical Centre
ignition supply 2
Fuse F74 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F74
————————————————————————————————————————————————————————————
B154113
Fuse blown
Circuit Open
Loss of FMS connector
power supply
Fuse F91 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F91
————————————————————————————————————————————————————————————
B156513
Fuse blown
Circuit Open
Loss of EMS ECU power
supply
Fuse F41 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F41
————————————————————————————————————————————————————————————
B154213
Fuse blown
Circuit Open
None
Fuse F35 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F35
————————————————————————————————————————————————————————————
B156613
Fuse blown
Circuit Open
Loss of EMS controlled loads 1
Fuse F42 is blown
Diagnostic Service 14. No additional action is needed.
Replace fuse.
Fuse F42
————————————————————————————————————————————————————————————
B154313
Fuse blown
Circuit Open
None
Fuse F47 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F47
————————————————————————————————————————————————————————————
B156713
Fuse blown
Circuit Open
Loss of Fuel filter heater
Fuse F43 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F43
————————————————————————————————————————————————————————————
B154413
Fuse blown
Circuit Open
Loss of Electrical front lid lock supply
Fuse F34 is blown
Diagnostic Service 14. No additional action is needed.
Replace fuse.
Fuse F34
————————————————————————————————————————————————————————————
B156813
Fuse blown
Circuit Open
Loss of EMS controlled
loads 2
Fuse F44 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F44
————————————————————————————————————————————————————————————
B154513
Fuse blown
Circuit Open
None
Fuse F89 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F89
————————————————————————————————————————————————————————————
B154613
Fuse blown
Circuit Open
None
Fuse F09 is blown
Diagnostic Service 14. No additional action is needed.
Replace fuse.
Fuse F09
————————————————————————————————————————————————————————————
B154713
Fuse blown
Circuit Open
None
Fuse F72 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F72
————————————————————————————————————————————————————————————
B154813
Fuse blown
Circuit Open
Loss of Sun visor supply
Fuse F22 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F22
————————————————————————————————————————————————————————————
B154913
Fuse blown
Circuit Open
Loss of TIS&Telematics System (old TGW) power supply
Fuse F66 is blown
Diagnostic Service 14. No additional action is needed.
Replace fuse.
Fuse F66
————————————————————————————————————————————————————————————
B154A13
Fuse blown
Circuit Open
Loss of VS (Video Switch)
power supply
Fuse F53 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F53
————————————————————————————————————————————————————————————
B159D16
No power detected
Circuit Voltage Below Threshold
Voltage drop on 20A headersherlf DC/DC convertor outputs (12V Power Supply for Wired phone, Mobile phone, TV- DVD, CB Pwr)
1. Header shelf DC/DC converter is damaged.
2. 24 V power supply connection problem
3. 12 V output power supply connection problem
Diagnostic Service 14. No additional action is needed.
Check DC/DC converter.
Front Shelf 24V/12V Converter
————————————————————————————————————————————————————————————
B154B13
Fuse blown
Circuit Open
Loss of power on
Dashboard 12V-Socket
Fuse F01 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F01
————————————————————————————————————————————————————————————
B159E16
No power detected
Circuit Voltage Below Threshold
Voltage drop on 12V power supply for Dashboard 12V- Socket, Sleeper 12V-Socket, Audio Control unit 12V- power supply, Audio Control unit 12V- Accessories
1. Dashboard DC/DC converter is damaged.
2. 24 V power supply connection problem
3. 12 V output power supply connection problem
Diagnostic Service 14. No additional action is needed.
Check DC/DC converter.
Dashboard 24V/12V Converter
————————————————————————————————————————————————————————————
B154C13
Fuse blown
Circuit Open
Loss of power supply on TV-
DVD, Wired phone, Mobile phone
Fuse F03 is blown
Diagnostic Service 14. No additional action is needed.
Replace fuse.
Fuse F03
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
————————————————————————————————————————————————————————————
B154D13
No power detected
Circuit Open
Loss of Power supply for
Coffee maker
1. Fuse F50 is blown
2. Relay K08 is damaged.
Diagnostic Service 14. No additional
action is needed.
Replace fuse or relay
Fuse F50/Relay K08
————————————————————————————————————————————————————————————
B154E13
Fuse blown
Circuit Open
None
1. Fuse F54 is blown
2. Relay K08 is damaged.
Diagnostic Service 14. No additional action is needed.
Replace fuse.
Fuse F54
————————————————————————————————————————————————————————————
B152B13
Fuse blown
Circuit Open
Loss of TACHO Power
supply
Fuse F23 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F23
————————————————————————————————————————————————————————————
B154F13
Fuse blown
Circuit Open
Loss of BB Electrical Centre
main supply 1
Fuse F07 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F07
————————————————————————————————————————————————————————————
B152C13
Fuse blown
Circuit Open
Loss of CIOM Power supply
Fuse F63 is blown
Diagnostic Service 14. No additional action is needed.
Replace fuse.
Fuse F63
————————————————————————————————————————————————————————————
B155013
Fuse blown
Circuit Open
Loss of BB Electrical Centre
main supply 2
Fuse F08 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F08
————————————————————————————————————————————————————————————
B152D13
Fuse blown
Circuit Open
Loss of ALARM Power
supply
Fuse F55 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F55
————————————————————————————————————————————————————————————
B155113
Fuse blown
Circuit Open
Loss of BB Electrical centre switches power supply
Fuse F06 is blown
Diagnostic Service 14. No additional action is needed.
Replace fuse.
Fuse F06
————————————————————————————————————————————————————————————
B152E13
Fuse blown
Circuit Open
Loss of HMIIOM Power
supply
Fuse F18 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse
Fuse F18
————————————————————————————————————————————————————————————
B155213
Fuse blown
Circuit Open
Loss of Trailer plug power
supply
Fuse F04 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F04
————————————————————————————————————————————————————————————
B152F13
Fuse blown
Circuit Open
Loss of DDM power supply
Fuse F61 is blown
Diagnostic Service 14. No additional action is needed.
Replace fuse.
Fuse F61
————————————————————————————————————————————————————————————
B155313
Fuse blown
Circuit Open
Loss of BB Chassis power
supply
Fuse F05 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F05
————————————————————————————————————————————————————————————
B153013
Fuse blown
Circuit Open
Loss of PDM power supply
Fuse F20 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F20
————————————————————————————————————————————————————————————
B155413
Fuse blown
Circuit Open
Loss of 24V power outlet supply 1
Fuse F64 is blown
Diagnostic Service 14. No additional action is needed.
Replace fuse.
Fuse F64
————————————————————————————————————————————————————————————
B153113
Fuse blown
Circuit Open
Loss of Wireless remote
control charger supply
Fuse F33 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F33
————————————————————————————————————————————————————————————
B155513
Fuse blown
Circuit Open
Loss of 24V power outlet
supply 2
Fuse F65 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F65
————————————————————————————————————————————————————————————
B153213
Fuse blown
Circuit Open
None
Fuse F84 is blown
Diagnostic Service 14. No additional action is needed.
Replace fuse.
Fuse F84
————————————————————————————————————————————————————————————
B155613
Fuse blown
Circuit Open
Loss of 24V power outlet
supply 3
Fuse F10 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F10
————————————————————————————————————————————————————————————
B153313
Fuse blown
Circuit Open
Loss of Fuel line heater
power supply
Fuse F39 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F39
————————————————————————————————————————————————————————————
B155713
Fuse blown
Circuit Open
Loss of Cigarette lighter
power supply
Fuse F67 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F67
————————————————————————————————————————————————————————————
B153413
Fuse blown
Circuit Open
Loss of Cab parking heater
power supply
Fuse F69 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F69
————————————————————————————————————————————————————————————
B155813
Fuse blown
Circuit Open
Loss of AlcoLock power supply
Fuse F88 is blown
Diagnostic Service 14. No additional action is needed.
Replace fuse.
Fuse F88
————————————————————————————————————————————————————————————
B153513
Fuse blown
Circuit Open
Loss of APM power supply 1
Fuse F32 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F32
————————————————————————————————————————————————————————————
B155913
Fuse blown
Circuit Open
Loss of BB Prep kit power
supply
Fuse F56 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F56
————————————————————————————————————————————————————————————
B153613
Fuse blown
Circuit Open
None
Fuse F48 is blown
Diagnostic Service 14. No additional action is needed.
Replace fuse.
Fuse F48
————————————————————————————————————————————————————————————
B153713
Fuse blown
Circuit Open
Loss of IC power supply
Fuse F24 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F24
————————————————————————————————————————————————————————————
B155A13
Fuse blown
Circuit Open
Loss of Amplifier power
supply
Fuse F58 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F58
————————————————————————————————————————————————————————————
B155B13
Fuse blown
Circuit Open
Loss of Headershelf DC/DC Converter power supply
Fuse F59 is blown
Diagnostic Service 14. No additional action is needed.
Replace fuse.
Fuse F59
————————————————————————————————————————————————————————————
B153813
Fuse blown
Circuit Open
Loss of BBM power supply
Fuse F19 is blown
Diagnostic Service 14. No additional action is needed.
Replace fuse.
Fuse F19
————————————————————————————————————————————————————————————
B155C13
Fuse blown
Circuit Open
Loss of Dashboard DC/DC
Converter power supply
Fuse F60 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F60
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
————————————————————————————————————————————————————————————
B153913
Fuse blown
Circuit Open
Loss of LECM power supply
Fuse F80 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F80
————————————————————————————————————————————————————————————
B155D13
Fuse blown
Circuit Open
Loss of Task lights power supply
Fuse F57 is blown
Diagnostic Service 14. No additional action is needed.
Replace fuse.
Fuse F57
————————————————————————————————————————————————————————————
B153A13
Fuse blown
Circuit Open
Loss of CCM power supply
Fuse F38 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F38
————————————————————————————————————————————————————————————
B155E13
Fuse blown
Circuit Open
Loss of SRS power supply
Fuse F81 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F81
————————————————————————————————————————————————————————————
B157772
Relay stuck in opened
Actuator Stuck Open
Loss of BB main power supply (Power Supply Relay 2)
Relay K07 is damaged
Diagnostic Service 14. No additional action is needed.
Replace relay.
Relay K07
————————————————————————————————————————————————————————————
B157773
Relay stuck in closed
Actuator Stuck Closed
BB main power supply always ON
Relay K07 is damaged
Diagnostic Service 14. No additional action is needed.
Replace relay.
Relay K07
————————————————————————————————————————————————————————————
B157872
Relay stuck in
opened
Actuator Stuck Open
Loss of Power suppy 3
Relay K14 is damaged
Diagnostic Service 14. No additional
action is needed.
Replace relay.
Relay K14
————————————————————————————————————————————————————————————
B157873
Relay stuck in closed
Actuator Stuck Closed
Power supply 3 always ON
Relay K14 is damaged
Diagnostic Service 14. No additional action is needed.
Replace relay.
Relay K14
————————————————————————————————————————————————————————————
B157972
Relay stuck in
opened
Actuator Stuck Open
Loss of Power supply 4
Relay K11 is damaged
Diagnostic Service 14. No additional
action is needed.
Replace relay.
Relay K11
————————————————————————————————————————————————————————————
B157973
Relay stuck in closed
Actuator Stuck Closed
Power supply 4 always ON
Relay K11 is damaged
Diagnostic Service 14. No additional
action is needed.
Replace relay.
Relay K11
————————————————————————————————————————————————————————————
B157A72
Relay stuck in opened
Actuator Stuck Open
Loss of Ignition power supply
Relay K22 is damaged
Diagnostic Service 14. No additional action is needed.
Replace relay.
Relay K22
————————————————————————————————————————————————————————————
B157A73
Relay stuck in closed
Actuator Stuck Closed
Ignition power supply
always ON
Relay K22 is damaged
Diagnostic Service 14. No additional
action is needed.
Replace relay.
Relay K22
————————————————————————————————————————————————————————————
B157B72
Relay stuck in
opened
Actuator Stuck Open
Loss of BB Ignition power
supply
Relay K20 is damaged
Diagnostic Service 14. No additional
action is needed.
Replace relay.
Relay K20
————————————————————————————————————————————————————————————
B157B73
Relay stuck in closed
Actuator Stuck Closed
BB Ignition power supply always ON
Relay K20 is damaged
Diagnostic Service 14. No additional action is needed.
Replace relay.
Relay K20
————————————————————————————————————————————————————————————
B157C73
Relay stuck in closed
Actuator Stuck Closed
Cab tilt pump power supply
always ON
Relay K28 is damaged
Diagnostic Service 14. No additional
action is needed.
Replace relay.
Relay K28
————————————————————————————————————————————————————————————
B157D72
Relay stuck in
opened
Actuator Stuck Open
Loss of EMS power supply
Relay K27 is damaged
Diagnostic Service 14. No additional
action is needed.
Replace relay.
Relay K27
————————————————————————————————————————————————————————————
B157D73
Relay stuck in closed
Actuator Stuck Closed
EMS power supply always ON
Relay K27 is damaged
Diagnostic Service 14. No additional action is needed.
Replace relay.
Relay K27
————————————————————————————————————————————————————————————
B157E72
Relay stuck in
opened
Actuator Stuck Open
Loss of Mirror Heating
power supply
Relay K21 is damaged
Diagnostic Service 14. No additional
action is needed.
Replace relay.
Relay K21
————————————————————————————————————————————————————————————
B157E73
Relay stuck in closed
Actuator Stuck Closed
Mirror Heating power
supply always ON
Relay K21 is damaged
Diagnostic Service 14. No additional
action is needed.
Replace relay.
Relay K21
————————————————————————————————————————————————————————————
B157F73
Relay stuck in closed
Actuator Stuck Closed
Seat movement power
supply always ON
Relay K24 is damaged
Diagnostic Service 14. No additional
action is needed.
Replace relay.
Relay K24
————————————————————————————————————————————————————————————
B158073
Relay stuck in closed
Actuator Stuck Closed
Engine Running power
supply always ON
Relay K09 is damaged
Diagnostic Service 14. No additional
action is needed.
Replace relay.
Relay K09
————————————————————————————————————————————————————————————
B156913
Fuse blown
Circuit Open
Loss of Tacho Ignition supply
Fuse F40 is blown
Diagnostic Service 14. No additional action is needed.
Replace fuse.
Fuse F40
————————————————————————————————————————————————————————————
B156A13
Fuse blown
Circuit Open
Loss of Mirror heating 1
power supply (Heater, rear- view mirror, right)
Fuse F29 is blown
Diagnostic Service 14. No additional action is needed.
Replace fuse.
Fuse F29
————————————————————————————————————————————————————————————
B156B13
Fuse blown
Circuit Open
Loss of Mirror heating 2
power supply (Heater, rear- view mirror, left)
Fuse F30 is blown
Diagnostic Service 14. No additional action is needed.
Replace fuse.
Fuse F30
————————————————————————————————————————————————————————————
B156C13
No power detected.
Circuit Open
Loss of power for El. adjustable seat, Hourmeter and Alcolock engine running
signal
1. Fuse F13 is blown
2. Relay K09 is damaged.
Diagnostic Service 14. No additional action is needed.
Replace fuse or relay.
Fuse F13/Relay K09
————————————————————————————————————————————————————————————
B156D13
Fuse blown
Circuit Open
None
Fuse F14 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F14
————————————————————————————————————————————————————————————
B156E13
Fuse blown
Circuit Open
Lolss of power supply for
Sun Roof motor
Fuse F52 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F52
————————————————————————————————————————————————————————————
B156F13
Fuse blown
Circuit Open
Loss of power supply for Windscreen Wiper motor
Fuse F51 is blown
Diagnostic Service 14. No additional action is needed.
Replace fuse.
Fuse F51
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
————————————————————————————————————————————————————————————
B157013
Fuse blown
Circuit Open
None
Fuse F77 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F77
————————————————————————————————————————————————————————————
B157113
Fuse blown
Circuit Open
None
Fuse F86 is blown
Diagnostic Service 14. No additional action is needed.
Replace fuse.
Fuse F86
————————————————————————————————————————————————————————————
B157213
Fuse blown
Circuit Open
None
Fuse F78 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F78
————————————————————————————————————————————————————————————
B157313
Fuse blown
Circuit Open
Loss of power supply for Refrigerator and Electrical
handle
Fuse F75 is blown
Diagnostic Service 14. No additional action is needed.
Replace fuse.
Fuse F75
————————————————————————————————————————————————————————————
B157413
Fuse blown
Circuit Open
None
Fuse F02 is blown
Diagnostic Service 14. No additional
action is needed.
Replace fuse.
Fuse F02
————————————————————————————————————————————————————————————
B159113
No power detected
Circuit Open
None
1. Fuse F87 is blown
2. Relay K25 is damaged
Diagnostic Service 14. No additional action is needed.
Replace fuse or relay.
Fuse F87/Relay K25
————————————————————————————————————————————————————————————
B159213
No power detected
Circuit Open
Loss of Cab tilt pump motor
power supply
1. Fuse F45 is blown
2. Relay K28 is damaged
Diagnostic Service 14. No additional
action is needed.
Replace fuse or relay.
Fuse F45/Relay K28
————————————————————————————————————————————————————————————
B159313
No power detected
Circuit Open
Loss of power supply for Seat motor
1. Fuse F90 is blown
2. Relay K24 is damaged
Diagnostic Service 14. No additional action is needed.
Replace fuse or relay.
Fuse F90/Relay K24
————————————————————————————————————————————————————————————
B159413
No power detected
Circuit Open
Loss of power supply for
Headlight washer
1. Fuse F71 is blown
2. Relay K16 is damaged
Diagnostic Service 14. No additional
action is needed.
Replace fuse or relay.
Fuse F71/Relay K16
————————————————————————————————————————————————————————————
B159513
No power detected
Circuit Open
Loss of power supply for
Trailer Body Light EL8
1. Fuse F76 is blown
2. Relay K19 is damaged
Diagnostic Service 14. No additional
action is needed.
Replace fuse or relay.
Fuse F76/Relay K19
————————————————————————————————————————————————————————————
B159613
No power detected
Circuit Open
Loss of power supply for Extra spot lamps roof/front
1. Fuse F11 is blown
2. Relay K10 is damaged
Diagnostic Service 14. No additional action is needed.
Replace fuse or relay.
Fuse F11/Relay K10
————————————————————————————————————————————————————————————
B159713
No power detected
Circuit Open
Loss of power supply for Beacon warning lamps
1. Fuse F12 is blown
2. Relay K13 is damaged
Diagnostic Service 14. No additional action is needed.
Replace fuse or relay.
Fuse F12/Relay K13
————————————————————————————————————————————————————————————
B159813
No power detected
Circuit Open
Loss of power supply for
Roof light sign lamps
1. Fuse F15 is blown
2. Relay K12 is damaged
Diagnostic Service 14. No additional
action is needed.
Replace fuse or relay.
Fuse F15/Relay K12
————————————————————————————————————————————————————————————
B159913
No power detected
Circuit Open
Loss of power supply for Full beam inside sign area
lamps
1. Fuse F16 is blown
2. Relay K15 is damaged
Diagnostic Service 14. No additional action is needed.
Replace fuse or relay.
Fuse F16/Relay K15
————————————————————————————————————————————————————————————
B159A13
No power detected
Circuit Open
Loss of TECU power supply
1. Fuse F70 is blown
2. Relay K17 is damaged
Diagnostic Service 14. No additional
action is needed.
Replace fuse or relay.
Fuse F70/Relay K17
————————————————————————————————————————————————————————————
B159B13
No power detected
Circuit Open
None
1. Fuse F36 is blown
2. Relay K26 is damaged
Diagnostic Service 14. No additional action is needed.
Replace fuse or relay.
Fuse F36/Relay K26
————————————————————————————————————————————————————————————
B159C13
No power detected
Circuit Open
None
1. Fuse F17 is blown
2. Relay K18 is damaged
Diagnostic Service 14. No additional
action is needed.
Replace fuse or relay.
Fuse F17/Relay K18
————————————————————————————————————————————————————————————
B157573
Relay stuck in closed
Actuator Stuck Closed
Coffee maker power supply
always ON
Relay K08 is damaged
Diagnostic Service 14. No additional
action is needed.
Replace relay.
Relay K08
————————————————————————————————————————————————————————————
B157673
Relay stuck in closed
Actuator Stuck Closed
None
Relay K25 is damaged
Diagnostic Service 14. No additional
action is needed.
Replace relay.
Relay K25
————————————————————————————————————————————————————————————
B158172
Relay stuck in
opened
Actuator Stuck Open
Loss of power supply for
Sunroof motor1
Relay K04 is damaged
Diagnostic Service 14. No additional
action is needed.
Replace relay.
Relay K04
————————————————————————————————————————————————————————————
B158173
Relay stuck in closed
Actuator Stuck Closed
Sunroof motor1 power supply always ON
Relay K04 is damaged
Diagnostic Service 14. No additional action is needed.
Replace relay.
Relay K04
————————————————————————————————————————————————————————————
B158272
Relay stuck in
opened
Actuator Stuck Open
Loss of power supply for
Sunroof motor2
Relay K03 is damaged
Diagnostic Service 14. No additional
action is needed.
Replace relay.
Relay K03
————————————————————————————————————————————————————————————
B158273
Relay stuck in closed
Actuator Stuck Closed
Sunroof motor2 power
supply always ON
Relay K03 is damaged
Diagnostic Service 14. No additional
action is needed.
Replace relay.
Relay K03
————————————————————————————————————————————————————————————
B158373
Relay stuck in closed
Actuator Stuck Closed
Head Light Washer Pump power supply always ON
Relay K16 is damaged
Diagnostic Service 14. No additional action is needed.
Replace relay.
Relay K16
————————————————————————————————————————————————————————————
B158472
Relay stuck in opened
Actuator Stuck Open
Intermittent mode of Windscreen wiper not
available
Relay K05 is damaged
Diagnostic Service 14. No additional action is needed.
Replace relay.
Relay K05
————————————————————————————————————————————————————————————
B158473
Relay stuck in closed
Actuator Stuck Closed
Intermittent mode of
Windscreen wiper not available
Relay K05 is damaged
Diagnostic Service 14. No additional action is needed.
Replace relay.
Relay K05
————————————————————————————————————————————————————————————
B158572
Relay stuck in opened (motor low speed position)
Actuator Stuck Open
High speed mode of Windscreen wiper not available
Relay K06 is damaged
Diagnostic Service 14. No additional action is needed.
Replace relay.
Relay K06
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
————————————————————————————————————————————————————————————
B158573
Relay stuck in closed (motor high speed position)
Actuator Stuck Closed
Low speed mode of Windscreen wiper not available
Relay K06 is damaged
Diagnostic Service 14. No additional action is needed.
Replace relay.
Relay K06
————————————————————————————————————————————————————————————
B158673
Relay stuck in closed
Actuator Stuck Closed
Trailer Body lights power
supply always ON
Relay K19 is damaged
Diagnostic Service 14. No additional
action is needed.
Replace relay.
Relay K19
————————————————————————————————————————————————————————————
B158773
Relay stuck in closed
Actuator Stuck Closed
Extra Spot Lamps power supply always ON
Relay K10 is damaged
Diagnostic Service 14. No additional action is needed.
Replace relay.
Relay K10
————————————————————————————————————————————————————————————
B158873
Relay stuck in closed
Actuator Stuck Closed
Beacon Warning Lamps
power supply always ON
Relay K13 is damaged
Diagnostic Service 14. No additional
action is needed.
Replace relay.
Relay K13
————————————————————————————————————————————————————————————
B158973
Relay stuck in closed
Actuator Stuck Closed
Roof Light Sign power
supply always ON
Relay K12 is damaged
Diagnostic Service 14. No additional
action is needed.
Replace relay.
Relay K12
————————————————————————————————————————————————————————————
B158A73
Relay stuck in closed
Actuator Stuck Closed
Full beam inside sign area power supply always ON
Relay K15 is damaged
Diagnostic Service 14. No additional action is needed.
Replace relay.
Relay K15
————————————————————————————————————————————————————————————
B158B73
Relay stuck in closed
Actuator Stuck Closed
TECU power supply always ON
Relay K17 is damaged
Diagnostic Service 14. No additional action is needed.
Replace relay.
Relay K17
————————————————————————————————————————————————————————————
B158C72
Relay stuck in
opened
Actuator Stuck Open
Loss of Refrigerator power
supply
Relay K02 is damaged
Diagnostic Service 14. No additional
action is needed.
Replace relay.
Relay K02
————————————————————————————————————————————————————————————
B158C73
Relay stuck in closed
Actuator Stuck Closed
Refrigerator power supply
always ON
Relay K02 is damaged
Diagnostic Service 14. No additional
action is needed.
Replace relay.
Relay K02
————————————————————————————————————————————————————————————
B158D72
Relay stuck in opened
Actuator Stuck Open
None
Relay K01 is damaged
Diagnostic Service 14. No additional action is needed.
Replace relay.
Relay K01
————————————————————————————————————————————————————————————
B158D73
Relay stuck in closed
Actuator Stuck Closed
None
Relay K01 is damaged
Diagnostic Service 14. No additional
action is needed.
Replace relay.
Relay K01
————————————————————————————————————————————————————————————
B158E73
Relay stuck in closed
Actuator Stuck Closed
None
Relay K26 is damaged
Diagnostic Service 14. No additional
action is needed.
Replace relay.
Relay K26
————————————————————————————————————————————————————————————
B158F73
Relay stuck in closed
Actuator Stuck Closed
None
Relay K18 is damaged
Diagnostic Service 14. No additional action is needed.
Replace relay.
Relay K18
————————————————————————————————————————————————————————————
B159072
Relay stuck in
opened
Actuator Stuck Open
None
Relay K23 is damaged
Diagnostic Service 14. No additional
action is needed.
Replace relay.
Relay K23
————————————————————————————————————————————————————————————
B159073
Relay stuck in closed
Actuator Stuck Closed
None
Relay K23 is damaged
Diagnostic Service 14. No additional action is needed.
Replace relay.
Relay K23
————————————————————————————————————————————————————————————
B150B11
Cab component backlight has been shorted to ground.
Circuit Short To Ground
Not possible to use the Dash/Body Builder/Bunk/Headershelf backlight illumination.
1. Wiring harness faulty
2. Actuator faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check backlight illumination
3. Check VMCU
Cab/Body Builder Backlight Circuit
————————————————————————————————————————————————————————————
B15B723
Hazard Button Signal Stuck Low for more than a configurable time.
(Default 5 minutes)
Signal Stuck Low
Not possible to activate/deactivate hazard warning.
Hazard button mechanically stuck in pressed position or electrical fault
in the button circuitry (short circuit to ground)
Diagnostic Service 14. No additional action is needed.
Repair/replace hazard warning button.
Hazard Button Circuit
————————————————————————————————————————————————————————————
B150A11
Hazard button backlight has been shorted to ground.
Circuit Short To Ground
Not possible to use the Hazard Button backlight illumination.
“1. Wiring harness faulty
2. Actuator faulty
3. VMCU faulty”
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check actuator
3. Check VMCU
Hazard Button Backlight Circuit
————————————————————————————————————————————————————————————
B151712
Headlight washer pump relay coil has been shorted to
battery.
Circuit Short To Battery
Not possible to use the Head Lamp Washer.
1. Headlight washer pump relay faulty
2. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check headlight washer pump relay (K16)
2. Check VMCU
Relay K16 Head Lamp Washer Pump Circuit
————————————————————————————————————————————————————————————
B151714
Headlight washer pump relay coil has been shorted to ground or open
circuit.
Circuit Short To Ground or Open
Not possible to use the Head Lamp Washer.
1. Headlight washer pump relay faulty
2. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check headlight washer pump relay (K16)
2. Check VMCU
Relay K16 Head Lamp Washer Pump Circuit
————————————————————————————————————————————————————————————
B100011
Redundant hazard output has been shorted to ground.
Circuit Short To Ground
Hazard indication on the hardwired output not possible.
1. Wiring harness faulty
2. Actuator faulty
3. VMCU faulty”
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check hazard switch and/or ELCP, if present
3. Check VMCU
Redundant Hazard Output Circuit
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
————————————————————————————————————————————————————————————
B100015
Redundant hazard output has been shorted to battery or
open circuit.
Circuit Short To Battery or Open
Hazard indication on the hardwired output not possible.
1. Wiring harness faulty
2. Actuator faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check hazard switch and/or ELCP, if present
3. Check VMCU
Redundant Hazard Output Circuit
————————————————————————————————————————————————————————————
U300A62
Invalid combination detected on the VMCU ignition key inputs.
Signal Compare Failure
Not possible to start the engine or use the vehicle.
1. Ignition key switch faulty.
2. Ignition key wiring harness to VMCU faulty.
Diagnostic Service 14. No additional action is needed.
1. Check ignition key switch
2. Check wires and connectors
Key Position
————————————————————————————————————————————————————————————
B152511
Cab max light 1 has been shorted to ground
Circuit Short To Ground
Not possible to use the left Roof light in the Headliner.
1. Wiring harness faulty 2. Actuator faulty 3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check actuator
3. Check VMCU
Max Light Circuit 1
————————————————————————————————————————————————————————————
B152512
Cab max light 1 has been shorted to battery
Circuit Short To Battery
Not possible to use the left Roof light in the Headliner.
1. Wiring harness faulty 2. Actuator faulty 3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check actuator
3. Check VMCU
Max Light Circuit 1
————————————————————————————————————————————————————————————
B152611
Cab max light 2 has been shorted to ground
Circuit Short To Ground
Not possible to use the right Roof light in the Headliner.
1. Wiring harness faulty 2. Actuator faulty 3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check actuator
3. Check VMCU
Max Light Circuit 2
————————————————————————————————————————————————————————————
B152612
Cab max light 2 has been shorted to battery
Circuit Short To Battery
Not possible to use the right Roof light in the Headliner.
1. Wiring harness faulty 2. Actuator faulty 3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check actuator
3. Check VMCU
Max Light Circuit 2
————————————————————————————————————————————————————————————
B152711
Cab resting light 1 has been shorted to
ground
Circuit Short To Ground
Not possible to use the Front Shelf Light (white
light).
1. Wiring harness faulty 2. Actuator faulty 3. VMCU
faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check actuator
3. Check VMCU
Resting Light Circuit 1
————————————————————————————————————————————————————————————
B152712
Cab resting light 1 has been shorted to
battery
Circuit Short To Battery
Not possible to use the Front Shelf Light (white
light)
1. Wiring harness faulty 2. Actuator faulty 3. VMCU
faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check actuator
3. Check VMCU
Resting Light Circuit 1
————————————————————————————————————————————————————————————
B152811
Cab resting light 2 has been shorted to
ground
Circuit Short To Ground
Not possible to use the left/right Catwalk Light
(white light).
1. Wiring harness faulty 2. Actuator faulty 3. VMCU
faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check actuator
3. Check VMCU
Resting Light Circuit 2
————————————————————————————————————————————————————————————
B152911
Cab night driving light has been shorted to ground
Circuit Short To Ground
Not possible to use the left/right Catwalk Light (red light) and Front Shelf Light
(red light).
1. Wiring harness faulty 2. Actuator faulty 3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check actuator
3. Check VMCU
Night Driving Light Circuit
————————————————————————————————————————————————————————————
B150E12
Main beam in roof sign relay coil has been shorted to battery.
Circuit Short To Battery
Not possible to use the Main Beam in the Roof Sign.
1. Main beam in roof sign relay faulty
2. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check main beam in roof sign relay (K15)
2. Check VMCU
Relay K15 Main Beam in Roof Sign Circuit
————————————————————————————————————————————————————————————
B150E14
Main beam in roof sign relay coil has been shorted to ground or open circuit.
Circuit Short To Ground or Open
Not possible to use the Main Beam in the Roof Sign.
1. Main beam in roof sign relay faulty
2. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check main beam in roof sign relay (K15)
2. Check VMCU
Relay K15 Main Beam in Roof Sign Circuit
————————————————————————————————————————————————————————————
U010000
Signal from EMS missing
No Sub Type Information
EMS diagnostic warnings and functional messages affected
Note: This DTC can be set as a secondary DTC which has been agreed in deviation D- 950. It can be triggered at the same time as: U300316 and U300317.
Connector or harness problems.
Problem with sending ECU.
Diagnostic Service 14. No additional action is needed.
Check wires and connectors between ECU and EMS. If this is the only lost communication DTC then fault is more probable to be close to the EMS.
This fault can also appear by incorrect calibration.
Lost Communication with EMS
————————————————————————————————————————————————————————————
U114000
– No message received from APM
No Sub Type Information
No communication between APM and VMCU. No park brake information received.
– No power supply to APM
– Broken CAN link
Diagnostic Service 14. No additional action is needed.
1a. Check battery
1b. Check power supply system
2a. Check CAN wires and connectors 2b. Check ECUs
Lost Communication With APM
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
————————————————————————————————————————————————————————————
P007011
<0,15V
Circuit Short To Ground
Not possible to determine ambient air temperature
1. Connected component broken.
2. Wires broken. Insulation damage.
3. Intermittent failure due
to poor connection.
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check connected sensors
3. Check ECUs
Ambient Air Temperature Sensor “A”
————————————————————————————————————————————————————————————
P007015
4,622V < U < 5V OR
U = 5V
Circuit Short To Battery or Open
Not possible to determine ambient air temperature
1. Connected component broken.
2. Wires broken. No continuity or insulation damage.
3. Intermittent failure due
to poor connection.
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check connected sensors
3. Check ECUs
Ambient Air Temperature Sensor “A”
————————————————————————————————————————————————————————————
P007016
0,15V <= U < 0,3V
Circuit Voltage Below Threshold
Not possible to determine ambient air temperature
1. Connected component broken.
Diagnostic Service 14. No additional action is needed.
1. Check connected sensors
2. Check ECUs
Ambient Air Temperature Sensor “A”
————————————————————————————————————————————————————————————
P012011
Accelerator pedal power supply 1 has been shorted to
ground.
Circuit Short To Ground
Accelerator Pedal Sensor #2 is used to calculate the accelerator pedal position.
1. Wiring harness faulty
2. Actuator faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check accelerator pedal
3. Check VMCU
Throttle/Pedal Position Sensor “A”
————————————————————————————————————————————————————————————
P012015
Accelerator pedal power supply 1 has been shorted to battery or open
circuit.
Circuit Short To Battery or Open
Accelerator Pedal Sensor #2 is used to calculate the accelerator pedal position.
1. Wiring harness faulty
2. Actuator faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check accelerator pedal
3. Check VMCU
Throttle/Pedal Position Sensor “A”
————————————————————————————————————————————————————————————
P012034
Accelerator pedal sensor 1 signal is below operational range (Low fault range defined by parameter P1GF5).
Signal High Time Less Than Minimum
Accelerator Pedal Sensor #2 is used to calculate the accelerator pedal position.
1. Connector or wiring harness faulty
2. Accelerator pedal sensor 1 faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors 2a. Check for a loose connection 2b. Check accelerator pedal
3a. Check for a loose connection 3b. Check VMCU
Throttle/Pedal Position Sensor “A”
————————————————————————————————————————————————————————————
P012035
Accelerator pedal sensor 1 signal is above operational range (High fault range defined by parameter P1GF6).
Signal High Time Greater Than Maximum
Accelerator Pedal Sensor #2 is used to calculate the accelerator pedal position.
1. Connector or wiring harness faulty
2. Accelerator pedal sensor 1 faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors 2a. Check for a loose connection 2b. Check accelerator pedal
3a. Check for a loose connection 3b. Check VMCU
Throttle/Pedal Position Sensor “A”
————————————————————————————————————————————————————————————
U015600
– No message received from HMIIOM
No Sub Type Information
No communication between HMIIOM and VMCU or between HMIIOM and IC.
– No power supply to HMIIOM
– Broken CAN link
Diagnostic Service 14. No additional action is needed.
1a. Check battery
1b. Check power supply system
2a. Check CAN wires and connectors 2b. Check ECUs
Lost Communication With HMIIOM
————————————————————————————————————————————————————————————
P022011
Accelerator pedal power supply 2 has been shorted to
ground.
Circuit Short To Ground
Accelerator Pedal Sensor #1 is used to calculate the accelerator pedal position.
1. Wiring harness faulty
2. Actuator faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check accelerator pedal
3. Check VMCU
Throttle/Pedal Position Sensor/Switch “B” Circuit
————————————————————————————————————————————————————————————
P022015
Accelerator pedal power supply 2 has been shorted to battery or open
circuit.
Circuit Short To Battery or Open
Accelerator Pedal Sensor #1 is used to calculate the accelerator pedal position.
1. Wiring harness faulty
2. Actuator faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check accelerator pedal
3. Check VMCU
Throttle/Pedal Position Sensor/Switch “B” Circuit
————————————————————————————————————————————————————————————
P022034
Accelerator pedal sensor 2 signal is below operational range (Low fault range defined by parameter P1GF7).
Signal High Time Less Than Minimum
Accelerator Pedal Sensor #1 is used to calculate the accelerator pedal position.
1. Connector or wiring harness faulty
2. Accelerator pedal sensor 2 faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors 2a. Check for a loose connection 2b. Check accelerator pedal
3a. Check for a loose connection 3b. Check VMCU
Throttle/Pedal Position Sensor/Switch “B” Circuit
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
————————————————————————————————————————————————————————————
P022035
Accelerator pedal sensor 2 signal is above operational range (High fault range defined by parameter P1GF8).
Signal High Time Greater Than Maximum
Accelerator Pedal Sensor #1 is used to calculate the accelerator pedal position.
1. Connector or wiring harness faulty
2. Accelerator pedal sensor 2 faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors 2a. Check for a loose connection 2b. Check accelerator pedal
3a. Check for a loose connection 3b. Check VMCU
Throttle/Pedal Position Sensor/Switch “B” Circuit
————————————————————————————————————————————————————————————
P213562
Deviation in accelerator pedal sensor values.
Signal Compare Failure
Accelerator Pedal Sensor (#1 or #2) with the lowest value is used to calculate the accelerator pedal position.
1. Wiring harness from accelerator pedal sensor faulty
2. Accelerator pedal sensor faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors 2a. Check for a loose connection 2b. Check accelerator pedal
3a. Check for a loose connection 3b. Check VMCU
Throttle/Pedal Position Sensor/Switch “A”/”B” Voltage Correlation
————————————————————————————————————————————————————————————
P215B61
Output shaft speed calculated by VMCU out of range (calculated value is more than 8000 rpm).
Signal Calculation Failure
Output Shaft Speed backup signal is set to Error (backup signal is always sent for vehicles without Tachograph. For vehicles with Tachograph the backup signal is sent when no output shaft speed is received from the Tachograph).
1.Wiring harness from speed sensor faulty.
2. Speed sensor faulty.
3. Incorrect VMCU dataset or VMCU faulty.
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check speed sensor 3a. Reload VMCU SW 3b. Check VMCU
Vehicle Speed – Output Shaft Speed Correlation
————————————————————————————————————————————————————————————
P215A61
Vehicle speed calculated by VMCU out of range (calculated value is more than 250 km/h).
Signal Calculation Failure
Vehicle Speed backup signal is set to Error (backup signal is always sent for vehicles without Tachograph. For vehicles with Tachograph the backup signal is sent when no vehicle speed is received from the Tachograph).
1. Wiring harness from speed sensor faulty.
2. Speed sensor faulty.
3. With TCO: TCO/VMCU K factor synchronization failure (VMCU/TCO faulty). 4: Without TCO: Incorrect K factor in VMCU.
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check speed sensor
3. Reload VMCU and TCO SW
4. Reload VMCU SW
Vehicle Speed – Wheel Speed Correlation
————————————————————————————————————————————————————————————
P215A62
Vehicle speed calculated by VMCU deviates more than 10 km/h (parameter) from TCO vehicle speed.
Signal Compare Failure
Vehicle Speed signal is untrustable if the Tachograph vehicle speed is the cause for the deviation.
1. Wiring harness from TCO faulty.
2. TCO/VMCU K factor synchronization failure (VMCU/TCO faulty).
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors 2a. Recalibrate K-factor
2b. Reload VMCU and TCO SW
Vehicle Speed – Wheel Speed Correlation
————————————————————————————————————————————————————————————
P215A64
Vehicle speed deviates more than 10 km/h (parameter) from road speed (applicable for vehicles with ABS/EBS).
Vehicle speed below or equal 0 km/h (parameter) while driveline is engaged and engine speed above 1200 rpm (parameter) (applicable for vehicles without ABS/EBS).
Signal Plausibility Failure
Vehicle Speed signal is set to Error.
1. Wiring harness from speed sensor faulty.
2. Speed sensor faulty.
3. With TCO: Incorrect W/K factor in TCO.
4: Without TCO: Incorrect K factor in VMCU.
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check speed sensor 3a. Reload TCO SW 3b. Reload VMCU SW
4. Reload VMCU SW
Vehicle Speed – Wheel Speed Correlation
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
————————————————————————————————————————————————————————————
U031744
At least one NVM parameter is
– in incorrect relation with one or more other parameters
– out of the allowed minimal and maximal values from the NVM parameter descriptor table
Data Memory Failure
For APM, the following effect can be seen:
No regeneration
No compressor control Safety valve cut off.
No EPB functions Pneumatic release of PB is possible by 29.2 port
No TX messages on CAN
– Incorrect/Unrealistic data written into APM
– APM HW damage
Diagnostic Service 14. No additional action is needed.
1. Reload APM SW
2. Check APM
Software Incompatibility With Park Brake Control Module
————————————————————————————————————————————————————————————
U031746
If not permitted internal variable is used
Calibration / Parameter Memory Failure
For APM, the following effect can be seen:
No regeneration
No compressor control Safety valve cut off.
No EPB functions Pneumatic release of PB is possible by 29.2 port
No TX messages on CAN
Damaged dataset Dataset doesn’t fit to the software
Damaged software or damaged APM (microcontroller)
Diagnostic Service 14. No additional action is needed.
1 – 2. Reload APM SW
3. Check APM
Software Incompatibility With Park Brake Control Module
————————————————————————————————————————————————————————————
U03174A
Drive software incompatible with the hardware
Incorrect Component Installed
For APM, the following effect can be seen:
No regeneration
No compressor control Safety valve cut off.
No EPB functions Pneumatic release of PB is possible
No TX messages on CAN
Wrong software version downloaded in APM
Diagnostic Service 14. No additional action is needed.
Reload APM SW
Software Incompatibility With Park Brake Control Module
————————————————————————————————————————————————————————————
U012B00
– No message received from FCIOM
No Sub Type Information
No communication between FCIOM and VMCU. No information about ambient air temperature can be received.
– No power supply to FCIOM
– Broken CAN link
Diagnostic Service 14. No additional action is needed.
1a. Check battery
1b. Check power supply system
2a. Check CAN wires and connectors 2b. Check ECUs
Lost Communication With Chassis Control Module “B” (FCIOM)
————————————————————————————————————————————————————————————
U015500
– No message received from IC
No Sub Type Information
No communication between IC and VMCU.
– No power supply to IC
– Broken CAN link
Diagnostic Service 14. No additional action is needed.
1a. Check battery
1b. Check power supply system
2a. Check CAN wires and connectors 2b. Check ECUs
Lost Communication With Instrument Panel Cluster (IPC) Control Module
————————————————————————————————————————————————————————————
C100E01
Failure is set if both parking brake sensor shorted to ground or Ubat.
General Electrical Failure
Backup Level 3. Autorelease not available XPR not available Autopark is not available Safe operation of the parking brake in driving is not guaranteed
Trailer test not available. Parking brake actuation status is not available.
1. Damage of the pressure sensor wiring
2. Damage of the pressure sensors
3. Damage of the APM
Diagnostic Service 14. No additional action is needed.
1. Replace APM
Parking Brake Circuit
————————————————————————————————————————————————————————————
C100E62
Parking brake sensors are not correlating, faulty sensor cannot be identified or AD conversion failure.
Signal Compare Failure
Backup level 3. Autorelease not available XPR not available Autopark is not available Safe operation of the parking brake in driving is not guaranteed
Trailer test not available. Parking brake actuation status is not available.
1. Leakage into the parking brake
2. Damage of the pressure sensor wiring
3. Damage of the pressure sensors
4. Damage of the APM
5. Incorrect supply voltage level
Diagnostic Service 14. No additional action is needed.
1. Check the Trailer control module;
2. Check leakages in the parking brake connection to the Trailer control module;
3. Check leakages in the parking brake connection to the springbrake chambers;
4. Check the APM exhaust ports;
5. Compare value of DID P1E0K to value of manometer connected to port 29.2;
6. Compare value of DID P1E0J to value of manometer connected to port 28.1/28.2;
7. Replace Parking brake relay valve;
8. Replace APM
Parking Brake Circuit
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
————————————————————————————————————————————————————————————
C100E64
Parking brake control pressure is lower than the reference pressure minus 1bar and Parking brake chamber pressure is lower than the reference pressure minus 1bar.
Signal Plausibility Failure
No functional effect. Risk of unintended braking due to low pressure in parking brake
1. Trailer Control Module or its control line is damaged or other trailer control port is not plugged
2. Trailer Control Module supply line is damaged.
3. Spring brake lines are damaged.
4. Parking brake relay valve failure
5. Sensor failure
6. APM internal valve failure
Diagnostic Service 14. No additional action is needed.
1. Check the Trailer control module;
2. Check Spring brake lines;
3. Check Parking brake relay valve;
4. Check the APM exhaust ports;
5. Check Parking brake sensor;
6. Replace APM
Parking Brake Circuit
————————————————————————————————————————————————————————————
C100E7A
Parking brake control and chamber pressure higher than the reference pressure minus threshold, this threshold is based on multicriteria formula.
Fluid Leak or Seal Failure
No functional effect. Risk of unintended release due to high pressure in parking brake.
1. Trailer control module or its pipe connection is damaged or incorrect trailer control port is not plugged
2. Trailer control module supply line is damaged.
3. Spring brake lines are damaged.
4. Parking brake relay valve failure
5. Sensor failure
6. APM internal valve failure
Diagnostic Service 14. No additional action is needed.
– Fill up the system to cut off, apply and release the parking brake manually
– Check the Trailer control module
– Check parking brake connection to the Trailer control module
– Check parking brake connection to the springbrake chambers
– Check the APM exhaust ports
– Compare value of DID P1E0K to value of manometer connected to port 29.2
– Compare value of DID P1E0J to value of manometer connected to port 28.1/28.2
– Replace Parking brake relay valve
– Replace APM
Parking Brake Circuit
————————————————————————————————————————————————————————————
U114161
Total vehicle distance calculated by VMCU out of range (> 21055406 km).
Signal Calculation Failure
Incorrect odometer distance.
1. Without TCO: Incorrect distance offset configured in VMCU (if VMCU is replaced, a distance offset can be loaded in the replacement VMCU)
2. With TCO: TCO faulty (distance data from TCO is “in range” followed by “out of range”, causes VMCU backup to be used and fault code to be set)
3. With/without TCO: VMCU faulty (incorrect stored distance (out of range value) or software fault)
4. With/without TCO: Actual distance which the vehicle has travelled is out of range
Diagnostic Service 14. No additional action is needed.
1. Reload SW
2. Check TCO
3a. Reload VMCU SW 3b. Check VMCU
4. No action
High Resolution Total Vehicle Distance
————————————————————————————————————————————————————————————
U114261
Trip distance calculated by VMCU out of range (> 21055406 km).
Signal Calculation Failure
Incorrect trip distance.
“1. Power loss when trip counter is reset
2. VMCU faulty (incorrect stored distance when trip
counter is reset)”
Diagnostic Service 14. No additional action is needed.
Reset trip meter, make a key Off/On reset and clear DTC. If the fault remains, replace VMCU.
High Resolution Trip Distance
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
————————————————————————————————————————————————————————————
B159F64
Deviation in VMCU primary and secondary storage of vehicle distance data.
Signal Plausibility Failure
None. The largest stored odometer distance will be used.
“1. Power loss when writing data to primary and/or secondary storage
1. VMCU faulty (incorrect stored distance in primary and/or secondary storage)”
Diagnostic Service 14. No additional action is needed.
1. Check battery and power supply system
2. Check VMCU
Stored Total Vehicle Distance Data
————————————————————————————————————————————————————————————
B150411
Position lights have been shorted to ground.
Circuit Short To Ground
Not possible to use the Position Lights or Identification Lights on
Roof.
1. Wiring harness faulty
2. Actuator faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check actuator and/or ELCP
3. Check VMCU
Position Light Circuit
————————————————————————————————————————————————————————————
B150412
Position lights have been shorted to battery.
Circuit Short To Battery
Not possible to use the Position Lights or Identification Lights on Roof.
1. Wiring harness faulty
2. Actuator faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check actuator and/or ELCP
3. Check VMCU
Position Light Circuit
————————————————————————————————————————————————————————————
B100311
Accessories power supply has been shorted to ground.
Circuit Short To Ground
Not possible to operate the DC/DC converter (24V to 12V) in the header shelf.
1. Wiring harness faulty
2. Actuator faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check actuator
3. Check VMCU
Accessories Power Supply
————————————————————————————————————————————————————————————
B100315
Accessories power supply has been shorted to battery or open circuit.
Circuit Short To Battery or Open
Not possible to operate the DC/DC converter (24V to 12V) in the header shelf.
1. Wiring harness faulty
2. Actuator faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check actuator
3. Check VMCU
Accessories Power Supply
————————————————————————————————————————————————————————————
B100711
Ignition power supply has been shorted to ground.
Circuit Short To Ground
Not possible to operate the Toll Collect System, Fuel Line Heater among many
other systems.
1. Wiring harness faulty
2. Actuator faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check ESCL and ignition key switch
3. Check VMCU
Ignition Signal Power Supply Circuit
————————————————————————————————————————————————————————————
B100715
Ignition power supply has been shorted to battery or open circuit.
Circuit Short To Battery or Open
Not possible to operate the Toll Collect System, Fuel Line Heater among many other systems.
1. Wiring harness faulty
2. Actuator faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check ESCL and ignition key switch
3. Check VMCU
Ignition Signal Power Supply Circuit
————————————————————————————————————————————————————————————
B150D12
EMS relay coil has been shorted to battery.
Circuit Short To Battery
No power supplied to the Engine Management System. Not possible to start or use the engine.
1. EMS relay faulty
2. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check EMS relay (K27)
2. Check VMCU
Relay K27 Engine Management System Power Circuit
————————————————————————————————————————————————————————————
B150D14
EMS relay coil has been shorted to ground or open
circuit.
Circuit Short To Ground or Open
No power supplied to the Engine Management System. Not possible to
start or use the engine.
1. EMS relay faulty
2. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check EMS relay (K27)
2. Check VMCU
Relay K27 Engine Management System Power Circuit
————————————————————————————————————————————————————————————
B150F12
Ignition relay coil has
been shorted to battery.
Circuit Short To Battery
No power supplied to the
Supplementary Restrain System (SRS).
1. Ignition relay faulty
2. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check ignition relay (K22)
2. Check VMCU
Relay K22 Ignition Power Supply Circuit
————————————————————————————————————————————————————————————
B150F14
Ignition relay coil has been shorted to ground or open
circuit.
Circuit Short To Ground or Open
No power supplied to the Supplementary Restrain System (SRS).
1. Ignition relay faulty
2. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check ignition relay (K22)
2. Check VMCU
Relay K22 Ignition Power Supply Circuit
————————————————————————————————————————————————————————————
B151012
BB ignition relay coil has been shorted to battery.
Circuit Short To Battery
No power supplied to the BBEC Ignition terminals.
1. BB ignition relay faulty
2. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check body builder ignition relay (K20)
2. Check VMCU
Relay K20 Body Builder Ignition Power Supply Circuit
————————————————————————————————————————————————————————————
B151014
BB ignition relay coil has been shorted to ground or open
circuit.
Circuit Short To Ground or Open
No power supplied to the BBEC Ignition terminals.
1. BB ignition relay faulty
2. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check body builder ignition relay (K20)
2. Check VMCU
Relay K20 Body Builder Ignition Power Supply Circuit
————————————————————————————————————————————————————————————
B151112
Power supply 2 relay coil has been shorted to battery.
Circuit Short To Battery
No power supplied to the BBEC Main and Switch terminals.
1. Power supply 2 relay faulty
2. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check power supply circuit relay 2 (K07)
2. Check VMCU
Relay K07 Power Supply 2 Circuit
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
————————————————————————————————————————————————————————————
B151114
Power supply 2 relay coil has been shorted to ground or open circuit.
Circuit Short To Ground or Open
No power supplied to the BBEC Main and Switch terminals.
1. Power supply 2 relay faulty
2. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check power supply circuit relay 2 (K07)
2. Check VMCU
Relay K07 Power Supply 2 Circuit
————————————————————————————————————————————————————————————
B151212
Power supply 3 relay coil has been shorted to battery.
Circuit Short To Battery
No power supplied to the Alcolock system, Cigarette Lighter or 24V Power
Outlets.
1. Power supply 3 relay faulty
2. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check power supply circuit relay 3 (K14)
2. Check VMCU
Relay K14 Power Supply 3 Circuit
————————————————————————————————————————————————————————————
B151214
Power supply 3 relay coil has been shorted to ground or open circuit.
Circuit Short To Ground or Open
No power supplied to the Alcolock system, Cigarette Lighter or 24V Power Outlets.
1. Power supply 3 relay faulty
2. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check power supply circuit relay 3 (K14)
2. Check VMCU
Relay K14 Power Supply 3 Circuit
————————————————————————————————————————————————————————————
B151312
Power supply 4 relay coil has been shorted to battery.
Circuit Short To Battery
Not possible to use the Bed light side walls, luggage compartment switches and lamps or the DC/DC converter (24V to 12V) in the header shelf.
1. Power supply 4 relay faulty
2. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check power supply circuit relay 4 (K11)
2. Check VMCU
Relay K11 Power Supply 4 Circuit
————————————————————————————————————————————————————————————
B151314
Power supply 4 relay coil has been shorted to ground or open circuit.
Circuit Short To Ground or Open
Not possible to use the Bed light side walls, luggage compartment switches and lamps or the DC/DC converter (24V to 12V) in the header shelf.
1. Power supply 4 relay faulty
2. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check power supply circuit relay 4 (K11)
2. Check VMCU
Relay K11 Power Supply 4 Circuit
————————————————————————————————————————————————————————————
B151412
Refrigerator relay coil has been shorted to battery.
Circuit Short To Battery
Not possible to use the Fridge in the Cab.
1. Refrigerator relay faulty
2. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check refrigerator relay (K02)
2. Check VMCU
Relay K02 Refrigerator Power Supply Circuit
————————————————————————————————————————————————————————————
B151414
Refrigerator relay coil has been shorted to ground or open circuit.
Circuit Short To Ground or Open
Not possible to use the Fridge in the Cab.
1. Fuse F75 blown
2. Refrigerator relay faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check fuse F75
2. Check refrigerator relay (K02)
3. Check VMCU
Relay K02 Refrigerator Power Supply Circuit
————————————————————————————————————————————————————————————
B151612
Seat heating / Engine running relay coil has been shorted to battery.
Circuit Short To Battery
Not possible to use the Seat Heater.
1. Seat heating / Engine running relay faulty
2. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check engine running relay (K09)
2. Check VMCU
Relay K09 Seat Heating Power Supply Circuit
————————————————————————————————————————————————————————————
B151614
Seat heating / Engine running relay coil has been shorted to ground or open circuit.
Circuit Short To Ground or Open
Not possible to use the Seat Heater.
1. Seat heating / Engine running relay faulty
2. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check engine running relay (K09)
2. Check VMCU
Relay K09 Seat Heating Power Supply Circuit
————————————————————————————————————————————————————————————
B151D12
Accessory relay coil has been shorted to battery.
Circuit Short To Battery
Not possible to use the coffee maker.
1. Accessory relay faulty
2. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check accessories relay (K08)
2. Check VMCU
Relay K08 Accessory Power Supply Circuit
————————————————————————————————————————————————————————————
B151D14
Accessory relay coil has been shorted to ground or open
circuit.
Circuit Short To Ground or Open
Not possible to use the coffee maker.
1. Accessory relay faulty
2. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check accessories relay (K08)
2. Check VMCU
Relay K08 Accessory Power Supply Circuit
————————————————————————————————————————————————————————————
B156516
EMS fuse blown.
Circuit Voltage Below Threshold
No power supplied to the Engine Management System. Not possible to
start or use the engine.
Fuse F41 is blown.
Diagnostic Service 14. No additional action is needed.
Replace EMS fuse
Fuse F41
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
————————————————————————————————————————————————————————————
B152012
Sunroof motor 1 relay coil has been shorted to battery.
Circuit Short To Battery
Not possible to operate the Roof Hatch.
1. Sunroof motor 1 relay faulty
2. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check sunroof motor 1 relay (K04)
2. Check VMCU
Relay K04 Sunroof Motor 1 Circuit
————————————————————————————————————————————————————————————
B152014
Sunroof motor 1 relay coil has been shorted to ground or open circuit.
Circuit Short To Ground or Open
Not possible to operate the Roof Hatch.
1. Fuse F52 blown
2. Sunroof motor 1 relay faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check fuse F52
2. Check sunroof motor 1 relay (K04)
3. Check VMCU
Relay K04 Sunroof Motor 1 Circuit
————————————————————————————————————————————————————————————
B152112
Sunroof motor 2 relay coil has been shorted to battery.
Circuit Short To Battery
Not possible to operate the Roof Hatch.
1. Sunroof motor 2 relay faulty
2. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check sunroof motor 2 relay (K03)
2. Check VMCU
Relay K03 Sunroof Motor 2 Circuit
————————————————————————————————————————————————————————————
B152114
Sunroof motor 2 relay coil has been shorted to ground or open circuit.
Circuit Short To Ground or Open
Not possible to operate the Roof Hatch.
1. Fuse F52 blown
2. Sunroof motor 2 relay faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check fuse F52
2. Check sunroof motor 2 relay (K03)
3. Check VMCU
Relay K03 Sunroof Motor 2 Circuit
————————————————————————————————————————————————————————————
B151512
Seats movement relay coil has been shorted to battery.
Circuit Short To Battery
Not possible to use the electrical seat adjustment.
1. Seats movement relay faulty
2. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check seats movement relay (K24)
2. Check VMCU
Relay K24 Seat Adjustment Power Supply Circuit
————————————————————————————————————————————————————————————
B151514
Seats movement relay coil has been shorted to ground or open circuit.
Circuit Short To Ground or Open
Not possible to use the electrical seat adjustment.
1. Seats movement relay faulty
2. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check seats movement relay (K24)
2. Check VMCU
Relay K24 Seat Adjustment Power Supply Circuit
————————————————————————————————————————————————————————————
B15B016
Vehicle Speed Sensor Supply Voltage < 6 V
Circuit Voltage Below Threshold
For vehicles without Tachograph, vehicle speed information will not be available.
– Vehicle Speed Sensor or cable harness faulty.
– Vehicle Speed Sensor Supply Circuitry In VMCU
faulty
Diagnostic Service 14. No additional action is needed.
Check wires and connectors
Speed Pulse Sensor Power Supply Circuit
————————————————————————————————————————————————————————————
B150929
Unexpected ESCL motor power supply detected.
Signal invalid
Not possible to lock or unlock the Electrical Steering Column Lock.
1. VMCU / ESCL motor power supply wiring harness faulty 2. ESCL faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check ESCL
3. Check VMCU
Electronic Steering Column Lock
————————————————————————————————————————————————————————————
B150972
Maximum number of retries (P1CYX) reached for locking ESCL.
Actuator Stuck Open
Not possible to lock the Electrical Steering Column Lock.
ESCL faulty.
Diagnostic Service 14. No additional action is needed.
1. Check ESCL
Electronic Steering Column Lock
————————————————————————————————————————————————————————————
B150973
Maximum number of retries (P1CYX) reached for unlocking ESCL.
Actuator Stuck Closed
Not possible to unlock the Electrical Steering Column Lock.
1. Steering column jammed.
2. ESCL faulty.
Diagnostic Service 14. No additional action is needed.
1a. Turn steering wheel to a position that not jam the ESCL 1b. Check for other things that can jam the ESCL
2. Check ESCL
Electronic Steering Column Lock
————————————————————————————————————————————————————————————
B150993
Operation timeout of the ESCL.
No Operation
Not possible to lock or unlock the Electrical
Steering Column Lock.
1. ESCL wiring harness faulty.
2. ESCL faulty.
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check ESCL
Electronic Steering Column Lock
————————————————————————————————————————————————————————————
B15B968
Electrical Steering Column Lock locking/unlocking functionality not
enabled.
Event Information
Not possible to lock/unlock the Electrical Steering Column Lock.
Electrical Steering Column Lock parameter P1G20 is inactive.
Diagnostic Service 14. No additional action is needed.
Enable Electrical Steering Column Lock by setting parameter P1G20 to TRUE (Enabled)
Electrical Steering Column Lock Locking/Unlocking Disabled
————————————————————————————————————————————————————————————
B150311
ESCL motor power supply has been shorted to ground.
Circuit Short To Ground
Not possible to lock or unlock the Electrical Steering Column Lock.
1. Wiring harness faulty
2. ESCL faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check ESCL
3. Check VMCU
Electrical Steering Column Lock Supply Circuit
————————————————————————————————————————————————————————————
B150312
ESCL motor power supply has been shorted to battery.
Circuit Short To Battery
Not possible to lock or unlock the Electrical Steering Column Lock.
1. Wiring harness faulty
2. ESCL faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check ESCL
3. Check VMCU
Electrical Steering Column Lock Supply Circuit
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
————————————————————————————————————————————————————————————
B110129
MTCO fault translated: “”V-pulse output”
Signal invalid
Not possible to guarantee a legal use of the MTCO.
“1. B7 wiring harness faulty
2. VMCU faulty (to which B7 is connected)
3. MTCO faulty (Error at B7 output)”
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check VMCU
3. Check MTCO
Vehicle Speed Impulse
————————————————————————————————————————————————————————————
B15A200
MTCO fault translated: “KBD Error”
No Sub Type Information
Not possible to guarantee a legal use of the MTCO.
MTCO faulty (Keyboard error)
Diagnostic Service 14. No additional action is needed.
Check MTCO
Tachograph Keyboard Error
————————————————————————————————————————————————————————————
B15A308
MTCO fault translated: “PulseGen. COM”
Bus Signal / Message Failures
Not possible to guarantee a legal use of the MTCO.
“1. Speed sensor faulty
2. MTCO faulty (Error in sensor communcation))”
Diagnostic Service 14. No additional action is needed.
1. Check speed sensor
2. Check MTCO
Tachograph Speed Pulse Sensor
————————————————————————————————————————————————————————————
B15A34A
MTCO fault translated: “PulseGen. COM”
Incorrect Component Installed
Not possible to guarantee a legal use of the MTCO.
“1. Speed sensor faulty
2. MTCO faulty (Error in temp. Sensorkey / serialnumber / realtime signal)”
Diagnostic Service 14. No additional action is needed.
1. Check speed sensor 2a. Reload MTCO SW 2b. Check MTCO
Tachograph Speed Pulse Sensor
————————————————————————————————————————————————————————————
B15A400
MTCO fault translated: “DriveWithoutChart”
No Sub Type Information
No driver data can be registered since chart is missing.
“1. Chart not inserted in MTCO
2. MTCO faulty (Drive
without chart)”
Diagnostic Service 14. No additional action is needed.
1. Insert Chart into MTCO 2a. Reload MTCO SW
2b. Check MTCO
Tachograph Trip Without Chart
————————————————————————————————————————————————————————————
B15A500
MTCO fault translated: “Drawer Error”
No Sub Type Information
Not possible to guarantee a legal use of the MTCO.
“1. MTCO drawer tray blocked
2. MTCO faulty (Error when
opening the tray)”
Diagnostic Service 14. No additional action is needed.
Check MTCO
Tachograph Drawer Error
————————————————————————————————————————————————————————————
B15A600
MTCO fault translated: “Missing Chart Driver1”
No Sub Type Information
No driver data can be registered since chart is missing.
“1. Chart for Driver 1 missing
2. MTCO faulty (Chart Driver
1 missing)”
Diagnostic Service 14. No additional action is needed.
1. Insert Chart for driver 1 into MTCO 2a. Reload MTCO SW
2b. Check MTCO
Tachograph Driver 1 Chart Missing
————————————————————————————————————————————————————————————
B15A700
MTCO fault translated: “Missing Chart Driver2”
No Sub Type Information
No driver data can be registered since chart is missing.
“1. Chart for Driver 2 missing
2. MTCO faulty (Chart Driver
2 missing)”
Diagnostic Service 14. No additional action is needed.
1. Insert Chart for driver 2 into MTCO 2a. Reload MTCO SW
2b. Check MTCO
Tachograph Driver 2 Chart Missing
————————————————————————————————————————————————————————————
B15A800
MTCO fault
translated: “Chart Motion”
No Sub Type Information
Not possible to guarantee a legal use of the MTCO.
MTCO faulty (Chart motion)
Diagnostic Service 14. No additional action is needed.
1. Reload MTCO SW
2. Check MTCO
Tachograph Chart Motion
————————————————————————————————————————————————————————————
B15A900
MTCO fault translated: “V- recorder defective”
No Sub Type Information
Not possible to guarantee a legal use of the MTCO.
MTCO faulty (Error in recorder system)
Diagnostic Service 14. No additional action is needed.
1. Reload MTCO SW
2. Check MTCO
Tachograph Recording System Defective
————————————————————————————————————————————————————————————
B15AA00
MTCO fault translated: “MFS- recorder defective”
No Sub Type Information
Not possible to guarantee a legal use of the MTCO.
MTCO faulty (Error in duplicating recorder system)
Diagnostic Service 14. No additional action is needed.
1. Reload MTCO SW
2. Check MTCO
Tachograph Duplicating Recording System Defective
————————————————————————————————————————————————————————————
B15AB00
MTCO fault translated: “Recorder Liftsystem defective”
No Sub Type Information
Not possible to guarantee a legal use of the MTCO.
MTCO faulty (Error in recorder lifting system)
Diagnostic Service 14. No additional action is needed.
1. Reload MTCO SW
2. Check MTCO
Tachograph Recording Lifting System Defective
————————————————————————————————————————————————————————————
B15A001
MTCO fault translated: “Power supply”
General Electrical Failure
Not possible to guarantee a legal use of the MTCO.
“1. Power supply wiring harness.
2. MTCO faulty (power
supply interruption)”
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check MTCO
Tachograph
————————————————————————————————————————————————————————————
B15A008
MTCO fault translated: “Instrument COM”
Bus Signal / Message Failures
Not possible to guarantee a legal use of the MTCO.
MTCO faulty (no instrument communication)
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check MTCO
3. Check VMCU
Tachograph
————————————————————————————————————————————————————————————
B15A045
MTCO fault translated: “Program memory”
Program Memory Failure
Not possible to guarantee a legal use of the MTCO.
MTCO faulty (error in FRAM, RTC, I2C, watchdog, program memory)
Diagnostic Service 14. No additional action is needed.
1. Reload MTCO SW
2. Check MTCO
Tachograph
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
————————————————————————————————————————————————————————————
B15A087
“MTCO fault translated: “”CAN Other””
CAN message TCO1 timeout
KWP2000 request
timeout”
Missing Message
Not possible to guarantee a legal use of the MTCO.
“1. Backbone 1 wiring harness faulty
2. ECU failure (any ECU connected to Backbone 1 network)
3. MTCO faulty (other CAN
problems)”
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check other ECUs
3. Check MTCO
Tachograph
————————————————————————————————————————————————————————————
B15A100
MTCO fault
translated: “LCD Error”
No Sub Type Information
Not possible to guarantee a legal use of the MTCO.
MTCO faulty (Display error)
Diagnostic Service 14. No additional action is needed.
Check MTCO
Tachograph Display Error
————————————————————————————————————————————————————————————
B15AC00
MTCO fault translated: “Adjustment Clock
request”
No Sub Type Information
Not possible to guarantee a legal use of the MTCO.
MTCO faulty (Time difference between display and chart carrier)
Diagnostic Service 14. No additional action is needed.
1. Reload MTCO SW
2. Check MTCO
Tachograph Display And Chart Time Inconsistent
————————————————————————————————————————————————————————————
B15BA00
MTCO fault translated: “Over Speed Warning”
No Sub Type Information
Not possible to guarantee a legal use of the MTCO.
1. Vehicle is actually travelling over speed limits.
2. Calibration problems.
3. Faulty vehicle speed sensors.
Diagnostic Service 14. No additional action is needed.
None. Speed limit has been exceeded.
Tachograph Over Speed Warning
————————————————————————————————————————————————————————————
B15B412
TECU power supply has been shorted to battery.
Circuit Short To Battery
Not possible to deactivate the transmission ECU.
1. TECU relay faulty
2. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Change TECU relay (K17)
2. Check VMCU
Relay K17 TECU Power Supply Circuit
————————————————————————————————————————————————————————————
B15B414
TECU power supply has been shorted to ground or open
circuit.
Circuit Short To Ground or Open
Not possible to activate the transmission ECU.
1. TECU relay faulty
2. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Change TECU relay (K17)
2. Check VMCU
Relay K17 TECU Power Supply Circuit
————————————————————————————————————————————————————————————
U300041
– ECU ROM
checksum error.
General Checksum Failure
Software is invalidated, reprogramming is required.
– ECU SW has been tampered
– ECU faulty (non volatile
memory)
Diagnostic Service 14. No additional action is needed.
1. Reload VMCU SW
2. Check VMCU HW
Electronic control unit
————————————————————————————————————————————————————————————
U114461
Vehicle speed calculated by VMCU out of range (calculated value is more than 250 km/h).
Signal Calculation Failure
Calculated vehicle speed is set to Error (calculated vehicle speed is always used for vehicles without Tachograph. For vehicles with Tachograph the calculated vehicle speed is used in fallback mode.
Fallback mode is entered when no vehicle speed is received from the Tachograph).
1. Wiring harness from speed sensor faulty.
2. Speed sensor faulty.
3. With TCO: TCO/VMCU K factor synchronization failure (VMCU/TCO faulty). 4: Without TCO: Incorrect K factor in VMCU.
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check speed sensor
3. Reload VMCU and TCO SW
4. Reload VMCU SW
Wheel Based Vehicle Speed
————————————————————————————————————————————————————————————
U114462
Vehicle speed calculated by VMCU deviates more than 10 km/h (parameter) from TCO vehicle speed.
Signal Compare Failure
Calculated vehicle speed is untrustable (for vehicles with Tachograph the calculated vehicle speed is used in fallback mode.
Fallback mode is entered when no vehicle speed is received from the Tachograph).
1. Wiring harness from TCO faulty.
2. TCO/VMCU K factor synchronization failure (VMCU/TCO faulty).
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Reload VMCU and TCO SW
Wheel Based Vehicle Speed
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
————————————————————————————————————————————————————————————
U114464
Vehicle speed deviates more than 10 km/h (parameter) from road speed (applicable for vehicles with ABS/EBS).
Vehicle speed below or equal 0 km/h (parameter) while driveline is engaged and engine speed above 1200 rpm (parameter) (applicable for vehicles without ABS/EBS).
Signal Plausibility Failure
Vehicle Speed signal is set to Error.
1. Wiring harness from speed sensor faulty.
2. Speed sensor faulty.
3. With TCO: Incorrect W/K factor in TCO.
4: Without TCO: Incorrect K factor in VMCU.
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check speed sensor
3. Reload TCO SW
4. Reload VMCU SW
Wheel Based Vehicle Speed
————————————————————————————————————————————————————————————
U114561
Output shaft speed calculated by VMCU out of range (calculated value is more than 8000 rpm).
Signal Calculation Failure
Calculated output shaft speed is set to Error (calculated output shaft speed is always used for vehicles without Tachograph. For vehicles with Tachograph the calculated output shaft speed is used in fallback mode. Fallback mode is entered when no output shaft speed is received from
the Tachograph).
1.Wiring harness from speed sensor faulty.
2. Speed sensor faulty.
3. Incorrect VMCU dataset or VMCU faulty.
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check speed sensor 3a. Reload VMCU SW 3b. Check VMCU
Transmission Output Shaft Speed
————————————————————————————————————————————————————————————
B151C11
Vehicle state for bodybuilder output has been shorted to ground.
Circuit Short To Ground
Not possible to operate power to the device connected to the BBEC. Output might be on always.
1. Wiring harness faulty
2. Actuator faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check connection/cable to CN11:3 on VMCU
2. Check VMCU
Vehicle State For Bodybuilder Circuit
————————————————————————————————————————————————————————————
B151C15
Vehicle state for bodybuilder output has been shorted to battery or open
circuit.
Circuit Short To Battery or Open
No power is supplied to the device connected to the BBEC. Output is probably always off.
1. Wiring harness faulty
2. Actuator faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check connection/cable to CN11:3 on VMCU
2. Check VMCU
Vehicle State For Bodybuilder Circuit
————————————————————————————————————————————————————————————
U000188
CAN Backbone 2 network fault.
Bus off
Vehicle cannot be used.
1. Backbone 2 wiring harness faulty
2. ECU failure (any ECU connected to Backbone 2
network)
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check ECUs
CAN Communication Backbone 2 Net
————————————————————————————————————————————————————————————
U001088
CAN Backbone 1 network fault.
Bus off
Vehicle cannot be used.
“1. Backbone 1 wiring harness faulty
2. ECU failure (any ECU connected to Backbone 1
network)”
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check ECUs
CAN Communication Backbone 1 Net
————————————————————————————————————————————————————————————
U006488
CAN Diagnostic Link network fault.
Bus off
Not possible to access the vehicle from an external Diagnostic Tool.
“1. Diagnostic Link wiring harness faulty
2. External test tool / hardware faulty
3. VMCU faulty (only VMCU is connected to this
network)”
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors 2a. Check test tool version
2b. Check HW
3. Check VMCU
CAN Communication Diagnostic Link Net
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
————————————————————————————————————————————————————————————
U300004
– Internal communication lost with high side and low side drivers.
– Communication error indicated by hardware
System Internal Failures
Vehicle cannot be used. Not possible to control any power supplies or relays from the VMCU/FRC.
– Defect VMCU hardware
– Defect VMCU software
Diagnostic Service 14. No additional action is needed.
1. Reload VMCU SW
2. Check VMCU HW
Electronic control unit
————————————————————————————————————————————————————————————
U002888
CAN Chassis network fault.
Bus off
Vehicle cannot be used.
“1. Chassis wiring harness faulty
2. ECU failure (any ECU connected to Chassis
network)”
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check ECUs
CAN Communication Chassis Net
————————————————————————————————————————————————————————————
U114649
VMCU LIN hardware fault.
Internal Electronic Failure
Rain Sensor cannot be used. Not possible to lock/unlock the Electrical Steering Column Lock.
1. VMCU faulty (BSW driver
/ transceiver).
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check VMCU
LIN7 Communication Net
————————————————————————————————————————————————————————————
U300316
– ECU Voltage < 16V.
Circuit Voltage Below Threshold
Supply sensitive diagnostics are inhibited. Depending on how low the supply voltage is, the vehicle can be affected in various ways.
Worst case it cannot be started or used. Best case it is not affected at all.
– Broken/bad power lines.
– Battery voltage too low.
Diagnostic Service 14. No additional action is needed.
1. Check battery
2. Check power supply system
Battery Power
————————————————————————————————————————————————————————————
U300317
– ECU Voltage > 32V.
Circuit Voltage Above Threshold
No functional impact.
– Alternator/charging circuit.
– External reason (charging or incorrect power supply).
Diagnostic Service 14. No additional action is needed.
Check power supply system
Battery Power
————————————————————————————————————————————————————————————
B15B116
– Voltage on VMCU Supply 1 Pin < 16V.
Circuit Voltage Below Threshold
Following functions cannot be used:
– Max Light 1
– Max Light 2
– Resting Light 1
2DO: Improve the names of these functions and features.
– Fuse F28 blown.
– Power supply or connector failure.
Diagnostic Service 14. No additional action is needed.
1. Replace fuse F28 2a. Check battery
2b. Check power supply system
Vehicle Master Control Unit Power Supply 1 Circuit
————————————————————————————————————————————————————————————
B15B216
– Voltage on VMCU Supply 2 Pin < 16V.
Circuit Voltage Below Threshold
Following functions cannot be used:
– Cab Body Working Light
– Side Reverse Working Lights
– Extra Spot Lamps Front
– Extra Parking Lights
– BB Flexible Switch 1
– BB Flexible Switch 2
– Tail Lift/Crane
– Backlight
– Resting Light 2
– Night Light
– Vehicle State For Body Builder
2DO: Improve the names of these functions and features.
– Fuse F27 blown.
– Power supply or connector failure.
Diagnostic Service 14. No additional action is needed.
1. Replace fuse F27 2a. Check battery
2b. Check power supply system
Vehicle Master Control Unit Power Supply 2 Circuit
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
————————————————————————————————————————————————————————————
B15B316
– Voltage on VMCU Supply 3 Pin < 16V.
Circuit Voltage Below Threshold
Following functions cannot be used:
– Hardwired Hazard Output
– Accelerator Pedal 1
– Accelerator Pedal 2
– Accessories Signal
– Ignition Signal
– Cab Tilt
– Position Light
– Electrical Steering Column Lock
– Hazard Switch Backlight
– Clutch Pedal Sensor/Switch
2DO: Improve the names of these functions and features.
– Fuse F68 blown.
– Power supply or connector failure.
Diagnostic Service 14. No additional action is needed.
1. Replace fuse F68 2a. Check battery
2b. Check power supply system
Vehicle Master Control Unit Power Supply 3 Circuit
————————————————————————————————————————————————————————————
U114688
LIN7 network fault (invalid / corrupted headers sent on LIN7).
Bus off
Rain Sensor cannot be used. Not possible to lock/unlock the Electrical Steering Column Lock.
1. LIN7 wiring harness faulty.
2. RAINS or ESCL faulty.
3. VMCU faulty.
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors 2a. Check RAINS
2b. Check ESCL
3. Check VMCU
LIN7 Communication Net
————————————————————————————————————————————————————————————
B152416
RAINS power supply below limit.
Fault Code Information (FCI) sent from RAINS: 22
Circuit Voltage Below Threshold
Rain Sensor cannot be used.
1. Wiring harness faulty (short circuit to ground).
2. CIOM faulty.
3. RAINS faulty.
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check CIOM
3. Check RAINS
Rain Sensor
————————————————————————————————————————————————————————————
B152417
RAINS power supply voltage above limit. Fault Code Information (FCI) sent from RAINS: 21
Circuit Voltage Above Threshold
Rain Sensor cannot be used.
1. Wiring harness faulty (short circuit to supply).
2. CIOM faulty.
3. RAINS faulty.
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check CIOM
3. Check RAINS
Rain Sensor
————————————————————————————————————————————————————————————
B152446
RAINS EEPROM
failure. Fault Code
Information (FCI) sent from RAINS: 19
Calibration / Parameter Memory Failure
Rain Sensor cannot be used.
1. Calibration data lost/corrupted in RAINS (try calibration).
2. RAINS faulty.
Diagnostic Service 14. No additional action is needed.
1. Recalibrate RAINS
2. Check RAINS
Rain Sensor
————————————————————————————————————————————————————————————
B152449
RAINS hardware failure.
Fault Code Information (FCI) sent (one or more) from RAINS: 5, 7, 8,
9, 11, 12, 13
Internal Electronic Failure
Rain Sensor cannot be used.
1. No EOL calibration done at supplier (RAINS faulty).
2. Twilight sensors defective (RAINS faulty).
3. Rain detection hardware faulty (RAINS faulty).
Diagnostic Service 14. No additional action is needed.
1. Recalibrate RAINS 2, 3. Check RAINS
Rain Sensor
————————————————————————————————————————————————————————————
B15244B
RAINS over temperature. Fault Code Information (FCI)
sent from RAINS: 20
Over Temperature
Rain Sensor cannot be used.
1. Ambient temperature too high.
2. RAINS faulty.
Diagnostic Service 14. No additional action is needed.
1. No action
2. Check RAINS
Rain Sensor
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
————————————————————————————————————————————————————————————
B152454
RAINS not calibrated at manufacturing. Fault Code Information (FCI) sent from RAINS: 10
Missing Calibration
Rains Sensor is not calibrated, degraded performance.
1. Missing 0km calibration data.
2. RAINS faulty.
Diagnostic Service 14. No additional action is needed.
1. Perform a calibration of the Rain Sensor using Routine Identifier R1AEZ.
2. Check RAINS
Rain Sensor
————————————————————————————————————————————————————————————
B152476
RAINS inproper installation to windscreen.
Fault Code Information (FCI) sent (one or more) from RAINS: 1, 2, 3,
4, 6
Wrong Mounting Position
Rain Sensor cannot be used.
1. Inproper optical contact to windscreen.
2. Incorrect windscreen properties.
3. RAINS faulty.
Diagnostic Service 14. No additional action is needed.
1. Adjust RAINS position
2. Recalibrate RAINS
3. Check RAINS
Rain Sensor
————————————————————————————————————————————————————————————
B152486
Faulty response from RAINS (invalid / corrupted response on RAINS headers sent on LIN7).
Signal Invalid
Rain Sensor cannot be used.
1. LIN7 wiring harness faulty.
2. RAINS faulty.
3. VMCU faulty.
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check RAINS
3. Check VMCU
Rain Sensor
————————————————————————————————————————————————————————————
B152487
No response from RAINS (no response on RAINS headers sent on LIN7).
Missing Message
Rain Sensor cannot be used.
1. LIN7 wiring harness faulty.
2. RAINS faulty.
3. VMCU faulty.
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check RAINS
3. Check VMCU
Rain Sensor
————————————————————————————————————————————————————————————
B152494
RAINS software failure.
Fault Code Information (FCI) sent from RAINS: 23
Unexpected Operation
Rain Sensor cannot be used.
1. Watchog reset (RAINS faulty).
Diagnostic Service 14. No additional action is needed.
Check RAINS
Rain Sensor
————————————————————————————————————————————————————————————
B150916
ESCL motor power supply below limit. Fault Code Information (FCI) sent (one or more) from ESCL: 7, 8, 11,
13
Circuit Voltage Below Threshold
Not possible to lock or unlock the Electrical Steering Column Lock.
1. System voltage too low.
2. Wiring harness faulty (short circuit to ground).
3. ESCL faulty.
4. VMCU faulty.
Diagnostic Service 14. No additional action is needed.
1a. Check battery
1b. Check power supply system
2. Check wires and connectors
3. Check ESCL
4. Check VMCU
Electronic Steering Column Lock
————————————————————————————————————————————————————————————
B150917
ESCL motor power supply above limit. Fault Code Information (FCI) sent (one or more) from ESCL: 1, 2, 3, 4,
9, 12, 14
Circuit Voltage Above Threshold
Not possible to lock or unlock the Electrical Steering Column Lock.
1. System voltage too high.
2. ESCL faulty.
Diagnostic Service 14. No additional action is needed.
1a. Check battery
1b. Check power supply system
2. Check ESCL
Electronic Steering Column Lock
————————————————————————————————————————————————————————————
B150918
ESCL motor current below limit.
Fault Code Information (FCI) sent from ESCL: 10
Circuit Current Below Threshold
Not possible to lock or unlock the Electrical Steering Column Lock.
1. Wiring harness faulty (too high impedance or bad connection)
2. VMCU faulty.
3. ESCL faulty.
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check ESCL
3. Check VMCU
Electronic Steering Column Lock
————————————————————————————————————————————————————————————
B150943
ESCL EEPROM
(special memory) failure.
Fault Code Information (FCI)
sent from ESCL: 18
Special Memory Failure
Not possible to lock or unlock the Electrical Steering Column Lock.
1. ESCL faulty.
Diagnostic Service 14. No additional action is needed.
1. Check ESCL
Electronic Steering Column Lock
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
————————————————————————————————————————————————————————————
B150944
ESCL RAM (data memory) failure. Fault Code Information (FCI)
sent from ESCL: 16
Data Memory Failure
Not possible to lock or unlock the Electrical Steering Column Lock.
1. ESCL faulty.
Diagnostic Service 14. No additional action is needed.
1. Check ESCL
Electronic Steering Column Lock
————————————————————————————————————————————————————————————
B150945
ESCL ROM (program memory) failure.
Fault Code Information (FCI) sent from ESCL: 17
Program Memory Failure
Not possible to lock or unlock the Electrical Steering Column Lock.
1. ESCL faulty.
Diagnostic Service 14. No additional action is needed.
1. Check ESCL
Electronic Steering Column Lock
————————————————————————————————————————————————————————————
B150948
ESCL supervision software (flag check, lock sequence) failure.
Fault Code Information (FCI) sent (one or more) from ESCL: 19, 20
Supervision Software Failure
Not possible to lock or unlock the Electrical Steering Column Lock.
1. ESCL faulty.
Diagnostic Service 14. No additional action is needed.
1. Check ESCL
Electronic Steering Column Lock
————————————————————————————————————————————————————————————
B150949
ESCL sensor defect. Fault Code Information (FCI) sent from ESCL: 21
Internal Electronic Failure
Not possible to lock or unlock the Electrical Steering Column Lock.
1. ESCL faulty.
Diagnostic Service 14. No additional action is needed.
1. Check ESCL
Electronic Steering Column Lock
————————————————————————————————————————————————————————————
B150954
ESCL not mathced to the vehicle.
Fault Code Information (FCI)
sent from ESCL: 23
Missing Calibration
Not possible to lock or unlock the Electrical Steering Column Lock.
1. ESCL still in virgin mode (try matching).
Diagnostic Service 14. No additional action is needed.
Match the Electrical Steering Column Lock to the vehicle using Routine Identifier R1AEY.
Electronic Steering Column Lock
————————————————————————————————————————————————————————————
B150961
ESCL detected incorrect authentication for unlock.
Fault Code Information (FCI)
sent from ESCL: 22
Signal Calculation Failure
Not possible to lock or unlock the Electrical Steering Column Lock.
1. ESCL faulty (encrypted communication key changed/corrupt).
2. VMCU faulty (encrypted communication key changed/corrupt).
Diagnostic Service 14. No additional action is needed.
1. Match ESCL
2. Reload VMCU SW
3. Check ESCL
Electronic Steering Column Lock
————————————————————————————————————————————————————————————
B150986
Faulty response from ESCL (invalid / corrupted response on RAINS headers sent on LIN7).
Signal Invalid
Not possible to lock or unlock the Electrical Steering Column Lock.
1. LIN7 wiring harness faulty.
2. ESCL faulty.
3. VMCU faulty.
Diagnostic Service 14. No additional action is needed.
1. Check wires and connectors
2. Check ESCL
3. Check VMCU
Electronic Steering Column Lock
————————————————————————————————————————————————————————————
B150987
No response from ESCL (no response on ESCL headers sent on LIN7).
Missing Message
Not possible to lock or unlock the Electrical Steering Column Lock.
1. LIN7 wiring harness faulty
2. CIOM / ESCL power supply wiring harness faulty
3. Backbone 2 wiring harness faulty (VMCU power supply command to CIOM)
4. ESCL faulty
5. CIOM faulty
6. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1 – 3. Check wires and connectors
4. Check ESCL
5. Check CIOM
6. Check VMCU
Electronic Steering Column Lock
————————————————————————————————————————————————————————————
U300044
ECU volatile memory error.
Data Memory Failure
VMCU does not work properly.
1. ECU faulty (volatile memory)
Diagnostic Service 14. No additional action is needed.
1. Reload VMCU SW
2. Check VMCU HW
Electronic control unit
————————————————————————————————————————————————————————————
U300045
ECU non volatile
memory error.
Program Memory
Failure
VMCU does not work
properly.
1. ECU faulty (non volatile
memory)
Diagnostic Service 14. No additional
action is needed.
1. Reload VMCU SW
2. Check VMCU HW
Electronic control unit
————————————————————————————————————————————————————————————
U300049
ECU internal hardware fault.
Internal Electronic Failure
VMCU does not work properly.
1. ECU faulty (BSW driver / transceiver).
2. Software error
Diagnostic Service 14. No additional action is needed.
1. Reload VMCU SW
2. Check VMCU HW
Electronic control unit
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
————————————————————————————————————————————————————————————
U300094
ECU watchdog fault.
Unexpected Operation
VMCU does not work properly.
1. ECU faulty (watchdog fault)
2. Software error
Diagnostic Service 14. No additional action is needed.
1. Reload VMCU SW
2. Check VMCU HW
Electronic control unit
————————————————————————————————————————————————————————————
U1FFF68
Factory mode parameter P1C54 is active
Event Information
A truck delivered with Factory mode active will have unspecified behavior that might influence customer safety.
Factory mode not disabled
Diagnostic Service 14. No additional action is needed.
Set P1C54 (Shared Factory mode parameter) for the ECU to FALSE before shipping from factory.
Factory Mode Active
————————————————————————————————————————————————————————————
U114768
Too many DTC for Diagnostic Warning Manger (DWM) to handle.
Event Information
No functional impact.
1. Refer to the DTC’s that are active.
Diagnostic Service 14. No additional action is needed.
According to other set DTCs.
DTC Notification Max Limit Reached
————————————————————————————————————————————————————————————
U250145
ECU has detected Internal Data Fragmentation and cannot save internal status information like DTCs.
Program Memory Failure
ECU cannot save internal data like new DTC
– Inproper shutdown – power cut
– In rare situations HW failure due to memory degradation
– Software error
Diagnostic Service 14. No additional action is needed.
Transfer data, run RID R1AHD, restore data may fix the problem
Internal Data Storage Fragmented
————————————————————————————————————————————————————————————
U250245
ECU detected Internal Data Storage Discarded, possibly discarding internal data but selfhealing attempted.
Program Memory Failure
No functional impact.
– Software error
– Memory degradation due to end-of-life
Diagnostic Service 14. No additional action is needed.
No action due to this DTC, the ECU has tried to recover. There are likely other DTCs that need to be handled as a consequence.
Internal Data Storage Discarded
————————————————————————————————————————————————————————————
B151A12
Windscreen wiper motor relay coil has been shorted to battery.
Circuit Short To Battery
Not possible to operate the wipers.
1. Windscreen wiper motor relay faulty
2. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check windscreen wiper motor On/Off relay (K05)
2. Check VMCU
Relay K05 Wiper Motor On/Off Circuit
————————————————————————————————————————————————————————————
B151A14
Windscreen wiper motor relay coil has been shorted to ground or open
circuit.
Circuit Short To Ground or Open
Not possible to operate the wipers.
1. Fuse F51 blown
2. Windscreen wiper motor relay faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check fuse F51
2. Check windscreen wiper motor On/Off relay (K05)
3. Check VMCU
Relay K05 Wiper Motor On/Off Circuit
————————————————————————————————————————————————————————————
B151B12
Windscreen wiper hi/lo relay coil has been shorted to
battery.
Circuit Short To Battery
Not possible to switch between low/high wiper speed.
1. Windscreen wiper hi/lo relay faulty
2. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check windscreen wiper Hi/Lo relay (K06)
2. Check VMCU
Relay K06 Wiper Motor High/Low Speed Circuit
————————————————————————————————————————————————————————————
B151B14
Windscreen wiper hi/lo relay coil has been shorted to ground or open circuit.
Circuit Short To Ground or Open
Not possible to switch between low/high wiper speed or not possible to operate the wipers.
1. Fuse F51 blown
2. Windscreen wiper hi/lo relay faulty
3. VMCU faulty
Diagnostic Service 14. No additional action is needed.
1. Check fuse F51
2. Check windscreen wiper Hi/Lo relay (K06)
3. Check VMCU
Relay K06 Wiper Motor High/Low Speed Circuit