B150214
24V Power supply lost (Fault Code Indication received from Window Antipinch).
Circuit Short To Ground or Open
Power window function is not working as expected.
1. Harness issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the Window Antipinch Module.
– Inspect the harness and connectors.
Window Antipinch Module
—————————————————————————————————————-
B150216
Window Antipinch measures 24V power supply voltage lower than 18,5 V (Fault Code Indication received from Window Antipinch).
Circuit Voltage Below Threshold
Power window function is not working as expected.
1. Harness issue;
2. Power supply circuit issue;
3. Faulty Window Antipinch hardware that misdetect the supply level.
Diagnostic Service 14. No additional action is needed.
– Inspect the Window Antipinch Module.
– Inspect the harness and connectors.
– Inspect the Door seal ageing.
Window Antipinch Module
—————————————————————————————————————-
B150217
Window Antippinch measures power supply voltage higher than 32V (Fault Code Indication received from Window Antipinch).
Circuit Voltage Above Threshold
Power window function is not working as expected.
1. Harness issue;
2. Power supply circuit issue;
3. Faulty Window Antipinch hardware that misdetect the supply level.
Diagnostic Service 14. No additional action is needed.
– Inspect the Window Antipinch Module.
– Inspect the harness and connectors.
– Inspect the Door seal ageing.
Window Antipinch Module
—————————————————————————————————————-
B15021C
Window Antipinch measures 12V power supply voltage lower than 7.5V or higher than 18,5V (Fault Code Indication received from Window Antipinch).
Circuit Voltage Out of Range
Power window function is not working as expected.
1. Harness issue;
2. Driver Door Module 12V output failure;
3. Faulty Window Antipinch hardware that misdetect the supply level.
Diagnostic Service 14. No additional action is needed.
– Inspect the Window Antipinch Module.
– Inspect the harness and connectors.
Window Antipinch Module
—————————————————————————————————————-
B150249
Window Antipinch internal fault (Fault Code Indication received from Window Antipinch).
Internal Electronic Failure
Power window function is not working as expected.
1. Internal uC failure detected;
2. Temperature sensor defective;
3. Hall sensor defective
Diagnostic Service 14. No additional action is needed.
– Replace the Window Antipinch Module.
Window Antipinch Module
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
—————————————————————————————————————-
B150254
Window position information is lost (Fault Code Indication received from Window Antipinch).
Missing Calibration
Power window function is not working as expected. Manual Up is working.
Manual Down is working. Auto-Down is working. Auto-Up is not working.
1. During a window motor movement the 12V or 24V power supply was suddenly interrupted;
2. Internal WindowAntipinch failure (Hall sensor error, Window moving while position counting not possible etc..);
3. Block event occured during reversal;
4. Window positon is unplausible;
5. Sealing ageing (that generated decalibration)
6. Change of door and glass type information sent over LIN during Window Antipinch run time.
Diagnostic Service 14. No additional action is needed.
– Perform the calibration (Press window up button until the window raise to the top and maintain it press for 3 seconds after that).
– Inspect the Door seal ageing.
Window Antipinch Module
—————————————————————————————————————-
B150255
No valid configuration information received from Driver Door Module over LIN:
– Glass Type
– Door Type (Fault Code
Indication received from Window Antipinch).
Not Configured
Power window function is not working as expected. Manual Up is working.
Manual Down is working. Auto-Down is working. Auto-Up is not working.
1. Harness issue;
2. Glass and door configuration information sent over LIN not available or error;
3. Change of door and glass type information sent over LIN during Window Antipinch run time.
Diagnostic Service 14. No additional action is needed.
– Inspect the harness and connectors.
– Redownload the Door Module Software.
– Contact back office.
Window Antipinch Module
—————————————————————————————————————-
B150271
Internal Window Antipinch relay is stuck (Fault Code Indication received from Window Antipinch).
Actuator Stuck
Power window function is not working as expected.
1. Mechanical defect of the relay contacts.
Diagnostic Service 14. No additional action is needed.
– Replace the Window Antipinch Module.
Window Antipinch Module
—————————————————————————————————————-
B150298
Window Motor is too hot according Window Antipinch overheating SW algorithm (LIN Fault Code Indication received from Window Antipinch).
Component or System Over Temperature
Window motor is inhibited by Window Antipinch.
Power window function is not working as expected, but returns to normal operation once the motor has cooled down.
1. Motor thermal protection is activated because motor was actived during too long time.
Diagnostic Service 14. No additional action is needed.
– Cool down the motor during 20 minutes minimum (Do not use it).
– Inspect the Door seal ageing.
Window Antipinch Module
—————————————————————————————————————-
U114286
Invalid frame
received from LIN slave.
Signal Invalid
Driver Door Module invalidates Window
Antipinch signals.
LIN slave issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the harness or connectors.
Window Antipinch Link
—————————————————————————————————————-
U114287
LIN slave not responding.
Missing Message
Driver Door Module invalidates Window Antipinch signals.
LIN slave issue. Harness issue.
Invalid parameters setting.
Diagnostic Service 14. No additional action is needed.
– Inspect the harness or connectors.
Window Antipinch Link
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
—————————————————————————————————————-
U114188
Communication fault detected
on the LIN bus.
Bus off
Driver Door Module invalidates Window Antipinch and Door Control Panel signals.
1. Harness issue: short circuit to GND/BAT/12V power supply or LIN bus is out of operational range: [8V..18V];
2. Issue on one of the LIN
nodes;
Diagnostic Service 14. No additional action is needed.
– Inspect the harness or connectors.
LIN8 Communication Net
—————————————————————————————————————-
B150316
Door Control Panel measures power supply voltage lower than 7.5V (Fault Code Indication received from Door Control Panel).
Circuit Voltage Below Threshold
All functions handled by Door Control Panel are not working as expected.
1. Harness issue;
2. Driver Door Module 12V output failure;
3. Faulty Door Control Panel hardware that misdetect the supply level.
Diagnostic Service 14. No additional action is needed.
– Inspect the Door Control Panel.
– Inspect the harness and connectors.
Driver Door Control Panel
—————————————————————————————————————-
B150317
Door Control Panel measures power supply voltage higher than 18.5V (Fault Code Indication received from Door Control Panel).
Circuit Voltage Above Threshold
All functions handled by Door Control Panel are not working as expected.
1. Harness issue;
2. Driver Door Module 12V output failure;
3. Faulty Door Control Panel hardware that misdetect the supply level.
Diagnostic Service 14. No additional action is needed.
– Inspect the Door Control Panel.
– Inspect the harness and connectors.
Driver Door Control Panel
—————————————————————————————————————-
B150344
Door Control Panel RAM check fail (Fault Code Indication received from Door Control Panel).
Data Memory Failure
Driver Door Module invalidates the Door Control Panel signals.
All functions handled by Door Control Panel are not working as expected.
1. Door Control Panel slave SW issue.
2. Door Control Panel RAM physical corruption.
Diagnostic Service 14. No additional action is needed.
– Replace the Door Control Panel.
Driver Door Control Panel
—————————————————————————————————————-
B150345
Door Control Panel ROM check fail (Fault Code Indication received from Door Control Panel).
Program Memory Failure
Driver Door Module invalidates the Door Control Panel signals.
All functions handled by Door Control Panel are not working as expected.
1. Door Control Panel ROM physical corruption.
Diagnostic Service 14. No additional action is needed.
– Replace the Door Control Panel.
Driver Door Control Panel
—————————————————————————————————————-
B150346
Door Control Panel flash corruption detected during writing of calibration data (Fault Code Indication received from Door Control Panel).
Calibration / Parameter Memory Failure
Driver Door Module invalidates the Door Control Panel signals.
All functions handled by Door Control Panel are not working as expected.
1. Door Control Panel flash memory corruption.
Diagnostic Service 14. No additional action is needed.
– Replace the Door Control Panel.
Driver Door Control Panel
—————————————————————————————————————-
B150349
Door Control Panel Buttons configuration failure (Fault Code Indication received from Door Control Panel).
Internal Electronic Failure
All functions handled by Door Control Panel are not working as expected.
1. Door Control Panel End Of Line configuration not correct.
Diagnostic Service 14. No additional action is needed.
– Replace the Door Control Panel.
Driver Door Control Panel
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
—————————————————————————————————————-
B150394
Door Control Panel unexpected SW operation executed; Door Control Panel slave watchdog reset performed;
Door Control Panel slave overrun situation detected; (Fault Code Indication received from Door Control Panel).
Unexpected Operation
Driver Door Module invalidates the Door Control Panel signals.
All functions handled by Door Control Panel are not working as expected.
1. Door Control Panel SW issue;
2. Door Control Panel MCU not correct.
Diagnostic Service 14. No additional action is needed.
– Replace the Door Control Panel.
Driver Door Control Panel
—————————————————————————————————————-
U114386
Invalid frame received from LIN slave.
Signal Invalid
Driver Door Module invalidates the Door Control Panel signals.
All functions handled by Door Control Panel are not working as expected.
LIN slave issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the Door Control Panel.
– Inspect the harness or connectors.
Driver Door Control Panel Link
—————————————————————————————————————-
U114387
LIN slave not responding.
Missing Message
Driver Door Module invalidates the Door Control Panel signals.
All functions handled by Door Control Panel are not working as expected.
LIN slave issue. Harness issue.
Invalid parameters setting.
Diagnostic Service 14. No additional action is needed.
– Inspect the Door Control Panel.
– Inspect the harness or connectors.
Driver Door Control Panel Link
—————————————————————————————————————-
B100011
Output pin short circuit to GND.
Circuit Short To Ground
Turns off Door Control Panel 12V power supply; All functions handled by Door Control Panel are not working as expected.
1. Harness issue.
2. DCP internal short circuit.
Diagnostic Service 14. No additional action is needed.
– Inspect the Door Control Panel.
– Inspect the harness or connectors.
Door Control Panel 12V power supply circuit
—————————————————————————————————————-
B100012
Output pin short circuit to BAT+.
Circuit Short To Battery
Turns off Door Control Panel 12V power supply; All functions handled by Door Control Panel are not working as expected.
1. Harness issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the Door Control Panel.
– Inspect the harness or connectors.
Door Control Panel 12V power supply circuit
—————————————————————————————————————-
B100013
Open circuit conditions detected on output pin.
Circuit Open
All functions handled by Door Control Panel are not working as expected.
1. Harness issue.
2. DCP internal failure.
Diagnostic Service 14. No additional action is needed.
– Inspect the Door Control Panel.
– Inspect the harness or connectors.
Door Control Panel 12V power supply circuit
—————————————————————————————————————-
B100016
Feedback voltage measured on the output is lower than 11,4V threshold (configurable).
Circuit Voltage Below Threshold
All functions handled by Door Control Panel may not work as expected.
1. Harness issue.
2. DDM internal HW issue.
3. DCP internal HW failure.
Diagnostic Service 14. No additional action is needed.
– Inspect the Door Control Panel.
– Inspect the harness or connectors.
Door Control Panel 12V power supply circuit
—————————————————————————————————————-
B100017
Feedback voltage measured on the output is higher 14V threshold
(configurable).
Circuit Voltage Above Threshold
All functions handled by Door Control Panel may not work as expected.
1. Harness issue.
2. DDM internal HW issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the Door Control Panel.
– Inspect the harness or connectors.
Door Control Panel 12V power supply circuit
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
—————————————————————————————————————-
B100111
Output pin short circuit to GND.
Circuit Short To Ground
Turns off Window Antipinch 12V power supply.
Power window function is not working as expected.
1. Harness issue. 2.Antipinch internal short circuit.
Diagnostic Service 14. No additional action is needed.
– Inspect the Window Antipinch Module.
– Inspect the harness or connectors.
Antipinch module 12V power supply circuit
—————————————————————————————————————-
B100112
Output pin short circuit to BAT+.
Circuit Short To Battery
Turns off Window Antipinch 12V power supply.
Power window function is not working as expected.
1. Harness issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the Window Antipinch Module.
– Inspect the harness or connectors.
Antipinch module 12V power supply circuit
—————————————————————————————————————-
B100113
Open circuit conditions detected on output pin.
Circuit Open
Power window function is not working as expected.
1. Harness issue.
2. Antipinch internal failure.
Diagnostic Service 14. No additional action is needed.
– Inspect the Window Antipinch Module.
– Inspect the harness or connectors.
Antipinch module 12V power supply circuit
—————————————————————————————————————-
B100116
Feedback voltage measured on the output is lower than 11,4V threshold (configurable).
Circuit Voltage Below Threshold
Power window function may not work as expected.
1. Harness issue.
2. DDM internal HW issue.
3. Antipinch internal HW failure.
Diagnostic Service 14. No additional action is needed.
– Inspect the Window Antipinch Module.
– Inspect the harness or connectors.
Antipinch module 12V power supply circuit
—————————————————————————————————————-
B100117
Feedback voltage measured on the output is higher 14V threshold (configurable).
Circuit Voltage Above Threshold
Power window function may not work as expected.
1. Harness issue.
2. DDM internal HW issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the Window Antipinch Module.
– Inspect the harness or connectors.
Antipinch module 12V power supply circuit
—————————————————————————————————————-
U005588
CAN Security failure detected.
Bus off
Driver Door Module does not communicate on CAN bus.
One or more functions of Driver Door Module are not working as expected.
1. Harness issue:
– Short circuit between CAN High & CAN low;
– Short circuit between CAN High & GND;
– Short circuit between CAN Low & BAT;
2. Issue on one of the CAN nodes connected to
Security subnet.
Diagnostic Service 14. No additional action is needed.
– Inspect the harness or connectors.
CAN Communication Security Net
—————————————————————————————————————-
U300005
Not supported SW configuration; Invalid parameters settings;
System Programming Failures
One or more functions of Driver Door Module are not working as expected.
1. SW release issue;
2. Not supported truck configuration build;
SW or HW complex system issue, to be rised to back- office.
Diagnostic Service 14. No additional action is needed.
– Replace the Driver Door Module Unit.
Electronic control unit
—————————————————————————————————————-
U300041
Flash memory HW failure.
General Checksum Failure
MSW invalidation after ECU reset: DTC reported by Primary Boot Loader.
Driver Door Module are not
working as expected
SW or HW complex system issue, to be rised to back- office.
Diagnostic Service 14. No additional action is needed.
– Replace the Driver Door Module Unit.
Electronic control unit
—————————————————————————————————————-
U300044
RAM corruption detected.
Data Memory Failure
ECU reset.
1. Invalid SW processing;
2. RAM corruption (intermittent fault due to working environment);
3. RAM physical issue (continuous defect);
SW or HW complex system issue, to be rised to back- office
Diagnostic Service 14. No additional action is needed.
– Replace the Driver Door Module Unit.
Electronic control unit
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
—————————————————————————————————————-
U300045
Program memory corruption.
Program Memory Failure
MSW invalidation after ECU reset.
Driver Door Module are not working as expected.
1. SWDL invalid process (cut of power during SWDL, etc)
2. Flash memory physical defect;
3. Invalid SW operation; SW or HW complex system issue, to be rised to back- office.
Diagnostic Service 14. No additional action is needed.
– Replace the Driver Door Module Unit.
Electronic control unit
—————————————————————————————————————-
U300046
Dataset memory corruption.
Calibration / Parameter Memory Failure
MSW invalidation after ECU reset.
Driver Door Module are not working as expected
1. Incorrect dataset download/change (e.g. cut of power during change).
2. Invalid SW operation (mainly in case of parameters change processing);
3. Flash memory physical defect;
SW or HW complex system issue, to be rised to back- office.
Diagnostic Service 14. No additional action is needed.
– Replace the Driver Door Module Unit.
Electronic control unit
—————————————————————————————————————-
U300049
Internal electronic failure.
Internal Electronic Failure
One or more functions of Driver Door Module are not working as expected.
Internal electronic failure:
– µC peripheric circuit invalid state;
– LIN tranceiver circuit broken;
– CAN tranceiver circuit broken;
SW or HW complex system issue, to be rised to back- office.
Diagnostic Service 14. No additional action is needed.
– Replace the Driver Door Module Unit.
Electronic control unit
—————————————————————————————————————-
U30004A
Power window function with antipinch activated on not valid HW. Electrical Power window function activated on not valid HW.
Incorrect Component Installed
Power window function is not working as expected.
Not correct component installed or not valid SW configuration downloaded. SW or HW complex system issue, to be rised to back- office.
Diagnostic Service 14. No additional action is needed.
– Contact back office.
Electronic control unit
—————————————————————————————————————-
U300055
No specific SW dataset downloaded.
Not Configured
One or more functions of Driver Door Module are not working as expected.
No valid SW configuration downloaded:
– no valid LIN schedule table selected through dataset
– no valid latch motor type selected through dataset
– no valid window motor type selected through dataset
– no valid mirror motor type selected through dataset SW or HW complex system issue, to be rised to back- office.
Diagnostic Service 14. No additional action is needed.
– Contact back office.
Electronic control unit
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
—————————————————————————————————————-
U300094
SW unexpected behaviour:
Unexpected Operation
ECU reset.
1. SW bug;
– unexpected SW operation executed;
– watchdog reset performed;
– overrun situation detected;
– unsynchronized communication circuit state detected;
2. RAM corruption;
3. Flash corruption;
SW or HW complex system issue, to be rised to back- office.
Diagnostic Service 14. No additional action is needed.
– Replace the Driver Door Module Unit.
Electronic control unit
—————————————————————————————————————-
U300316
Power supply voltage is lower than 16V (configurable).
Circuit Voltage Below Threshold
One or more functions of Driver Door Module are not working as expected.
1. Harness issue;
2. Power supply circuit issue;
3. ECU HW issue;
Diagnostic Service 14. No additional action is needed.
– Inspect the battery
– Inspect the Driver Door Module Unit.
– Inspect the harness and connectors.
Battery Power
—————————————————————————————————————-
U300317
Power supply voltage is higher than 32V (configurable).
Circuit Voltage Above Threshold
One or more functions of Driver Door Module are not working as expected.
1. Harness issue;
2. Power supply circuit issue;
3. ECU HW issue;
Diagnostic Service 14. No additional action is needed.
– Inspect the battery
– Inspect the Driver Door Module Unit.
– Inspect the harness and connectors.
Battery Power
—————————————————————————————————————-
U1FFF68
Factory Mode is
active in the ECU.
Event Information
No functional impact.
P1C54 parameter is set to
TRUE.
Diagnostic Service 14. No additional
action is needed.
Exit Factory mode.
Factory Mode Active
—————————————————————————————————————-
B100D13
Both lock & unlock signals stay in Open Circuit state longer than allowed (1500 ms configurable) after electrical lock or unlock request.
Circuit Open
if Open Circuit is on lock sensor :
-for a lock command, the latch will be lock and unlock 1s later.
-for an unlock command,the latch will be unlock.
if Open Circuit is on unlock sensor :
-for a lock command, the latch will be lock.
-for an unlock command,
the latch will be unlock.
1. Harness issue;
2. Latch failure;
Diagnostic Service 14. No additional action is needed.
– Inspect the Door Latch.
– Inspect the harness and connectors.
Door latch lock unlock sensors
—————————————————————————————————————-
B100411
Output pin short circuit to GND
Circuit Short To Ground
Locking function is not working as expected : For Lock command, it will not be executed.
For Unlock command, the
latch will be unlock.
1. Harness issue.
2. Actuator motor blown.
Diagnostic Service 14. No additional action is needed.
– Inspect the Door Latch.
– Inspect the harness and connectors.
Door latch actuator circuit 1
—————————————————————————————————————-
B100412
Output pin short circuit to BAT+
Circuit Short To Battery
Locking function is not working as expected : For Lock command, the latch will be lock
For Unlock command, it will
not be executed.
1. Harness issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the Door Latch.
– Inspect the harness and connectors.
Door latch actuator circuit 1
—————————————————————————————————————-
B100511
Output pin short circuit to GND.
Circuit Short To Ground
Locking function is not working as expected : For Lock command, the latch will be lock.
For Unlock command, it will
not be executed.
1. Harness issue.
2. Actuator motor blown.
Diagnostic Service 14. No additional action is needed.
– Inspect the Door Latch.
– Inspect the harness and connectors.
Door latch actuator circuit 2
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
—————————————————————————————————————-
B100512
Output pin short circuit to BAT+
Circuit Short To Battery
Locking function is not working as expected : For Lock command, it will not be executed.
For Unlock command, the
latch will be unlock.
1. Harness issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the Door Latch.
– Inspect the harness and connectors.
Door latch actuator circuit 2
—————————————————————————————————————-
B150513
Open circuit conditions detected on output pin.
Circuit Open
Locking function is not working as expected :
– for Lock command, it will not be executed.
– for Unlock command, it
will not be executed.
1. Harness issue.
2. Actuator motor blown.
Diagnostic Service 14. No additional action is needed.
– Inspect the Door Latch.
– Inspect the harness and connectors.
Door Latch Actuator Circuit
—————————————————————————————————————-
B100D11
Both lock & unlock signals stay in SC to ground state.
Circuit Short To Ground
Locking function is not working as expected :
– for Lock command, it will not be executed.
– for Unlock command, it
will not be executed.
1. Harness issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the Door Latch.
– Inspect the harness and connectors.
Door latch lock unlock sensors
—————————————————————————————————————-
B150712
Resident voltage level present when not expected by function.
Circuit Short To Battery
– if direct 24V short circuit with fuse, fuse or sensor will blow when door is open. If sensor has blown, door will always be considered as closed;
– if short circuit with protected output, this output will be affected when door is open (short to ground from concerned output perspective);
1. Harness issue;
2. Driver Door Module failure.
Diagnostic Service 14. No additional action is needed.
– Inspect the Door Latch.
– Inspect the harness and connectors.
Door Latch Open Sensor
—————————————————————————————————————-
B150812
Resident voltage level present when not expected by function.
Circuit Short To Battery
– if direct 24V short circuit with fuse, fuse or sensor will blow when door is locked.
If sensor has blown, door will always be considered as unlocked.
– if short circuit with protected output, this output will be affected when door is locked (short to ground from concerned output perspective);
1. Harness issue;
2. Driver Door Module failure.
Diagnostic Service 14. No additional action is needed.
– Inspect the Door Latch.
– Inspect the harness and connectors.
Door Latch Lock Sensor
—————————————————————————————————————-
B150912
Resident voltage level present when not expected by function.
Circuit Short To Battery
– if direct 24V short circuit with fuse, fuse or sensor will blow when door is unlocked.
If sensor has blown, door will always be considered as locked.
– if short circuit with protected output, this output will be affected when door is unlocked (short to ground from concerned output
perspective);
1. Harness issue;
2. Driver Door Module failure
Diagnostic Service 14. No additional action is needed.
– Inspect the Door Latch.
– Inspect the harness and connectors.
Door Latch Unlock Sensor
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
—————————————————————————————————————-
B100211
Output pin short circuit to GND.
Circuit Short To Ground
Switch off output until :
1. Next Vehicle Mode change from lower than Pre- Running to higher or equal to PreRunning
2. New activation request.
1. Harness issue.
2. Lamp mounting issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the lamp.
– Inspect the harness and connectors.
Door instep lamp circuit
—————————————————————————————————————-
B100212
Output pin short circuit to BAT+.
Circuit Short To Battery
Switch off output until :
1. Next Vehicle Mode change from lower than Pre- Running to higher or equal to PreRunning
2. New activation request.
1. Harness issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the lamp.
– Inspect the harness and connectors.
Door instep lamp circuit
—————————————————————————————————————-
B100213
Open circuit conditions detected on output pin.
Circuit Open
Switch off output until :
1. next Vehicle Mode change from lower than Pre- Running to higher or equal to PreRunning
2. New activation request.
1. Harness issue.
2. Lamp blown.
Diagnostic Service 14. No additional action is needed.
– Inspect the lamp.
– Inspect the harness and connectors.
Door instep lamp circuit
—————————————————————————————————————-
B100311
Output pin short circuit to GND.
Circuit Short To Ground
Switch off output until :
1. next Vehicle Mode change from lower than Pre- Running to higher or equal to PreRunning
2. New activation request.
1. Harness issue.
2. Lamp mounting issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the lamp.
– Inspect the harness and connectors.
Door warning lamp circuit
—————————————————————————————————————-
B100312
Output pin short circuit to BAT+.
Circuit Short To Battery
Switch off output until :
1. next Vehicle Mode change from lower than Pre- Running to higher or equal to PreRunning
2. New activation request.
1. Harness issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the lamp.
– Inspect the harness and connectors.
Door warning lamp circuit
—————————————————————————————————————-
B100313
Open circuit conditions detected on output pin.
Circuit Open
Switch off output until :
1. next Vehicle Mode change from lower than Pre- Running to higher or equal to PreRunning
2. New activation request.
1. Harness issue.
2. Lamp blown.
Diagnostic Service 14. No additional action is needed.
– Inspect the lamp.
– Inspect the harness and connectors.
Door warning lamp circuit
—————————————————————————————————————-
B100811
Output pin short circuit to GND.
Circuit Short To Ground
Mirror function is not working as expected.
1. Harness issue.
2. Actuator motor blown.
Diagnostic Service 14. No additional action is needed.
– Inspect the mirrors.
– Inspect the harness and connectors.
Mirrors adjustment actuators common circuit
—————————————————————————————————————-
B100812
Output pin short circuit to BAT+.
Circuit Short To Battery
Mirror function is not working as expected.
1. Harness issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the mirrors.
– Inspect the harness and connectors.
Mirrors adjustment actuators common circuit
—————————————————————————————————————-
B100911
Output pin short circuit to GND.
Circuit Short To Ground
Mirror function is not working as expected.
1. Harness issue.
2. Actuator motor blown.
Diagnostic Service 14. No additional action is needed.
– Inspect the mirrors.
– Inspect the harness and connectors.
Main Mirror X adjustment actuator circuit
—————————————————————————————————————-
B100912
Output pin short circuit to BAT+.
Circuit Short To Battery
Mirror function is not working as expected.
1. Harness issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the mirrors.
– Inspect the harness and connectors.
Main Mirror X adjustment actuator circuit
—————————————————————————————————————-
B100913
Open circuit conditions detected on output pin.
Circuit Open
Mirror function is not working as expected.
1. Harness issue.
2. Actuator motor blown.
Diagnostic Service 14. No additional action is needed.
– Inspect the mirrors.
– Inspect the harness and connectors.
Main Mirror X adjustment actuator circuit
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
—————————————————————————————————————-
B100919
Feedback load current measured on the output is higher than defined threshold.
Threshold depends on multiple criteria (voltage, temperature and motor type).
Circuit Current Above Threshold
Mirror function is not working as expected.
ECU switches off main and wide mirror motors outputs for 60 seconds.
1. Mirror actuator issue;
2. Mirror mechanical issue (anormal resistance).
Diagnostic Service 14. No additional action is needed.
– Inspect the mirrors.
– Inspect the harness and connectors.
Main Mirror X adjustment actuator circuit
—————————————————————————————————————-
B100A11
Output pin short circuit to GND
Circuit Short To Ground
Mirror function is not working as expected.
1. Harness issue.
2. Actuator motor blown.
Diagnostic Service 14. No additional action is needed.
– Inspect the mirrors.
– Inspect the harness and connectors.
Main Mirror Y adjustment actuator circuit
—————————————————————————————————————-
B100A12
Output pin short circuit to BAT+
Circuit Short To Battery
Mirror function is not working as expected.
1. Harness issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the mirrors.
– Inspect the harness and connectors.
Main Mirror Y adjustment actuator circuit
—————————————————————————————————————-
B100A13
Open circuit conditions detected on output pin.
Circuit Open
Mirror function is not working as expected.
1. Harness issue.
2. Actuator motor blown.
Diagnostic Service 14. No additional action is needed.
– Inspect the mirrors.
– Inspect the harness and connectors.
Main Mirror Y adjustment actuator circuit
—————————————————————————————————————-
B100A19
Feedback load current measured on the output is higher than defined threshold.
Threshold depends on multiple criteria (voltage, temperature and motor type).
Circuit Current Above Threshold
Mirror function is not working as expected.
1. Mirror actuator issue;
2. Mirror mechanical issue (anormal resistance).
Diagnostic Service 14. No additional action is needed.
– Inspect the mirrors.
– Inspect the harness and connectors.
Main Mirror Y adjustment actuator circuit
—————————————————————————————————————-
B100B11
Output pin short circuit to GND
Circuit Short To Ground
Mirror function is not working as expected.
1. Harness issue.
2. Actuator motor blown.
Diagnostic Service 14. No additional action is needed.
– Inspect the mirrors.
– Inspect the harness and connectors.
Wide Mirror X adjustment actuator circuit
—————————————————————————————————————-
B100B12
Output pin short circuit to BAT+.
Circuit Short To Battery
Mirror function is not working as expected.
1. Harness issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the mirrors.
– Inspect the harness and connectors.
Wide Mirror X adjustment actuator circuit
—————————————————————————————————————-
B100B13
Open circuit conditions detected on output pin.
Circuit Open
Mirror function is not working as expected.
1. Harness issue.
2. Actuator motor blown.
Diagnostic Service 14. No additional action is needed.
– Inspect the mirrors.
– Inspect the harness and connectors.
Wide Mirror X adjustment actuator circuit
—————————————————————————————————————-
B100B19
Feedback load current measured on the output is higher than defined threshold.
Threshold depends on multiple criteria (voltage, temperature and motor type).
Circuit Current Above Threshold
Mirror function is not working as expected.
1. Mirror actuator issue;
2. Mirror mechanical issue (anormal resistance).
Diagnostic Service 14. No additional action is needed.
– Inspect the mirrors.
– Inspect the harness and connectors.
Wide Mirror X adjustment actuator circuit
—————————————————————————————————————-
B100C11
Output pin short circuit to GND
Circuit Short To Ground
Mirror function is not working as expected.
1. Harness issue.
2. Actuator motor blown.
Diagnostic Service 14. No additional action is needed.
– Inspect the mirrors.
– Inspect the harness and connectors.
Wide Mirror Y adjustment actuator circuit
—————————————————————————————————————-
B100C12
Output pin short circuit to BAT+
Circuit Short To Battery
Mirror function is not working as expected.
1. Harness issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the mirrors.
– Inspect the harness and connectors.
Wide Mirror Y adjustment actuator circuit
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
—————————————————————————————————————-
B100C13
Open circuit conditions detected on output pin
Circuit Open
Mirror function is not working as expected.
1. Harness issue.
2. Actuator motor blown.
Diagnostic Service 14. No additional action is needed.
– Inspect the mirrors.
– Inspect the harness and connectors.
Wide Mirror Y adjustment actuator circuit
—————————————————————————————————————-
B100C19
Feedback load current measured on the output is higher than defined threshold.
Threshold depends on multiple criteria (voltage, temperature and motor type).
Circuit Current Above Threshold
Mirror function is not working as expected.
ECU switches off main and wide mirror motors outputs for 60 seconds.
1. Mirror actuator issue;
2. Mirror mechanical issue (anormal resistance).
Diagnostic Service 14. No additional action is needed.
– Inspect the mirrors.
– Inspect the harness and connectors.
Wide Mirror Y adjustment actuator circuit
—————————————————————————————————————-
B100611
Output pin short circuit to GND.
Circuit Short To Ground
Power window function is not working as expected.
– For window down request, window will be driven down.
– For window up request, it will not be executed.
1. Harness issue.
2. Actuator motor blown.
Diagnostic Service 14. No additional action is needed.
– Inspect the Power Window Motor.
– Inspect the harness and connectors.
Power window actuator circuit 1
—————————————————————————————————————-
B100612
Output pin short circuit to BAT+.
Circuit Short To Battery
Power window function is not working as expected.
– For window down request, it will not be executed.
– For window up request, window will be driven up.
1. Harness issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the Power Window Motor.
– Inspect the harness and connectors.
Power window actuator circuit 1
—————————————————————————————————————-
B100711
Output pin short circuit to GND.
Circuit Short To Ground
Power window function is not working as expected.
– For window down request, it will not be executed.
– For window up request, window will be driven up.
1. Harness issue.
2. Actuator motor blown.
Diagnostic Service 14. No additional action is needed.
– Inspect the Power Window Motor.
– Inspect the harness and connectors.
Power window actuator circuit 2
—————————————————————————————————————-
B100712
Output pin short circuit to BAT+.
Circuit Short To Battery
Power window function is not working as expected.
– For window down request, window will be driven down.
– For window up request, it will not be executed.
1. Harness issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the Power Window Motor.
– Inspect the harness and connectors.
Power window actuator circuit 2
—————————————————————————————————————-
B150613
Open circuit conditions detected on output pin
Circuit Open
Power window function is not working as expected.
– For window down request, it will not be executed.
– For window up request, it will not be executed.
1. Harness issue.
2. Actuator motor blown.
Diagnostic Service 14. No additional action is needed.
– Inspect the Power Window Motor.
– Inspect the Door seal ageing.
– Inspect the harness and connectors.
Power Window Motor
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
—————————————————————————————————————-
B150618
Feedback load current measured on the output is lower than defined threshold.
Threshold is dynamic and based on multicriteria formula (voltage, temperature and motor type).
Circuit Current Below Threshold
Power window function is not working as expected.
1. Anormal window mechanical resistance,
2. Power motor issue (Thermal switch open, etc)
3. Door sealing ageing.
Diagnostic Service 14. No additional action is needed.
– Inspect the Power Window Motor.
– Inspect the Door seal ageing.
– Inspect the harness and connectors.
Power Window Motor
—————————————————————————————————————-
B150619
Feedback load current measured on the output is higher than defined threshold.
Threshold is dynamic and based on multicriteria formula (voltage, temperature and motor type).
Circuit Current Above Threshold
Power window function is not working as expected.
1. Anormal window mechanical resistance,
2. Power motor issue,
3. Door sealing ageing.
Diagnostic Service 14. No additional action is needed.
– Inspect the Power Window Motor.
– Inspect the Door seal ageing.
– Inspect the harness and connectors.
Power Window Motor
—————————————————————————————————————-
U114668
Maximum number
of DTC reached: 29 DTC.
Event Information
No new DTC set until the
failure is removed or DTC list cleared.
1. Unexpected environment conditions;
2. ECU failure
Diagnostic Service 14. No additional action is needed.
– Clear all DTC.
DTC Notification Max Limit Reached
————————————————————————————————————————————————————————————
U005588
CAN Security failure detected.
Bus off
Passenger Door Module does not communicate on CAN bus.
One or more functions of Passenger Door Module are not working as expected.
1. Harness issue:
– Short circuit between CAN High & CAN low;
– Short circuit between CAN High & GND;
– Short circuit between CAN Low & BAT;
2. Issue on one of the CAN nodes connected to
Security subnet.
Diagnostic Service 14. No additional action is needed.
– Inspect the harness or connectors.
CAN Communication Security Net
————————————————————————————————————————————————————————————
U300005
Not supported SW configuration; Invalid parameters settings;
System Programming Failures
One or more functions of Passenger Door Module are not working as expected.
1. SW release issue;
2. Not supported truck configuration build;
SW or HW complex system issue, to be rised to back-
office.
Diagnostic Service 14. No additional action is needed.
– Replace the Passenger Door Module Unit.
Electronic control unit
————————————————————————————————————————————————————————————
U300041
Flash memory HW failure.
General Checksum Failure
MSW invalidation : DTC reported by Primary Boot Loader.
Passenger Door Module are not working as expected.
SW or HW complex system issue, to be rised to back- office.
Diagnostic Service 14. No additional action is needed.
– Replace the Passenger Door Module Unit.
Electronic control unit
————————————————————————————————————————————————————————————
U300044
RAM corruption detected.
Data Memory Failure
ECU reset.
1. Invalid SW processing;
2. RAM corruption (intermittent fault due to working environment);
3. RAM physical issue (continuous defect);
SW or HW complex system issue, to be rised to back- office .
Diagnostic Service 14. No additional action is needed.
– Replace the Passenger Door Module Unit.
Electronic control unit
————————————————————————————————————————————————————————————
U300045
Program memory corruption.
Program Memory Failure
MSW invalidation after ECU reset.
Passenger Door Module are not working as expected.
1. SWDL invalid process (cut of power during SWDL, etc)
2. Flash memory physical defect;
3. Invalid SW operation; SW or HW complex system issue, to be rised to back- office.
Diagnostic Service 14. No additional action is needed.
– Replace the Passenger Door Module Unit.
Electronic control unit
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
————————————————————————————————————————————————————————————
U300046
Dataset memory corruption.
Calibration / Parameter Memory Failure
MSW invalidation after ECU reset.
1. Incorrect dataset download/change (e.g. cut of power during change).
2. Invalid SW operation (mainly in case of parameters change processing);
3. Flash memory physical defect;
SW or HW complex system issue, to be rised to back- office.
Diagnostic Service 14. No additional action is needed.
– Replace the Passenger Door Module Unit.
Electronic control unit
————————————————————————————————————————————————————————————
U300049
Internal electronic failure.
Internal Electronic Failure
One or more functions of Passenger Door Module are not working as expected.
Internal electronic failure:
– µC peripheric circuit invalid state;
– LIN tranceiver circuit broken;
– CAN tranceiver circuit broken;
SW or HW complex system issue, to be rised to back- office.
Diagnostic Service 14. No additional action is needed.
– Replace the Passenger Door Module Unit.
Electronic control unit
————————————————————————————————————————————————————————————
U30004A
Power window function with antipinch activated on not valid HW. Electrical Power window function activated on not valid HW.
Incorrect Component Installed
Power window function is not working as expected.
Not correct component installed or not valid SW configuration downloaded. SW or HW complex system issue, to be rised to back- office.
Diagnostic Service 14. No additional action is needed.
– Contact back office.
Electronic control unit
————————————————————————————————————————————————————————————
U300055
No specific SW dataset downloaded.
Not Configured
One or more functions of Passenger Door Module are not working as expected.
No valid SW configuration downloaded: – no valid LIN schedule table selected through dataset – no valid latch motor type selected through dataset – no valid window motor type selected through dataset – no valid mirror motor type selected through dataset SW or HW complex system issue, to be rised to back- office.
Diagnostic Service 14. No additional action is needed.
– Contact back office.
Electronic control unit
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
————————————————————————————————————————————————————————————
U300094
SW unexpected behaviour;
Unexpected Operation
ECU reset.
1. SW bug;
– unexpected SW operation executed;
– watchdog reset performed;
– overrun situation detected;
– insynchronized communication circuit state detected;
2. RAM corruption;
3. Flash corruption;
SW or HW complex system issue, to be rised to back- office.
Diagnostic Service 14. No additional action is needed.
– Replace the Passenger Door Module Unit.
Electronic control unit
————————————————————————————————————————————————————————————
U300316
Power supply voltage is lower than 16V (configurable).
Circuit Voltage Below Threshold
One or more functions of Passsenger Door Module are not working as expected.
1. Harness issue;
2. Power supply circuit issue;
3. ECU HW issue;
Diagnostic Service 14. No additional action is needed.
– Inspect the battery
– Inspect the Passenger Door Module Unit.
– Inspect the harness and connectors.
Battery Power
————————————————————————————————————————————————————————————
U300317
Power supply voltage is higher than 32V (configurable).
Circuit Voltage Above Threshold
One or more functions of Passsenger Door Module are not working as expected.
1. Harness issue;
2. Power supply circuit issue;
3. ECU HW issue;
Diagnostic Service 14. No additional action is needed.
– Inspect the battery
– Inspect the Passenger Door Module Unit.
– Inspect the harness and connectors.
Battery Power
————————————————————————————————————————————————————————————
U1FFF68
Factory Mode is
active in the ECU.
Event Information
No functional impact.
P1C54 parameter is set to
TRUE.
Diagnostic Service 14. No additional
action is needed.
Exit Factory mode.
Factory Mode Active
————————————————————————————————————————————————————————————
U114668
Maximum number of DTC reached : 29 DTC.
Event Information
No new DTC set until the failure is removed or DTC list cleared.
1. Unexpected environment conditions;
2. ECU failure
Diagnostic Service 14. No additional action is needed.
– Clear All DTC.
DTC Notification Max Limit Reached
————————————————————————————————————————————————————————————
B100D13
Both lock & unlock signals stay in Open Circuit state longer than allowed (1500 ms configurable) after electrical lock or unlock request.
Circuit Open
if Open Circuit is on lock sensor :
-for a lock command, the latch will be lock and unlock 1s later.
-for an unlock command,the latch will be unlock.
if Open Circuit is on unlock sensor :
-for a lock command, the latch will be lock.
-for an unlock command,
the latch will be unlock.
1. Harness issue;
2. Latch failure;
Diagnostic Service 14. No additional action is needed.
– Inspect the Door Latch.
– Inspect the harness and connectors.
Door latch lock unlock sensors
————————————————————————————————————————————————————————————
B100411
Output pin short circuit to GND.
Circuit Short To Ground
Locking function is not working as expected :
– for Lock command, it will not be executed.
– for Unlock command, the
latch will be unlock.
1. Harness issue.
2. Actuator motor blown.
Diagnostic Service 14. No additional action is needed.
– Inspect the Door Latch.
– Inspect the harness and connectors.
Door latch actuator circuit 1
————————————————————————————————————————————————————————————
B100412
Output pin short circuit to BAT+.
Circuit Short To Battery
Locking function is not working as expected :
– for Lock command, it will not be executed.
– for Unlock command, the
latch will be unlock.
1. Harness issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the Door Latch.
– Inspect the harness and connectors.
Door latch actuator circuit 1
————————————————————————————————————————————————————————————
B100511
Output pin short circuit to GND.
Circuit Short To Ground
Locking function is not working as expected :
– for Lock command, the latch will be lock
– for Unlock command, it
will not be executed.
1. Harness issue.
2. Actuator motor blown.
Diagnostic Service 14. No additional action is needed.
– Inspect the Door Latch.
– Inspect the harness and connectors.
Door latch actuator circuit 2
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
————————————————————————————————————————————————————————————
B100512
Output pin short circuit to BAT+.
Circuit Short To Battery
Locking function is not working as expected :
– for Lock command, the latch will be lock
– for Unlock command, it
will not be executed.
1. Harness issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the Door Latch.
– Inspect the harness and connectors.
Door latch actuator circuit 2
————————————————————————————————————————————————————————————
B150513
Open circuit conditions detected on output pin.
Circuit Open
Locking function is not working as expected :
– for Lock command, it will not be executed.
– for Unlock command, it
will not be executed.
1. Harness issue.
2. Actuator motor blown.
Diagnostic Service 14. No additional action is needed.
– Inspect the Door Latch.
– Inspect the harness and connectors.
Door Latch Actuator Circuit
————————————————————————————————————————————————————————————
B100D11
Both lock & unlock signals stay in SC to ground state.
Circuit Short To Ground
Locking function is not working as expected :
– for Lock command, it will not be executed.
– for Unlock command, it
will not be executed.
1. Harness issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the Door Latch.
– Inspect the harness and connectors.
Door latch lock unlock sensors
————————————————————————————————————————————————————————————
B150712
Resident voltage level present when not expected by function.
Circuit Short To Battery
– if direct 24V short circuit with fuse, fuse or sensor will blow when door is open. If sensor has blown, door will always be considered as closed;
– if short circuit with protected output, this output will be affected when door is open (short to ground from concerned output perspective);
1. Harness issue;
2. Passenger Door Module failure.
Diagnostic Service 14. No additional action is needed.
– Inspect the Door Latch.
– Inspect the harness and connectors.
Door Latch Open Sensor
————————————————————————————————————————————————————————————
B150812
Resident voltage level present when not expected by function.
Circuit Short To Battery
– if direct 24V short circuit with fuse, fuse or sensor will blow when door is locked.
If sensor has blown, door will always be considered as unlocked.
– if short circuit with protected output, this output will be affected when door is locked (short to ground from concerned output perspective);
1. Harness issue.
2. Passenger Door Module failure.
Diagnostic Service 14. No additional action is needed.
– Inspect the Door Latch.
– Inspect the harness and connectors.
Door Latch Lock Sensor
————————————————————————————————————————————————————————————
B150912
Resident voltage level present when not expected by function.
Circuit Short To Battery
– if direct 24V short circuit with fuse, fuse or sensor will blow when door is unlocked.
If sensor has blown, door will always be considered as locked.
– if short circuit with protected output, this output will be affected when door is unlocked (short to ground from concerned output
perspective);
1. Harness issue;
2. Passenger Door Module failure.
Diagnostic Service 14. No additional action is needed.
– Inspect the Door Latch.
– Inspect the harness and connectors.
Door Latch Unlock Sensor
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
————————————————————————————————————————————————————————————
B150214
24V Power supply lost (Fault Code Indication received from Window Antipinch).
Circuit Short To Ground or Open
Power window function is not working as expected.
1. Harness issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the Window Antipinch Module.
– Inspect the harness and connectors.
Window Antipinch Module
————————————————————————————————————————————————————————————
B150216
Window Antipinch measures 24V power supply voltage lower than 18,5 V (Fault Code Indication reception from Window Antipinch).
Circuit Voltage Below Threshold
Power window function is not working as expected.
1. Harness issue;
2. Power supply circuit issue;
3. Faulty Window Antipinch hardware that misdetect the supply level.
Diagnostic Service 14. No additional action is needed.
– Inspect the Window Antipinch Module.
– Inspect the harness and connectors.
– Inspect the Door seal ageing.
Window Antipinch Module
————————————————————————————————————————————————————————————
B150217
Window Antipinch measures power supply voltage higher than 32V (Fault Code Indication received from Window Antipinch).
Circuit Voltage Above Threshold
Power window function is not working as expected.
1. Harness issue;
2. Power supply circuit issue;
3. Faulty Window Antipinch hardware that misdetect the supply level.
Diagnostic Service 14. No additional action is needed.
– Inspect the Window Antipinch Module.
– Inspect the harness and connectors.
– Inspect the Door seal ageing.
Window Antipinch Module
————————————————————————————————————————————————————————————
B15021C
Window Antipinch measures 12V power supply voltage lower than 7.5V or higher than 18,5V (Fault Code Indication received from Window Antipinch).
Circuit Voltage Out of Range
Power window function is not working as expected.
1. Harness issue;
2. PDM 12V output failure;
3. Faulty Window Antipinch hardware that misdetect the supply level.
Diagnostic Service 14. No additional action is needed.
– Inspect the Window Antipinch Module.
– Inspect the harness and connectors.
Window Antipinch Module
————————————————————————————————————————————————————————————
B150249
Window Antipinch internal fault (Fault Code Indication received from Window Antipinch)
Internal Electronic Failure
Power window function is not working as expected.
1. Internal uC failure detected;
2. Temperature sensor defective;
3. Hall sensor defective
Diagnostic Service 14. No additional action is needed.
– Replace the Window Antipinch Module.
Window Antipinch Module
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
————————————————————————————————————————————————————————————
B150254
Window position information is lost (Fault Code Indication received from Window Antipinch).
Missing Calibration
Power window function is not working as expected. Manual Up is working.
Manual Down is working. Auto-Down is working. Auto-Up is not working.
1. During a window motor movement the 12V or 24V power supply was suddenly interrupted;
2. Internal Window Antipinch failure (Hall sensor error, Window moving while position counting not possible etc..);
3. Block event occured during reversal;
4. Window positon is unplausible;
5. Sealing ageing (that generated decalibration)
6. Change of door and glass type information sent over LIN during Antipinch run time.
Diagnostic Service 14. No additional action is needed.
– Perform the calibration (Press window up button until the window raise to the top and maintain it press for 3 seconds after that).
– Inspect the Door seal ageing.
Window Antipinch Module
————————————————————————————————————————————————————————————
B150255
No valid configuration information received from Passenger Door Module over LIN:
– Glass Type
– Door Type (Fault Code
Indication received from Window Antipinch).
Not Configured
Power window function is not working as expected. Manual Up is working.
Manual Down is working. Auto-Down is working. Auto-Up is not working.
1. Harness issue;
2. Glass and door configuration information sent over LIN not available or error;
3. Change of door and glass type information sent over LIN during Window Antipinch run time.
Diagnostic Service 14. No additional action is needed.
– Inspect the harness and connectors.
– Redownload the Door Module Software.
– Contact back office.
Window Antipinch Module
————————————————————————————————————————————————————————————
B150271
Internal Window Antipinch relay is stuck (Fault Code Indication received from Window Antipinch).
Actuator Stuck
Power window function is not working as expected.
1. Mechanical defect of the relay contacts.
Diagnostic Service 14. No additional action is needed.
– Replace the Window Antipinch Module.
– Inspect the Door seal ageing.
Window Antipinch Module
————————————————————————————————————————————————————————————
B150298
Window Motor is too hot according Window Antipinch overheating SW algorithm (LIN Fault Code Indication received from Window Antipinch).
Component or System Over Temperature
Window motor is inhibited by Window Antipinch.
Power window function is not working as expected, but return automatically to normal operation once the motor has cooled down.
1. Motor thermal protection is activated because motor was actived during too long time.
Diagnostic Service 14. No additional action is needed.
– Cool down the motor during 20 minutes minimum (Do not use it).
– Inspect the Door seal ageing.
Window Antipinch Module
————————————————————————————————————————————————————————————
U114286
Invalid frame received from LIN slave.
Signal Invalid
Passenger Door Module Invalidates Window Antipinch signals.
LIN slave issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the harness or connectors.
Window Antipinch Link
————————————————————————————————————————————————————————————
U114287
LIN slave not responding.
Missing Message
Passenger Door Module Invalidates Window Antipinch signals.
LIN slave issue. Harness issue.
Invalid parameters setting.
Diagnostic Service 14. No additional action is needed.
– Inspect the harness or connectors.
Window Antipinch Link
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
————————————————————————————————————————————————————————————
U114488
Communication fault detected on the LIN bus.
Bus off
Passenger Door Module Invalidates Window Antipinch signals.
Passenger Door Module invalidates the Passenger Control Panel signals.
1. Harness issue: short circuit to GND/BAT/12V Power Supply or LIN bus is out of operational range: [8V..18V];
2. Issue on one of the LIN
nodes;
Diagnostic Service 14. No additional action is needed.
– Inspect the harness or connectors.
LIN9 Communication Net
————————————————————————————————————————————————————————————
U114586
Invalid frame received from LIN slave.
Signal Invalid
Passenger Door Module invalidates the Passenger Control Panel signals.
All functions handled by Passenger Control Panel are not working as expected.
LIN slave issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the Door Control Panel.
– Inspect the harness or connectors.
Passenger Door Control Panel Link
————————————————————————————————————————————————————————————
U114587
LIN slave not responding.
Missing Message
Passenger Door Module invalidates the Passenger Control Panel signals.
All functions handled by Passenger Control Panel are not working as expected.
LIN slave issue. Harness issue.
Invalid parameters setting.
Diagnostic Service 14. No additional action is needed.
– Inspect the Door Control Panel.
– Inspect the harness or connectors.
Passenger Door Control Panel Link
————————————————————————————————————————————————————————————
B150416
Door Control Panel measures power supply voltage lower than 7.5V(Fault Code Indication received from Door Control Panel).
Circuit Voltage Below Threshold
All functions handled by Door Control Panel are not working as expected.
1. Harness issue;
2. Passenger Door Module 12V output failure;
3. Faulty Door Control Panel hardware that misdetect the supply level.
Diagnostic Service 14. No additional action is needed.
– Inspect the Door Control Panel.
– Inspect the harness and connectors.
Passenger Door Control Panel
————————————————————————————————————————————————————————————
B150417
Door Control Panel measures power supply voltage higher than 18.5V (Fault Code Indication received from Door Control Panel).
Circuit Voltage Above Threshold
All functions handled by Door Control Panel are not working as expected.
1. Harness issue;
2. Passenger Door Module 12V output failure;
3. Faulty Door Control Panel hardware that misdetect the supply level.
Diagnostic Service 14. No additional action is needed.
– Inspect the Door Control Panel.
– Inspect the harness and connectors.
Passenger Door Control Panel
————————————————————————————————————————————————————————————
B150444
Door Control Panel RAM check fail (Fault Code Indication received from Door Control Panel).
Data Memory Failure
Passenger Door Module invalidates the Passenger Control Panel signals.
All functions handled by Passenger Control Panel are not working as expected.
1. Door Control Panel slave SW issue.
2. Door Control Panel RAM physical corruption.
Diagnostic Service 14. No additional action is needed.
– Replace the Door Control Panel.
Passenger Door Control Panel
————————————————————————————————————————————————————————————
B150445
Door Control Panel ROM check fail (Fault Code Indication received from Door Control Panel).
Program Memory Failure
Passenger Door Module invalidates the Passenger Control Panel signals.
All functions handled by Passenger Control Panel are not working as expected.
1. Door Control Panel ROM physical corruption.
Diagnostic Service 14. No additional action is needed.
– Replace the Door Control Panel.
Passenger Door Control Panel
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
————————————————————————————————————————————————————————————
B150446
Door Control Panel flash corruption detected during writing of calibration data (Fault Code Indication received from Door Control Panel).
Calibration / Parameter Memory Failure
Passenger Door Module invalidates the Passenger Control Panel signals.
All functions handled by Passenger Control Panel are not working as expected.
1. Door Control Panel flash memory corruption.
Diagnostic Service 14. No additional action is needed.
– Replace the Door Control Panel.
Passenger Door Control Panel
————————————————————————————————————————————————————————————
B150449
Door Control Panel Buttons configuration failure (Fault Code Indication received from Door Control Panel).
Internal Electronic Failure
All functions handles by Door Control Panel are not working as expected.
1. Door Control Panel End Of Line configuration not correct.
Diagnostic Service 14. No additional action is needed.
– Replace the Door Control Panel.
Passenger Door Control Panel
————————————————————————————————————————————————————————————
B150494
Door Control Panel unexpected SW operation executed; Door Control Panel slave watchdog reset performed;
Door Control Panel slave overrun situation detected; (Fault Code Indication received from Door Control Panel).
Unexpected Operation
Passenger Door Module invalidates the Passenger Control Panel signals.
All functions handled by Passenger Control Panel are not working as expected.
1. Door Control Panel SW issue;
2. Door Control Panel MCU not correct.
Diagnostic Service 14. No additional action is needed.
– Replace the Door Control Panel.
Passenger Door Control Panel
————————————————————————————————————————————————————————————
B100011
Output pin short circuit to GND.
Circuit Short To Ground
Turns off Door Control Panel 12V power supply; All functions handled by Door Control Panel are not working as expected.
1. Harness issue.
2. Door Control Panel internal short circuit.
Diagnostic Service 14. No additional action is needed.
– Inspect the Door Control Panel.
– Inspect the harness or connectors.
Door Control Panel 12V power supply circuit
————————————————————————————————————————————————————————————
B100012
Output pin short circuit to BAT+.
Circuit Short To Battery
Turns off Door Control Panel 12V power supply; All functions handled by Door Control Panel are not working as expected.
1. Harness issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the Door Control Panel.
– Inspect the harness or connectors.
Door Control Panel 12V power supply circuit
————————————————————————————————————————————————————————————
B100013
Open circuit conditions detected on output pin.
Circuit Open
All functions handled by Door Control Panel are not working as expected.
1. Harness issue.
2. Door Contrl Panel internal failure.
Diagnostic Service 14. No additional action is needed.
– Inspect the Door Control Panel.
– Inspect the harness or connectors.
Door Control Panel 12V power supply circuit
————————————————————————————————————————————————————————————
B100016
Feedback voltage measured on the output is lower than 11,4V threshold (configurable).
Circuit Voltage Below Threshold
All functions handled by Door Control Panel are not working as expected.
1. Harness issue.
2. Passenger Door Module internal HW issue.
3. Door Control Panel internal HW failure.
Diagnostic Service 14. No additional action is needed.
– Inspect the Door Control Panel.
– Inspect the harness or connectors.
Door Control Panel 12V power supply circuit
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
————————————————————————————————————————————————————————————
B100017
Feedback voltage measured on the output is higher 14V threshold
(configurable).
Circuit Voltage Above Threshold
All functions handled by Door Control Panel are not working as expected.
1. Harness issue.
2. Passenger Door Module internal HW issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the Door Control Panel.
– Inspect the harness or connectors.
Door Control Panel 12V power supply circuit
————————————————————————————————————————————————————————————
B100111
Output pin short circuit to GND.
Circuit Short To Ground
Turns off Window Antipinch 12V power supply.
Power window function is not working as expected.
1. Harness issue. 2.Antipinch internal short circuit.
Diagnostic Service 14. No additional action is needed.
– Inspect the Window Antipinch Module.
– Inspect the harness or connectors.
Antipinch module 12V power supply circuit
————————————————————————————————————————————————————————————
B100112
Output pin short circuit to BAT+.
Circuit Short To Battery
Turns off Window Antipinch 12V power supply.
Power window function is not working as expected.
1. Harness issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the Window Antipinch Module.
– Inspect the harness or connectors.
Antipinch module 12V power supply circuit
————————————————————————————————————————————————————————————
B100113
Open circuit conditions detected on output pin.
Circuit Open
Power window function is not working as expected.
1. Harness issue.
2. Antipinch internal failure.
Diagnostic Service 14. No additional action is needed.
– Inspect the Window Antipinch Module.
– Inspect the harness or connectors.
Antipinch module 12V power supply circuit
————————————————————————————————————————————————————————————
B100116
Feedback voltage measured on the output is lower than 11,4V threshold (configurable).
Circuit Voltage Below Threshold
Power window function is not working as expected.
1. Harness issue.
2. PDM internal HW issue.
3. Antipinch internal HW failure.
Diagnostic Service 14. No additional action is needed.
– Inspect the Window Antipinch Module.
– Inspect the harness or connectors.
Antipinch module 12V power supply circuit
————————————————————————————————————————————————————————————
B100117
Feedback voltage measured on the output is higher 14V threshold
(configurable).
Circuit Voltage Above Threshold
Power window function is not working as expected.
1. Harness issue.
2. PDM internal HW issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the Window Antipinch Module.
– Inspect the harness or connectors.
Antipinch module 12V power supply circuit
————————————————————————————————————————————————————————————
B100811
Output pin short circuit to GND.
Circuit Short To Ground
Mirror function is not working as expected.
1. Harness issue.
2. Actuator motor blown.
Diagnostic Service 14. No additional action is needed.
– Inspect the mirrors.
– Inspect the harness and connectors.
Mirrors adjustment actuators common circuit
————————————————————————————————————————————————————————————
B100812
Output pin short circuit to BAT+.
Circuit Short To Battery
Mirror function is not working as expected.
1. Harness issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the mirrors.
– Inspect the harness and connectors.
Mirrors adjustment actuators common circuit
————————————————————————————————————————————————————————————
B100911
Output pin short circuit to GND.
Circuit Short To Ground
Mirror function is not working as expected.
1. Harness issue.
2. Actuator motor blown.
Diagnostic Service 14. No additional action is needed.
– Inspect the mirrors.
– Inspect the harness and connectors.
Main Mirror X adjustment actuator circuit
————————————————————————————————————————————————————————————
B100912
Output pin short circuit to BAT+.
Circuit Short To Battery
Mirror function is not working as expected.
1. Harness issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the mirrors.
– Inspect the harness and connectors.
Main Mirror X adjustment actuator circuit
————————————————————————————————————————————————————————————
B100913
Open circuit conditions detected on output pin.
Circuit Open
Mirror function is not working as expected.
1. Harness issue.
2. Actuator motor blown.
Diagnostic Service 14. No additional action is needed.
– Inspect the mirrors.
– Inspect the harness and connectors.
Main Mirror X adjustment actuator circuit
————————————————————————————————————————————————————————————
B100919
Feedback load current measured on the output is higher than defined threshold.
Threshold depends on multiple criteria (voltage, temperature and motor type).
Circuit Current Above Threshold
Mirror function is not working as expected.
ECU switches off main and wide mirror motors outputs for 60 seconds.
1. Mirror actuator issue;
2. Mirror mechanical issue (anormal resistance).
Diagnostic Service 14. No additional action is needed.
– Inspect the mirrors.
– Inspect the harness and connectors.
Main Mirror X adjustment actuator circuit
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
————————————————————————————————————————————————————————————
B100A11
Output pin short circuit to GND.
Circuit Short To Ground
Mirror function is not working as expected.
1. Harness issue.
2. Actuator motor blown.
Diagnostic Service 14. No additional action is needed.
– Inspect the mirrors.
– Inspect the harness and connectors.
Main Mirror Y adjustment actuator circuit
————————————————————————————————————————————————————————————
B100A12
Output pin short circuit to BAT+.
Circuit Short To Battery
Mirror function is not working as expected.
1. Harness issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the mirrors.
– Inspect the harness and connectors.
Main Mirror Y adjustment actuator circuit
————————————————————————————————————————————————————————————
B100A13
Open circuit conditions detected on output pin.
Circuit Open
Mirror function is not working as expected.
1. Harness issue.
2. Actuator motor blown.
Diagnostic Service 14. No additional action is needed.
– Inspect the mirrors.
– Inspect the harness and connectors.
Main Mirror Y adjustment actuator circuit
————————————————————————————————————————————————————————————
B100A19
Feedback load current measured on the output is higher than defined threshold.
Threshold depends on multiple criteria (voltage, temperature and motor type).
Circuit Current Above Threshold
Mirror function is not working as expected.
ECU switches off main and wide mirror motors outputs for 60 seconds.
1. Mirror actuator issue;
2. Mirror mechanical issue (anormal resistance).
Diagnostic Service 14. No additional action is needed.
– Inspect the mirrors.
– Inspect the harness and connectors.
Main Mirror Y adjustment actuator circuit
————————————————————————————————————————————————————————————
B100B11
Output pin short circuit to GND.
Circuit Short To Ground
Mirror function is not working as expected.
1. Harness issue.
2. Actuator motor blown.
Diagnostic Service 14. No additional action is needed.
– Inspect the mirrors.
– Inspect the harness and connectors.
Wide Mirror X adjustment actuator circuit
————————————————————————————————————————————————————————————
B100B12
Output pin short circuit to BAT+.
Circuit Short To Battery
Mirror function is not working as expected.
1. Harness issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the mirrors.
– Inspect the harness and connectors.
Wide Mirror X adjustment actuator circuit
————————————————————————————————————————————————————————————
B100B13
Open circuit conditions detected on output pin
Circuit Open
Mirror function is not working as expected.
1. Harness issue.
2. Actuator motor blown.
Diagnostic Service 14. No additional action is needed.
– Inspect the mirrors.
– Inspect the harness and connectors.
Wide Mirror X adjustment actuator circuit
————————————————————————————————————————————————————————————
B100B19
Feedback load current measured on the output is higher than defined threshold.
Threshold depends on multiple criteria (voltage, temperature and motor type).
Circuit Current Above Threshold
Mirror function is not working as expected.
ECU switches off main and wide mirror motors outputs for 60 seconds.
1. Mirror actuator issue;
2. Mirror mechanical issue (anormal resistance).
Diagnostic Service 14. No additional action is needed.
– Inspect the mirrors.
– Inspect the harness and connectors.
Wide Mirror X adjustment actuator circuit
————————————————————————————————————————————————————————————
B100C11
Output pin short circuit to GND.
Circuit Short To Ground
Mirror function is not working as expected.
1. Harness issue.
2. Actuator motor blown.
Diagnostic Service 14. No additional action is needed.
– Inspect the mirrors.
– Inspect the harness and connectors.
Wide Mirror Y adjustment actuator circuit
————————————————————————————————————————————————————————————
B100C12
Output pin short circuit to BAT+.
Circuit Short To Battery
Mirror function is not working as expected.
1. Harness issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the mirrors.
– Inspect the harness and connectors.
Wide Mirror Y adjustment actuator circuit
————————————————————————————————————————————————————————————
B100C13
Open circuit conditions detected on output pin.
Circuit Open
Mirror function is not working as expected.
1. Harness issue.
2. Actuator motor blown.
Diagnostic Service 14. No additional action is needed.
– Inspect the mirrors.
– Inspect the harness and connectors.
Wide Mirror Y adjustment actuator circuit
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
————————————————————————————————————————————————————————————
B100C19
Feedback load current measured on the output is higher than defined threshold.
Threshold depends on multiple criteria (voltage, temperature and motor type).
Circuit Current Above Threshold
Mirror function is not working as expected.
ECU switches off main and wide mirror motors outputs for 60 seconds.
1. Mirror actuator issue;
2. Mirror mechanical issue (anormal resistance).
Diagnostic Service 14. No additional action is needed.
– Inspect the mirrors.
– Inspect the harness and connectors.
Wide Mirror Y adjustment actuator circuit
————————————————————————————————————————————————————————————
B100211
Output pin short circuit to GND.
Circuit Short To Ground
Switch off output until :
1. next Vehicle Mode change from lower than Pre- Running to higher or equal to PreRunning
2. New activation request.
1. Harness issue.
2. Lamp mounting issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the lamp.
– Inspect the harness and connectors.
Door instep lamp circuit
————————————————————————————————————————————————————————————
B100212
Output pin short circuit to BAT+.
Circuit Short To Battery
Switch off output until :
1. next Vehicle Mode change from lower than Pre- Running to higher or equal to PreRunning
2. New activation request.
1. Harness issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the lamp.
– Inspect the harness and connectors.
Door instep lamp circuit
————————————————————————————————————————————————————————————
B100213
Open circuit conditions detected on output pin.
Circuit Open
Switch off output until :
1. next Vehicle Mode change from lower than Pre- Running to higher or equal to PreRunning
2. New activation request.
1. Harness issue.
2. Lamp blown.
Diagnostic Service 14. No additional action is needed.
– Inspect the lamp.
– Inspect the harness and connectors.
Door instep lamp circuit
————————————————————————————————————————————————————————————
B100311
Output pin short circuit to GND.
Circuit Short To Ground
Switch off output until :
1. next Vehicle Mode change from lower than Pre- Running to higher or equal to PreRunning
2. New activation request.
1. Harness issue.
2. Lamp mounting issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the lamp.
– Inspect the harness and connectors.
Door warning lamp circuit
————————————————————————————————————————————————————————————
B100312
Output pin short circuit to BAT+.
Circuit Short To Battery
Switch off output until :
1. next Vehicle Mode change from lower than Pre- Running to higher or equal to PreRunning
2. New activation request.
1. Harness issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the lamp.
– Inspect the harness and connectors.
Door warning lamp circuit
————————————————————————————————————————————————————————————
B100313
Open circuit conditions detected on output pin.
Circuit Open
Switch off output until :
1. next Vehicle Mode change from lower than Pre- Running to higher or equal to PreRunning
2. New activation request.
1. Harness issue.
2. Lamp blown.
Diagnostic Service 14. No additional action is needed.
– Inspect the lamp.
– Inspect the harness and connectors.
Door warning lamp circuit
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
————————————————————————————————————————————————————————————
B100611
Output pin short circuit to GND.
Circuit Short To Ground
Power window function is not working as expected.
– For window down request, window will be driven down.
– For window up request, it will not be executed.
1. Harness issue.
2. Actuator motor blown.
Diagnostic Service 14. No additional action is needed.
– Inspect the Power Window Motor.
– Inspect the harness and connectors.
Power window actuator circuit 1
————————————————————————————————————————————————————————————
B100612
Output pin short circuit to BAT+.
Circuit Short To Battery
Power window function is not working as expected.
– For window down request, it will not be executed.
– For window up request, window will driven up.
1. Harness issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the Power Window Motor.
– Inspect the harness and connectors.
Power window actuator circuit 1
————————————————————————————————————————————————————————————
B100711
Output pin short circuit to GND.
Circuit Short To Ground
Power window function is not working as expected.
– For window down request, it will not be executed.
– For window up request, window will driven up.
1. Harness issue.
2. Actuator motor blown.
Diagnostic Service 14. No additional action is needed.
– Inspect the Power Window Motor.
– Inspect the harness and connectors.
Power window actuator circuit 2
————————————————————————————————————————————————————————————
B100712
Output pin short circuit to BAT+.
Circuit Short To Battery
Power window function is not working as expected.
– For window down request, window will be driven down.
– For window up request, it will not be executed.
1. Harness issue.
Diagnostic Service 14. No additional action is needed.
– Inspect the Power Window Motor.
– Inspect the harness and connectors.
Power window actuator circuit 2
————————————————————————————————————————————————————————————
B150613
Open circuit conditions detected on output pin.
Circuit Open
Power window function is not working as expected.
– For down command, it will not be executed.
– For up command,it will not be executed.
1. Harness issue.
2. Actuator motor blown.
Diagnostic Service 14. No additional action is needed.
– Inspect the Power Window Motor.
– Inspect the Door seal ageing.
– Inspect the harness and connectors.
Power Window Motor
————————————————————————————————————————————————————————————
B150618
Feedback load current measured on the output is lower than defined threshold. Threshold is dynamic and based on multicriteria formula (voltage, temperature and motor type).
Circuit Current Below Threshold
Power window function is not working as expected.
1. Anormal window mechanical resistance,
2. Power motor issue (Thermal switch open, etc),
3. Door sealing ageing.
Diagnostic Service 14. No additional action is needed.
– Inspect the Power Window Motor.
– Inspect the Door seal ageing.
– Inspect the harness and connectors.
Power Window Motor
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
————————————————————————————————————————————————————————————
B150619
Feedback load current measured on the output is higher than defined threshold. Threshold is dynamic and based on multicriteria formula (voltage, temperature and motor type).
Circuit Current Above Threshold
Power window function is not working as expected.
1. Anormal window mechanical resistance,
2. Power motor issue,
3. Door sealing ageing.
Diagnostic Service 14. No additional action is needed.
– Inspect the Power Window Motor.
– Inspect the Door seal ageing.
– Inspect the harness and connectors.
Power Window Motor