CIOM Volvo FH4

—————————————————————————————————————-

B100111

Input stay connected to GND more than defined time (P1DWC).

Circuit Short To Ground

Auxiliary Horn function switched off until the low voltage state exit (or button release).

Harness issue, button unexpected usage: press too long.

Diagnostic Service 14. No additional action is needed.

– Inspect the switch

– Inspect the harness and connectors

Auxiliary Horn Switch Circuit

—————————————————————————————————————-

B100112

Resident voltage level in circuit when not expected by function.

Circuit Short To Battery

– if direct 24V short circuit with fuse, fuse or button itself will blow when button is pressed;

– if short circuit with protected output, this output will be affected when button is pressed (short to ground from

output perspective);

1. Harness issue.

Diagnostic Service 14. No additional action is needed.

– Inspect the switch

– Inspect the harness and connectors

Auxiliary Horn Switch Circuit

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

—————————————————————————————————————-

B150C63

Switch stay in push state more than allowed time: depends of switch.

Circuit / Component Protection Time-Out

Axle load request deactivated and button press is not processed.

1. Button failure.

2. Driver press the button too long time.

Diagnostic Service 14. No additional action is needed.

– Inspect the switch

Axle Load Distribution Button

—————————————————————————————————————-

U114288

Communication off on LIN bus.

Bus off

ECU invalidate related LIN signals.

1. Harness issue: short circuit to GND/BAT or LIN bus is out of operational range: [8V..18V];

2. Issue on one of the LIN

nodes;

Diagnostic Service 14. No additional action is needed.

Inspect the harness or connectors

LIN1 Communication Net

—————————————————————————————————————-

U114388

Communication off on LIN bus.

Bus off

ECU invalidate related signals.

1. Harness issue: short circuit to GND/BAT or LIN bus is out of operational range: [8V..18V];

2. Issue on one of the LIN

nodes;

Diagnostic Service 14. No additional action is needed.

Inspect the harness or connectors

LIN2 communication Net

—————————————————————————————————————-

U114488

Communication off on LIN bus.

Bus off

ECU invalidate related signals.

1. Harness issue: short circuit to GND/BAT or LIN bus is out of operational range: [8V..18V];

2. Issue on one of the LIN

nodes;

Diagnostic Service 14. No additional action is needed.

Inspect the harness or connectors

LIN3 Communication Net

—————————————————————————————————————-

U114588

Communication off on LIN bus.

Bus off

ECU invalidate related signals.

1. Harness issue: short circuit to GND/BAT or LIN bus is out of operational range: [8V..18V];

2. Issue on one of the LIN

nodes;

Diagnostic Service 14. No additional action is needed.

Inspect the harness or connectors

LIN4 Communication Net

—————————————————————————————————————-

U114688

Communication off on LIN bus.

Bus off

ECU invalidate related signals.

1. Harness issue: short circuit to GND/BAT or LIN bus is out of operational range: [8V..18V];

2. Issue on one of the LIN

nodes;

Diagnostic Service 14. No additional action is needed.

Inspect the harness or connectors

LIN5 Communication Net

—————————————————————————————————————-

U114E86

Invalid frame

received from LIN slave.

Signal Invalid

ECU invalidate related signals.

“LIN slave issue.

Invalid parameters setting.”

Diagnostic Service 14. No additional action is needed.

Inspect the Flexible Switch Panel

Flexible Switch Panel Link

—————————————————————————————————————-

U114E87

LIN slave not responding.

Missing Message

ECU invalidate related signals.

1. LIN slave issue.

2. Harness issue.

3. Invalid parameters setting.

Note: Set together with B100313 (CIOM 12V power

supply circuit – Circuit Open) indicates the global 12V power supply outputs issue.

Diagnostic Service 14. No additional action is needed.

– Inspect the Flexible Switch Panel

– Inspect the harness

Flexible Switch Panel Link

—————————————————————————————————————-

U114786

Invalid frame

received from LIN slave.

Signal Invalid

ECU invalidate related signals.

“LIN slave issue.

Invalid parameters setting.”

Diagnostic Service 14. No additional action is needed.

– Inspect the Cruise Control Free Wheel

Cruise Control Free Wheel Module Link

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

—————————————————————————————————————-

U114787

LIN slave not responding.

Missing Message

ECU invalidate related signals.

1. LIN slave issue.

2. Harness issue.

3. Invalid parameters setting.

Note: Set together with B100313 (CIOM 12V power

supply circuit – Circuit Open) indicates the global 12V power supply outputs issue.

Diagnostic Service 14. No additional action is needed.

– Inspect the Cruise Control Free Wheel

– Inspect the harness

Cruise Control Free Wheel Module Link

—————————————————————————————————————-

U114886

Invalid frame received from LIN

slave.

Signal Invalid

ECU invalidate related signals.

“LIN slave issue.

Invalid parameters setting.”

Diagnostic Service 14. No additional action is needed.

– Inspect the Exterior Light Control Panel

Exterior Light Control Panel Link

—————————————————————————————————————-

U114887

LIN slave not responding.

Missing Message

ECU invalidate related signals.

1. LIN slave issue.

2. Harness issue.

3. Invalid parameters setting.

Note: Set together with B100313 (CIOM 12V power

supply circuit – Circuit Open) indicates the global 12V power supply outputs issue.

Diagnostic Service 14. No additional action is needed.

– Inspect the Exterior Light Control Panel

– Inspect the harness

Exterior Light Control Panel Link

—————————————————————————————————————-

U114986

Invalid frame received from LIN slave.

Signal Invalid

ECU invalidate related signals.

“LIN slave issue.

Invalid parameters setting.”

Diagnostic Service 14. No additional action is needed.

– Inspect the Interior Light Control Panel

Interior Light Control Panel Link

—————————————————————————————————————-

U114987

LIN slave not responding.

Missing Message

ECU invalidate related signals.

1. LIN slave issue.

2. Harness issue.

3. Invalid parameters setting.

Note: Set together with B100313 (CIOM 12V power

supply circuit – Circuit Open) indicates the global 12V power supply outputs issue.

Diagnostic Service 14. No additional action is needed.

– Inspect the Interior Light Control Panel

– Inspect the harness

Interior Light Control Panel Link

—————————————————————————————————————-

U114A86

Invalid frame

received from LIN slave.

Signal Invalid

ECU invalidate related signals.

“LIN slave issue.

Invalid parameters setting.”

Diagnostic Service 14. No additional action is needed.

– Inspect the Remote Control ECS Module

Remote Control ECS Module Link

—————————————————————————————————————-

U114A87

LIN slave not responding.

Missing Message

ECU invalidate related signals.

1. LIN slave issue.

2. Harness issue.

3. Invalid parameters setting.

Note: Set together with B100313 (CIOM 12V power

supply circuit – Circuit Open) indicates the global 12V power supply outputs issue.

Diagnostic Service 14. No additional action is needed.

– Inspect the Remote Control ECS Module

– Inspect the harness

Remote Control ECS Module Link

—————————————————————————————————————-

U114B86

Invalid frame

received from LIN slave.

Signal Invalid

ECU invalidate related signals.

“LIN slave issue.

Invalid parameters setting.”

Diagnostic Service 14. No additional action is needed.

– Inspect the High Living Electronics Control Module

High Living Electronics Control Module Link

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

—————————————————————————————————————-

U114B87

LIN slave not responding.

Missing Message

ECU invalidate related signals.

1. LIN slave issue.

2. Harness issue.

3. Invalid parameters setting.

Note: Set together with B100313 (CIOM 12V power

supply circuit – Circuit Open) indicates the global 12V power supply outputs issue.

Diagnostic Service 14. No additional action is needed.

– Inspect the High Living Electronics Control Module

– Inspect the harness

High Living Electronics Control Module Link

—————————————————————————————————————-

U114C86

Invalid frame received from LIN

slave.

Signal Invalid

ECU invalidate related signals.

“LIN slave issue.

Invalid parameters setting.”

Diagnostic Service 14. No additional action is needed.

– Inspect the Living Enviroment Control Module Low

Living Enviroment Control Module Low Link

—————————————————————————————————————-

U114C87

LIN slave not responding.

Missing Message

ECU invalidate related signals.

1. LIN slave issue.

2. Harness issue.

3. Invalid parameters setting.

Note: Set together with B100313 (CIOM 12V power

supply circuit – Circuit Open) indicates the global 12V power supply outputs issue.

Diagnostic Service 14. No additional action is needed.

– Inspect the Living Enviroment Control Module Low

– Inspect the harness

Living Enviroment Control Module Low Link

—————————————————————————————————————-

U114D86

Invalid frame received from LIN slave.

Signal Invalid

ECU invalidate related signals.

“LIN slave issue.

Invalid parameters setting.”

Diagnostic Service 14. No additional action is needed.

– Inspect the Diff Lock Free Wheel Module

Diff Lock Free Wheel Module Link

—————————————————————————————————————-

U114D87

LIN slave not responding.

Missing Message

ECU invalidate related signals.

1. LIN slave issue.

2. Harness issue.

3. Invalid parameters setting.

Note: Set together with B100313 (CIOM 12V power

supply circuit – Circuit Open) indicates the global 12V power supply outputs issue.

Diagnostic Service 14. No additional action is needed.

– Inspect the Diff Lock Free Wheel Module

– Inspect the harness

Diff Lock Free Wheel Module Link

—————————————————————————————————————-

B150216

LIN slave measures power supply voltage lower than 7.5V (FCI reception).

Circuit Voltage Below Threshold

LIN slave:

– Standby state.

– Untrustable signals:None.

1. Harness issue;

2. CIOM 12V output failure;

3. Faulty LIN slave hardware that misdetect the supply level;

Diagnostic Service 14. No additional action is needed.

– Inspect the Cruise Control Free Wheel Panel

– Inspect the harness

Cruise Control Free Wheel Panel

—————————————————————————————————————-

B150217

LIN slave measures power supply voltage higher than 18.5V (FCI

reception).

Circuit Voltage Above Threshold

LIN slave:

– Standby state.

– Untrustable signals:None.

1. Harness issue;

2. CIOM 12V output failure;

3. Faulty LIN slave hardware that misdetect the supply level;

Diagnostic Service 14. No additional action is needed.

– Inspect the Cruise Control Free Wheel Panel

– Inspect the harness

Cruise Control Free Wheel Panel

—————————————————————————————————————-

B150244

LIN slave RAM check fail (FCI reception).

Data Memory Failure

LIN Master invalidates the LIN input signals (set them to Error).

1. LIN slave SW issue.

2. LIN slave RAM physical corruption.

Diagnostic Service 14. No additional action is needed.

– Replace the Cruise Control Free Wheel Panel

Cruise Control Free Wheel Panel

—————————————————————————————————————-

B150245

LIN slave ROM check fail (FCI reception).

Program Memory Failure

LIN Master invalidates the LIN input signals (set them to Error).

1. LIN slave ROM physical corruption.

Diagnostic Service 14. No additional action is needed.

– Replace the Cruise Control Free Wheel Panel

Cruise Control Free Wheel Panel

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

—————————————————————————————————————-

B150246

LIN slave flash corruption detected during writing of calibration data (FCI reception).

Calibration / Parameter Memory Failure

LIN Master invalidates the LIN input signals (set them to Error).

1. LIN slave flash memory corruption.

Diagnostic Service 14. No additional action is needed.

– Replace the Cruise Control Free Wheel Panel

Cruise Control Free Wheel Panel

—————————————————————————————————————-

B150294

LIN slave unexpected SW operation executed; LIN slave watchdog reset performed; LIN slave overrun situation detected;

Unexpected Operation

LIN Master invalidates the LIN input signals (set them to Error).

1. LIN slave SW issue;

2. LIN slave MCU not correct;

Diagnostic Service 14. No additional action is needed.

– Replace the Cruise Control Free Wheel Panel

Cruise Control Free Wheel Panel

—————————————————————————————————————-

B150316

LIN slave measures power supply voltage lower than 7.5V (FCI reception).

Circuit Voltage Below Threshold

LIN slave:

– Standby state.

– Untrustable signals:None.

1. Harness issue;

2. CIOM 12V output failure;

3. Faulty LIN slave hardware that misdetect the supply level;

Diagnostic Service 14. No additional action is needed.

– Inspect the Diff Lock Free Wheel Panel

– Inspect the harness

Diff Lock Free Wheel Panel

—————————————————————————————————————-

B150317

LIN slave measures power supply voltage higher than 18.5V (FCI

reception).

Circuit Voltage Above Threshold

LIN slave:

– Standby state.

– Untrustable signals:None.

1. Harness issue;

2. CIOM 12V output failure;

3. Faulty LIN slave hardware that misdetect the supply level;

Diagnostic Service 14. No additional action is needed.

– Inspect the Diff Lock Free Wheel Panel

– Inspect the harness

Diff Lock Free Wheel Panel

—————————————————————————————————————-

B150344

LIN slave RAM check fail (FCI reception).

Data Memory Failure

LIN Master invalidates the LIN input signals (set them

to Error).

1. LIN slave SW issue.

2. LIN slave RAM physical corruption.

Diagnostic Service 14. No additional action is needed.

– Replace the Diff Lock Free Wheel Panel

Diff Lock Free Wheel Panel

—————————————————————————————————————-

B150345

LIN slave ROM check fail (FCI reception).

Program Memory Failure

LIN Master invalidates the LIN input signals (set them

to Error).

1. LIN slave ROM physical corruption.

Diagnostic Service 14. No additional action is needed.

– Replace the Diff Lock Free Wheel Panel

Diff Lock Free Wheel Panel

—————————————————————————————————————-

B150346

LIN slave flash corruption detected during writing of calibration data (FCI reception).

Calibration / Parameter Memory Failure

LIN Master invalidates the LIN input signals (set them to Error).

1. LIN slave flash memory corruption.

Diagnostic Service 14. No additional action is needed.

– Replace the Diff Lock Free Wheel Panel

Diff Lock Free Wheel Panel

—————————————————————————————————————-

B150394

LIN slave unexpected SW operation executed; LIN slave watchdog reset performed; LIN slave overrun situation detected;

Unexpected Operation

LIN Master invalidates the LIN input signals (set them to Error).

1. LIN slave SW issue;

2. LIN slave MCU not correct;

Diagnostic Service 14. No additional action is needed.

– Replace the Diff Lock Free Wheel Panel

Diff Lock Free Wheel Panel

—————————————————————————————————————-

B150516

LIN slave measures power supply voltage lower than 7.5V (FCI reception).

Circuit Voltage Below Threshold

LIN slave:

– Standby state.

– Untrustable signals:None.

1. Harness issue;

2. CIOM 12V output failure;

3. Faulty LIN slave hardware that misdetect the supply level;

Diagnostic Service 14. No additional action is needed.

– Inspect the Interior Light Control Panel

– Inspect the harness

Interior Light Control Panel

—————————————————————————————————————-

B150517

LIN slave measures power supply voltage higher than 18.5V (FCI

reception).

Circuit Voltage Above Threshold

LIN slave:

– Standby state.

– Untrustable signals:None.

1. Harness issue;

2. CIOM 12V output failure;

3. Faulty LIN slave hardware that misdetect the supply level;

Diagnostic Service 14. No additional action is needed.

– Inspect the Interior Light Control Panel

– Inspect the harness

Interior Light Control Panel

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

—————————————————————————————————————-

B150544

LIN slave RAM check fail (FCI reception).

Data Memory Failure

LIN Master invalidates the LIN input signals (set them

to Error).

1. LIN slave SW issue.

2. LIN slave RAM physical corruption.

Diagnostic Service 14. No additional action is needed.

– Replace the Interior Light Control Panel

Interior Light Control Panel

—————————————————————————————————————-

B150545

LIN slave ROM check fail (FCI reception).

Program Memory Failure

LIN Master invalidates the LIN input signals (set them

to Error).

1. LIN slave ROM physical corruption.

Diagnostic Service 14. No additional action is needed.

– Replace the Interior Light Control Panel

Interior Light Control Panel

—————————————————————————————————————-

B150546

LIN slave flash corruption detected during writing of calibration data (FCI reception).

Calibration / Parameter Memory Failure

LIN Master invalidates the LIN input signals (set them to Error).

1. LIN slave flash memory corruption.

Diagnostic Service 14. No additional action is needed.

– Replace the Interior Light Control Panel

Interior Light Control Panel

—————————————————————————————————————-

B150549

Push button scan is not configured correctly (FCI reception).

Internal Electronic Failure

LIN slave invalidates corresponding signals.

1. LIN slave EOL configuration not correct

Diagnostic Service 14. No additional action is needed.

– Replace the Interior Light Control Panel

Interior Light Control Panel

—————————————————————————————————————-

B150594

LIN slave unexpected SW operation executed; LIN slave watchdog reset performed; LIN slave overrun situation detected;

Unexpected Operation

LIN Master invalidates the LIN input signals (set them to Error).

1. LIN slave SW issue;

2. LIN slave MCU not correct;

Diagnostic Service 14. No additional action is needed.

– Replace the Interior Light Control Panel

Interior Light Control Panel

—————————————————————————————————————-

B150916

Supply voltage measured by LIN slave < 7V±0.5.

Circuit Voltage Below Threshold

LIN slave behaviour:

– All illumination will be turned off after 5s.

– All switch status will be set to “Not pressed”.

– Untrustable signals:None

1. Harness issue;

2. CIOM 12V output failure;

3. Faulty LIN slave hardware that misdetect the supply level;

Diagnostic Service 14. No additional action is needed.

– Inspect the Flexible Switch Panel

– Inspect the harness

Flexible Switch Panel

—————————————————————————————————————-

B150917

Supply voltage measured by LIN slave > 18V±0.5.

Circuit Voltage Above Threshold

LIN slave behaviour:

– All illumination will be turned off immediately.

– All switch status will be set to “Not pressed”.

– Untrustable signals:None.

1. Harness issue;

2. CIOM 12V output failure;

3. Faulty LIN slave hardware that misdetect the supply level;

Diagnostic Service 14. No additional action is needed.

– Inspect the Flexible Switch Panel

– Inspect the harness

Flexible Switch Panel

—————————————————————————————————————-

B150944

LIN slave RAM check fail (FCI reception).

Data Memory Failure

LIN Master invalidates the

LIN input signals (set them to Error).

1. LIN slave SW issue.

2. LIN slave RAM physical corruption.

Diagnostic Service 14. No additional action is needed.

– Replace the Flexible Switch Panel

Flexible Switch Panel

—————————————————————————————————————-

B150979

Read switch ID error or no response from flexible switch (FCI reception).

Mechanical Linkage Failure

LIN Master invalidates the LIN input signals corresponding to position of the switch in failure(set them to Error).

1. Flexible switch removed/disconnected;

2. Flexible switch failure:

– wrong data in EEPROM

– noise on the IIC-Bus

– SCL has a short circuit to GND or VCC

– SDA has a short circuit to GND or VCC

– CS has a short circuit to GND or VCC

Diagnostic Service 14. No additional action is needed.

– Inspect connection between Switches and Panels

Flexible Switch Panel

—————————————————————————————————————-

B150616

LIN slave measures power supply voltage lower than 7.5V (FCI reception).

Circuit Voltage Below Threshold

LIN slave:

– Standby state.

– Untrustable signals:None.

1. Harness issue;

2. CIOM 12V output failure;

3. Faulty LIN slave hardware that misdetect the supply level;

Diagnostic Service 14. No additional action is needed.

– Inspect the Exterior Light Control Panel

– Inspect the harness

Exterior Light Control Panel

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

—————————————————————————————————————-

B150617

LIN slave measures power supply voltage higher than 18.5V (FCI

reception).

Circuit Voltage Above Threshold

LIN slave:

– Standby state.

– Untrustable signals:None.

1. Harness issue;

2. CIOM 12V output failure;

3. Faulty LIN slave hardware that misdetect the supply level;

Diagnostic Service 14. No additional action is needed.

– Inspect the Exterior Light Control Panel

– Inspect the harness

Exterior Light Control Panel

—————————————————————————————————————-

B150644

LIN slave RAM check fail (FCI reception).

Data Memory Failure

LIN Master invalidates the LIN input signals (set them to Error).

1. LIN slave SW issue.

2. LIN slave RAM physical corruption.

Diagnostic Service 14. No additional action is needed.

– Replace the Exterior Light Control Panel

Exterior Light Control Panel

—————————————————————————————————————-

B150645

LIN slave ROM check fail (FCI reception).

Program Memory Failure

LIN Master invalidates the LIN input signals (set them to Error).

1. LIN slave ROM physical corruption.

Diagnostic Service 14. No additional action is needed.

– Replace the Exterior Light Control Panel

Exterior Light Control Panel

—————————————————————————————————————-

B150646

LIN slave flash corruption detected during writing of calibration data (FCI reception).

Calibration / Parameter Memory Failure

LIN Master invalidates the LIN input signals (set them to Error).

1. LIN slave flash memory corruption.

Diagnostic Service 14. No additional action is needed.

– Replace the Exterior Light Control Panel

Exterior Light Control Panel

—————————————————————————————————————-

B150649

Push button scan is not configured correctly (FCI reception).

Internal Electronic Failure

LIN slave invalidates corresponding signals.

1. LIN slave EOL configuration not correct.

Diagnostic Service 14. No additional action is needed.

– Replace the Exterior Light Control Panel

Exterior Light Control Panel

—————————————————————————————————————-

B150694

LIN slave unexpected SW operation executed; LIN slave watchdog reset performed; LIN slave overrun situation detected;

Unexpected Operation

LIN Master invalidates the LIN input signals (set them to Error).

1. LIN slave SW issue;

2. LIN slave MCU not correct;

Diagnostic Service 14. No additional action is needed.

– Replace the Exterior Light Control Panel

Exterior Light Control Panel

—————————————————————————————————————-

B150816

LIN slave measures power supply voltage lower than 8.0V (FCI reception).

Circuit Voltage Below Threshold

LIN slave: the fault is reported when the system has going back from high voltage state to normal. This means that when FCI is reported the unit is function correctly. In the low voltage state the LEDs are deactivated and the LIN communication is shut down.

1. Harness issue;

2. CIOM 12V output failure;

3. Faulty LIN slave hardware that misdetect the supply level;

Diagnostic Service 14. No additional action is needed.

– Inspect the Living Environment Control Module Low

– Inspect the harness

Living Environment Control Module Low

—————————————————————————————————————-

B150817

LIN slave measures power supply voltage higher than 18.0V (FCI

reception).

Circuit Voltage Above Threshold

LIN slave: the fault is reported when the system has going back from high voltage state to normal. This means that when FCI is reported the unit is function correctly. In the high  voltage state the LEDs are deactivated and the LIN communication is shut down.

1. Harness issue;

2. CIOM 12V output failure;

3. Faulty LIN slave hardware that misdetect the supply level;

Diagnostic Service 14. No additional action is needed.

– Inspect the Living Environment Control Module Low

– Inspect the harness

Living Environment Control Module Low

—————————————————————————————————————-

B150846

LIN slave flash corruption detected during writing of calibration data (FCI reception).

Calibration / Parameter Memory Failure

LIN Master invalidates the LIN input signals (set them to Error).

1. LIN slave flash memory corruption.

Diagnostic Service 14. No additional action is needed.

– Replace the Living Environment Control Module Low

Living Environment Control Module Low

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

—————————————————————————————————————-

B150894

LIN slave unexpected SW operation executed; LIN slave watchdog reset performed; LIN slave overrun situation detected;

Unexpected Operation

LIN Master invalidates the LIN input signals (set them to Error).

1. LIN slave SW issue;

2. LIN slave MCU not correct;

Diagnostic Service 14. No additional action is needed.

– Replace the Living Environment Control Module Low

Living Environment Control Module Low

—————————————————————————————————————-

B150716

LIN slave measures power supply voltage lower than 7.5V (FCI reception).

Circuit Voltage Below Threshold

LIN slave: turn of LIN communication, backlights and display.

1. Harness issue;

2. CIOM 12V output failure;

3. Faulty LIN slave hardware that misdetect the supply level;

Diagnostic Service 14. No additional action is needed.

– Inspect the Living Environment Control Module High

– Inspect the harness

Living Environment Control Module High

—————————————————————————————————————-

B150717

LIN slave measures power supply voltage higher than 19.0V (FCI

reception).

Circuit Voltage Above Threshold

LIN slave: turn of LIN communication, backlights and display.

1. Harness issue;

2. CIOM 12V output failure;

3. Faulty LIN slave hardware that misdetect the supply level;

Diagnostic Service 14. No additional action is needed.

– Inspect the Living Environment Control Module High

– Inspect the harness

Living Environment Control Module High

—————————————————————————————————————-

B150744

LIN slave RAM check fail (FCI reception).

Data Memory Failure

LIN Master invalidates the LIN input signals (set them to Error).

1. LIN slave SW issue.

2. LIN slave RAM physical corruption.

Diagnostic Service 14. No additional action is needed.

Replace the Living Environment Control Module High

Living Environment Control Module High

—————————————————————————————————————-

B150745

LIN slave ROM check fail (FCI reception).

Program Memory Failure

LIN Master invalidates the LIN input signals (set them to Error).

1. LIN slave ROM physical corruption.

Diagnostic Service 14. No additional action is needed.

Replace the Living Environment Control Module High

Living Environment Control Module High

—————————————————————————————————————-

B150746

LIN slave flash corruption detected during writing of calibration data (FCI reception).

Calibration / Parameter Memory Failure

LIN Master invalidates the LIN input signals (set them to Error).

1. LIN slave flash memory corruption.

Diagnostic Service 14. No additional action is needed.

Replace the Living Environment Control Module High

Living Environment Control Module High

—————————————————————————————————————-

B150749

– Button stuck

– Failure to communicate (I2C) with LCD display.

– Fail to read button statuses (SPI bus error)

– LIN communication error

Internal Electronic Failure

LIN slave: invalidates corresponding signals.

– LCD display failure;

– Button interface (internal) failure;

– Button stuck;

– LIN communication issue;

Diagnostic Service 14. No additional action is needed.

Replace the Living Environment Control Module High

Living Environment Control Module High

—————————————————————————————————————-

B150794

LIN slave unexpected SW operation executed; LIN slave watchdog reset performed; LIN slave overrun situation detected;

Unexpected Operation

LIN Master invalidates the LIN input signals (set them to Error).

1. LIN slave SW issue;

2. LIN slave MCU not correct;

Diagnostic Service 14. No additional action is needed.

Replace the Living Environment Control Module High

Living Environment Control Module High

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

—————————————————————————————————————-

B150416

LIN slave measures power supply voltage lower than 8.0V (FCI reception).

Circuit Voltage Below Threshold

LIN slave: the fault is reported when the system has going back from high voltage state to normal. This means that when FCI is reported the unit is function correctly. In the low voltage state the LEDs are deactivated and the LIN communication is shut down.

1. Harness issue;

2. CIOM 12V output failure;

3. Faulty LIN slave hardware that misdetect the supply level;

Diagnostic Service 14. No additional action is needed.

– Inspect the Wired Control ECS Panel

– Inspect the harness

Wired Control ECS Panel

—————————————————————————————————————-

B150417

LIN slave measures power supply voltage higher than 18.0V (FCI

reception).

Circuit Voltage Above Threshold

LIN slave: the fault is reported when the system has going back from high voltage state to normal. This means that when FCI is reported the unit is function correctly. In the high  voltage state the LEDs are deactivated and the LIN communication is shut down.

1. Harness issue;

2. CIOM 12V output failure;

3. Faulty LIN slave hardware that misdetect the supply level;

Diagnostic Service 14. No additional action is needed.

– Inspect the Wired Control ECS Panel

– Inspect the harness

Wired Control ECS Panel

—————————————————————————————————————-

B150446

LIN slave flash corruption detected during writing of calibration data (FCI reception).

Calibration / Parameter Memory Failure

LIN Master invalidates the LIN input signals (set them to Error).

1. LIN slave flash memory corruption.

Diagnostic Service 14. No additional action is needed.

– Replace the Wired Control ECS Panel

Wired Control ECS Panel

—————————————————————————————————————-

B150494

LIN slave unexpected SW operation executed; LIN slave watchdog reset performed; LIN slave overrun situation detected;

Unexpected Operation

LIN Master invalidates the LIN input signals (set them to Error).

1. LIN slave SW issue;

2. LIN slave MCU not correct;

Diagnostic Service 14. No additional action is needed.

– Replace the Wired Control ECS Panel

Wired Control ECS Panel

—————————————————————————————————————-

B100311

Output short-circuit to GND.

Circuit Short To Ground

Switch off 12V power. Periodically check if the short circuit has been solved (5s period).

Functions activation not possible through LIN components (ILCP, ELCP CCFW, DLFW, RCECS, LECM).

“1. Harness issue;

2. LIN slave internal short circuit”

Diagnostic Service 14. No additional action is needed.

– Inspect the harness

– Inspect LIN modules

ECU 12V power supply circuit

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

—————————————————————————————————————-

B100312

Output short-circuit to BAT+.

Circuit Short To Battery

Switch off 12V power. Periodically check if the short circuit has been solved (5s period).

Functions activation not possible through LIN components (ILCP, ELCP CCFW, DLFW, RCECS, LECM).

One or more functions of ECU do not perform as expected.

1. Harness issue.

Diagnostic Service 14. No additional action is needed.

– Inspect the harness

– Inspect LIN modules

ECU 12V power supply circuit

—————————————————————————————————————-

B100313

Open circuit conditions detected on all 4 output pins. Threshold for open circuit detection:

<1mA external current at output voltages between 10V and 14V.

Circuit Open

One or more functions of ECU do not perform as expected.

Functions activation not possible through LIN components (ILCP, ELCP CCFW, DLFW, FSP, RCECS, LECM).

1. Harness issue, most probably close to CIOM connectors.

Diagnostic Service 14. No additional action is needed.

– Inspect the harness

ECU 12V power supply circuit

—————————————————————————————————————-

B100316

Feedback voltage measured on the output is lower than 11,4V threshold (configurable).

Circuit Voltage Below Threshold

One or more functions of ECU may not work as expected.

“1. Harness issue;

2. CIOM internal HW failure;

3. LIN slave internal HW failure.”

Diagnostic Service 14. No additional action is needed.

– Inspect the harness

– Inspect LIN modules

ECU 12V power supply circuit

—————————————————————————————————————-

B100317

Feedback voltage measured on the output is higher 14V threshold

(configurable).

Circuit Voltage Above Threshold

One or more functions of ECU may not work as expected.

“1. Harness issue;

2. CIOM internal HW failure;”

Diagnostic Service 14. No additional action is needed.

– Inspect the harness

ECU 12V power supply circuit

—————————————————————————————————————-

B100211

Input stay connected to GND more than defined time (P1DWB).

Circuit Short To Ground

City Horn function switched off until the low voltage state exit (or button release).

Harness issue, button unexpected usage: press too long.

Diagnostic Service 14. No additional action is needed.

– Inspect the City Horn Switch

– Inspect the harness

City Horn Switch

—————————————————————————————————————-

B100212

Resident voltage level in circuit when not expected by function.

Circuit Short To Battery

– if direct 24V short circuit with fuse, fuse or button itself will blow when button is pressed;

– if short circuit with protected output, this output will be affected when button is pressed (short to ground from

output perspective);

1. Harness issue.

Diagnostic Service 14. No additional action is needed.

– Inspect the City Horn Switch

– Inspect the harness

City Horn Switch

—————————————————————————————————————-

U000188

CAN failure detected on BB2;

Bus off

Signals invalidated by com layer accordingly to com database deadline settings. Functions processed accordingly to fallback modes.

1. Harness issue:

– Short circuit between CAN High & CAN low;

– Short circuit between CAN High & GND;

– Short circuit between CAN Low & BAT;

2. Issue on one of the CAN nodes connected to BB2.

Diagnostic Service 14. No additional action is needed.

– Inspect the harness

CAN Communication Backbone 2 Net

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

—————————————————————————————————————-

U001088

CAN failure detected BB1.

Bus off

Signals invalidated by com layer accordingly to com database deadline settings. Functions processed accordingly to fallback modes.

1. Harness issue:

– Short circuit between CAN High & CAN low;

– Short circuit between CAN High & GND;

– Short circuit between CAN Low & BAT;

2. Issue on one of the CAN nodes connected to BB1.

Diagnostic Service 14. No additional action is needed.

– Inspect the harness

CAN Communication Backbone 1 Net

—————————————————————————————————————-

U003788

CAN failure detected Cab subnet.

Bus off

Signals invalidated by com layer accordingly to com database deadline settings. Functions processed accordingly to fallback modes.

1. Harness issue:

– Short circuit between CAN High & CAN low;

– Short circuit between CAN High & GND;

– Short circuit between CAN Low & BAT;

2. Issue on one of the CAN nodes connected to Cab

subnet.

Diagnostic Service 14. No additional action is needed.

– Inspect the harness

CAN Communication Cab Net

—————————————————————————————————————-

U005588

CAN failure detected on Security Subnet.

Bus off

Signals invalidated by com layer accordingly to com database deadline settings. Functions processed accordingly to fallback modes.

1. Harness issue:

– Short circuit between CAN High & CAN low;

– Short circuit between CAN High & GND;

– Short circuit between CAN Low & BAT;

2. Issue on one of the CAN nodes connected to

Security subnet.

Diagnostic Service 14. No additional action is needed.

– Inspect the harness

CAN Communication Security Net

—————————————————————————————————————-

U200388

CAN failure detected on FMS subnet.

Bus off

Signals invalidated by com layer accordingly to com database deadline settings. Functions processed accordingly to fallback modes.

1. Harness issue:

– Short circuit between CAN High & CAN low;

– Short circuit between CAN High & GND;

– Short circuit between CAN Low & BAT;

2. Issue on one of the CAN nodes connected to FMS

subnet.

Diagnostic Service 14. No additional action is needed.

– Inspect the harness

CAN Communication FMS Net

—————————————————————————————————————-

U300005

Not supported SW configuration: invalid parameters configuration settings.

System Programming Failures

General reduced functionality of the ECU. One or more functions of ECU do not perform as expected, but return automatically to normal operation after failure is removed (mainly the function concerned by failure will be switched off,

e.g. not available signals

sent on output).

1. SW release issue;

2. Not supported truck configuration build:

– Invalid ECS functions HMI settings configured;

– Invalid DiffLock function HMI settings configured; SW or HW complex system issue, to be rised to back- office.

Diagnostic Service 14. No additional action is needed.

Contact back office

Electronic control unit

—————————————————————————————————————-

U300041

Faulty MSW or/and DST downloaded.

General Checksum Failure

MSW invalidationed: DTC reported by PBL.

1. Invalid SW downloaded;

2. Invalid HW used;

SW or HW complex system issue, to be rised to back- office;

Diagnostic Service 14. No additional action is needed.

Replace Cab I/O Module

Electronic control unit

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

—————————————————————————————————————-

U300044

RAM corruption detected.

Data Memory Failure

ECU reset.

1. Invalid SW processing;

2. RAM corruption (intermittent fault due to working environment);

3. RAM physical issue (continuous defect);

SW or HW complex system issue, to be rised to back- office.

Diagnostic Service 14. No additional action is needed.

Replace Cab I/O Module

Electronic control unit

—————————————————————————————————————-

U300045

MSW memory corruption.

Program Memory Failure

MSW invalidation after ECU reset.

1. SWDL invalid process (cut of power during SWDL, etc)

2. Flash memory physical defect;

3. Invalid SW operation; SW or HW complex system issue, to be rised to back- office.

Diagnostic Service 14. No additional action is needed.

Replace Cab I/O Module

Electronic control unit

—————————————————————————————————————-

U300046

Dataset memory corruption.

Calibration / Parameter Memory Failure

MSW invalidation after ECU reset.

1. Incorrect DST download/change (e.g. cut of power during change).

2. Invalid SW operation (mainly in case of parameters change processing);

3. Flash memory physical defect;

SW or HW complex system issue, to be rised to back- office.

Diagnostic Service 14. No additional action is needed.

Replace Cab I/O Module

Electronic control unit

—————————————————————————————————————-

U300049

Internal electronic failure detected.

Internal Electronic Failure

One or more functions of ECU are not available/not processed in expected way.

Internal electronic failure:

– µC peripheric circuit invalid state;

– LIN tranceiver circuit broken;

– CAN tranceiver circuit broken;

SW or HW complex system issue, to be rised to back- office.

Diagnostic Service 14. No additional action is needed.

Replace Cab I/O Module

Electronic control unit

—————————————————————————————————————-

U30004A

Not supported SW configuration downloaded in HW.

Incorrect Component Installed

Keyfob/FMS functions inactive in case of invalid HW(low HW version instead of high HW version).

1. Not correct component installed or not valid SW configuration downloaded:

– Remote keyless entry function activation in not supported HW version;

– FMS gateway activation in not supported HW version.

2. Not correct or not supported truck configuration build.

SW or HW complex system issue, to be rised to back- office.

Diagnostic Service 14. No additional action is needed.

Replace Cab I/O Module

Electronic control unit

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

—————————————————————————————————————-

U300054

No at least one NAD assigment procedure performed.

Missing Calibration

Flexible switch panels not processed.

No functions available through Flexible switches.

1. Invalid ECU installation procedure: Node Assignment procedure execution not performed;

2. ECU lost the RID procedure execution status (SW issue), to be rised to back-office.

Diagnostic Service 14. No additional action is needed.

Perform Node Assignment procedure

Electronic control unit

—————————————————————————————————————-

U300055

No specific SW dataset downloaded.

Not Configured

General reduced functionality of the ECU

1. No valid SW configuration downloaded (no valid LIN schedule table selected through dataset); SW or HW complex system issue, to be rised to back- office.

Diagnostic Service 14. No additional action is needed.

Replace Cab I/O Module

Electronic control unit

—————————————————————————————————————-

U300094

SW unexpected behaviour.

Unexpected Operation

ECU reset.

1. SW bug:

– unexpected SW operation executed;

– watchdog reset performed;

– overrun situation detected;

– insynchronized communication circuit state detected;

2. RAM corruption;

3. Flash corruption;

SW or HW complex system issue, to be rised to back- office.

Note: If for some reason the ECU power supply voltage (battery voltage) has exceeded 38V this DTC shall be ignored.

Diagnostic Service 14. No additional action is needed.

Replace Cab I/O Module

Electronic control unit

—————————————————————————————————————-

U300316

Power supply voltage is lower than 16V (configurable).

Circuit Voltage Below Threshold

One or more functions of ECU do not perform as expected, but return automatically to normal operation after failure is removed.

ESCL output switched low (off);

Front Lid Lock Relay Control switched low (off);

Inputs processing switched off;

Digital output diagnostics activated (ESCL, Front Lid Outputs);

1. Harness issue;

2. Power supply circuit issue;

3. ECU HW issue;

Diagnostic Service 14. No additional action is needed.

– Inspect the battery

– Inspect the harness

Battery Power

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

—————————————————————————————————————-

U300317

Power supply voltage is higher than 32V (configurable).

Circuit Voltage Above Threshold

One or more functions of ECU do not perform as expected, but return automatically to normal operation after failure is removed.

Immobilizer processing disabled;

ESCL output switched low (off);

Front Lid Lock Relay Control switched low (off);

Inputs processing switched off;

Digital output diagnostics activated (ESCL, Front Lid Outputs);

1. Harness issue;

2. Power supply circuit issue;

3. ECU HW issue;

Diagnostic Service 14. No additional action is needed.

– Inspect the battery

– Inspect the harness

Battery Power

—————————————————————————————————————-

U1FFF68

Factory Mode is active in the ECU.

Event Information

Lock control function is working in factory mode: pre-delivery mode ignored.

P1C54 parameter is set to TRUE.

Diagnostic Service 14. No additional action is needed.

Exit Factory Mode

Factory Mode Active

—————————————————————————————————————-

B151112

Resident voltage level when not expected by function.

Circuit Short To Battery

– if direct 24V short circuit with fuse, fuse or button itself will blow when button is pressed;

– if short circuit with protected output, this output will be affected when button is pressed (short to ground from

output perspective);

1. Harness issue.

Diagnostic Service 14. No additional action is needed.

– Inspect the Seat Belt Buckle Switch

– Inspect the harness

Seat Belt Buckle Switch

—————————————————————————————————————-

U114F68

Maximum number of DTC reached.

Event Information

No new DTC set until the issue solved or DTC list

cleared.

1. Unexpected environment conditions;

2. ECU failure

Diagnostic Service 14. No additional action is needed.

Clear All DTC

DTC Notification Max Limit Reached

—————————————————————————————————————-

B150A4A

Flexible switch not supported by SW: unknown switch ID, not associated with any known function.

Incorrect Component Installed

Corresponding FS ignored.

1. Flexible switch failure;

2. Not supported flexible switch installed (not valid vehicle range);

Diagnostic Service 14. No additional action is needed.

Replace faulty Flexible Switch

Unidentified switch

—————————————————————————————————————-

B150B4A

Not supported double switch configuration

present on truck.

Incorrect Component Installed

Corresponding FS ignored.

1. Double flexible switch mounting.

Diagnostic Service 14. No additional action is needed.

Remove one of two identical switches

Not supported double switch

—————————————————————————————————————-

B151031

Flexible switch responce to flexible switch panel invalid: not possible to idenfity ID (switch ID0 reported by FSP).

No Signal

Corresponding FS ignored.

Flexible switch failure

Diagnostic Service 14. No additional action is needed.

Replace faulty Flexible Switch

Flexible Switch

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

—————————————————————————————————————-

B151095

Flexible switch requested to be present in configuration is missing.

Incorrect Assembly

Corresponding FS ignored.

1.  Configuration failure;

2. Flexible switch removed/disconnected;

3. Flexible switch panel failure.

4. Flexible switch failure.

Diagnostic Service 14. No additional action is needed.

– Inspect flexible switch panel

– Inspect the harness

– Inspect flexible switches connection

Flexible Switch

—————————————————————————————————————-

B100411

Output short-circuit to GND.

Circuit Short To Ground

ECU behaviour: Current operation aborted until new

request.

1. Harness issue.

Diagnostic Service 14. No additional action is needed.

– Inspect the Front Lid Lock Relay 1 Control Circuit

– Inspect the harness

Front Lid Lock Relay 1 Control Circuit

—————————————————————————————————————-

B100412

Output short-circuit to BAT+.

Circuit Short To Battery

System effect: Latch is not possible to lock or/and to

unlock.

1. Harness issue.

Diagnostic Service 14. No additional action is needed.

– Inspect the Front Lid Lock Relay 1 Control Circuit

– Inspect the harness

Front Lid Lock Relay 1 Control Circuit

—————————————————————————————————————-

B100413

Open circuit conditions detected on output pin.

Threshold for open circuit detection:

<100uA @ 0,8V.

Circuit Open

System effect: Latch is not possible to lock or/and to unlock.

1. Harness issue;

2. Control relay issue (FRC).

3. CIOM internal HW failure;

Diagnostic Service 14. No additional action is needed.

– Inspect the Front Lid Lock Relay 1 Control Circuit

– Inspect the harness

Front Lid Lock Relay 1 Control Circuit

—————————————————————————————————————-

B100416

Feedback voltage measured on the output is lower defined threshold (configurable).

Threshold:

<(0.1*VBAT)-0.2.

Circuit Voltage Below Threshold

System effect: Latch is not possible to lock or/and to unlock. Operation is not completed.

1. Harness issue;

2. CIOM internal HW failure;

Diagnostic Service 14. No additional action is needed.

– Inspect the Front Lid Lock Relay 1 Control Circuit

– Inspect the harness

Front Lid Lock Relay 1 Control Circuit

—————————————————————————————————————-

B100417

Feedback voltage measured on the output is higher defined threshold (configurable).

Threshold:

<0.05*VBAT.

Circuit Voltage Above Threshold

System effect: Latch is not possible to lock or/and to unlock. Operation is not completed.

1. Harness issue;

2. CIOM internal HW failure;

Diagnostic Service 14. No additional action is needed.

– Inspect the Front Lid Lock Relay 1 Control Circuit

– Inspect the harness

Front Lid Lock Relay 1 Control Circuit

—————————————————————————————————————-

B100511

Output short-circuit to GND.

Circuit Short To Ground

ECU behaviour: Current operation aborted until new request.

1. Harness issue.

Diagnostic Service 14. No additional action is needed.

– Inspect the Front Lid Lock Relay 2 Control Circuit

– Inspect the harness

Front Lid Lock Relay 2 Control Circuit

—————————————————————————————————————-

B100512

Output short-circuit to BAT+.

Circuit Short To Battery

System effect: Latch is not possible to lock or/and to unlock.

1. Harness issue.

Diagnostic Service 14. No additional action is needed.

– Inspect the Front Lid Lock Relay 2 Control Circuit

– Inspect the harness

Front Lid Lock Relay 2 Control Circuit

—————————————————————————————————————-

B100513

Open circuit conditions detected on output pin.

Threshold for open circuit detection:

<100uA @ 0,8V.

Circuit Open

System effect: Latch is not possible to lock or/and to unlock.

1. Harness issue;

2. Control relay issue (FRC).

3. CIOM internal HW failure;

Diagnostic Service 14. No additional action is needed.

– Inspect the Front Lid Lock Relay 2 Control Circuit

– Inspect the harness

Front Lid Lock Relay 2 Control Circuit

—————————————————————————————————————-

B100516

Feedback voltage measured on the output is lower defined threshold (configurable).

Threshold:

<(0.1*VBAT)-0.2.

Circuit Voltage Below Threshold

System effect: Latch is not possible to lock or/and to unlock. Operation is not complited.

1. Harness issue;

2. CIOM internal HW failure;

Diagnostic Service 14. No additional action is needed.

– Inspect the Front Lid Lock Relay 2 Control Circuit

– Inspect the harness

Front Lid Lock Relay 2 Control Circuit

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

—————————————————————————————————————-

B100517

Feedback voltage measured on the output is higher defined threshold (configurable).

Threshold:

<0.05*VBAT.

Circuit Voltage Above Threshold

System effect: Latch is not possible to lock or/and to unlock. Operation is not completed.

1. Harness issue;

2. CIOM internal HW failure;

Diagnostic Service 14. No additional action is needed.

– Inspect the Front Lid Lock Relay 2 Control Circuit

– Inspect the harness

Front Lid Lock Relay 2 Control Circuit

—————————————————————————————————————-

B151312

Resident voltage level in circuit when not expected by function.

Circuit Short To Battery

– if direct 24V short circuit with fuse, fuse or button itself will blow when button is pressed;

– if short circuit with protected output, this output will be affected when button is pressed (short to ground from

output perspective);

1. Harness issue.

Diagnostic Service 14. No additional action is needed.

– Inspect the Front Lid Latch Sensor

– Inspect the harness

Front Lid Latch Sensor

—————————————————————————————————————-

B150E16

Keyfob battery voltage below threshold.

Circuit Voltage Below Threshold

Keyfob button requests will be executed intermittently or not executed.

Keyfob battery voltage too low

Diagnostic Service 14. No additional action is needed.

Replace Keyfob battery

Key Fob

—————————————————————————————————————-

B150E63

One of the keyfob buttons stay too long time in press position, more than

10s.

Circuit / Component Protection Time-Out

Keyfob goes to local save power mode.

1. Button failure.

2. Driver press the button too long time.

Diagnostic Service 14. No additional action is needed.

– Inspect Keyfob

Note:

– DID P1DJ8 can be used to get additional information.

Key Fob

—————————————————————————————————————-

B151463

Switch stay in push state more than allowed time: depends of P1CUF.

Circuit / Component Protection Time-Out

Accordingly to functional requirements.

1. Button failure.

2. Driver press the button too long time.

Diagnostic Service 14. No additional action is needed.

Inspect Loading Level Flexible Switch

Loading Level Flexible Switch

—————————————————————————————————————-

B151763

Switch stay in push state more than allowed time: depends of P 1EXK.

Circuit / Component Protection Time-Out

Accordingly to functional requirements.

1. Button failure.

2. Driver press the button too long time.

Diagnostic Service 14. No additional action is needed.

Inspect Ferry Flexible Switch

Ferry Flexible Switch

—————————————————————————————————————-

B151863

Switch stay in push state more than allowed time: depends of           P 1DWD.

Circuit / Component Protection Time-Out

Accordingly to functional requirements.

1. Button failure.

2. Driver press the button too long time.

Diagnostic Service 14. No additional action is needed.

Inspect Kneeling Flexible Switch

Kneeling Flexible Switch

—————————————————————————————————————-

B151963

Switch stay in push state more than allowed time: depends of P1IZ2.

Circuit / Component Protection Time-Out

Accordingly to functional requirements.

1. Button failure.

2. Driver press the button too long time.

Diagnostic Service 14. No additional action is needed.

Inspect Loading Level Adjustment Flexible Switch

Loading Level Adjustment Flexible Switch

—————————————————————————————————————-

B151A63

Switch stay in push state more than allowed time: depends of P1LXQ.

Circuit / Component Protection Time-Out

Accordingly to functional requirements.

1. Button failure.

2. Driver press the button too long time.

Diagnostic Service 14. No additional action is needed.

Inspect Front Park Brake Release Flexible Switch

Front Park Brake Release Switch

—————————————————————————————————————-

B151512

Resident voltage level when not expected by function.

Circuit Short To Battery

– if direct 24V short circuit with fuse, fuse or button itself will blow when button is pressed;

– if short circuit with protected output, this output will be affected when button is pressed (short to ground from

output perspective);

1. Harness issue.

Diagnostic Service 14. No additional action is needed.

– Inspect Luggage Compartment Switch

– Inspect the harness

Luggage Compartment Switch

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

—————————————————————————————————————-

B100011

Output short-circuit

to GND

Circuit Short To Ground

Output activation

forbidden.

1. Harness issue.

2. ESCL internal failure.

Diagnostic Service 14. No additional

action is needed.

– Inspect the ESCL Logic Activation Power Supply Circuit

– Inspect the harness

ESCL Logic Activation

Power Supply Circuit

—————————————————————————————————————-

B100012

Output short-circuit to BAT+.

Circuit Short To Battery

Output activation forbidden.

1. Harness issue.

2. CIOM internal failure (very low probability).

Diagnostic Service 14. No additional action is needed.

– Inspect the ESCL Logic Activation Power Supply Circuit

– Inspect the harness

ESCL Logic Activation Power Supply Circuit

—————————————————————————————————————-

B100013

Open circuit conditions detected on output pin

Circuit Open

ATTENTION: this diagnostic is disabled.

DTC, output activation

forbidden.

“1. Harness issue;

2. CIOM internal HW failure;”

Diagnostic Service 14. No additional action is needed.

– Inspect the ESCL Logic Activation Power Supply Circuit

– Inspect the harness

ESCL Logic Activation Power Supply Circuit

—————————————————————————————————————-

B100016

Feedback voltage measured on the output is lower defined threshold. Threshold:  < Vbat – 2V.

Circuit Voltage Below Threshold

Output activation forbidden.

1. Harness issue;

2. CIOM internal HW failure;

Diagnostic Service 14. No additional action is needed.

– Inspect the ESCL Logic Activation Power Supply Circuit

– Inspect the harness

ESCL Logic Activation Power Supply Circuit

—————————————————————————————————————-

B100017

Feedback voltage measured on the output is higher defined threshold. Threshold: 5V.

Circuit Voltage Above Threshold

Output activation forbidden

1. Harness issue;

2. CIOM internal HW failure;

Diagnostic Service 14. No additional action is needed.

– Inspect the ESCL Logic Activation Power Supply Circuit

– Inspect the harness

ESCL Logic Activation Power Supply Circuit

—————————————————————————————————————-

B151212

Resident voltage level when not expected by function.

Circuit Short To Battery

– if direct 24V short circuit with fuse, fuse or button itself will blow when button is pressed;

– if short circuit with protected output, this output will be affected when button is pressed (short to ground from

output perspective);

1. Harness issue.

Diagnostic Service 14. No additional action is needed.

– Inspect the Swivel Seat Switch

– Inspect the harness

Swivel Seat Switch

—————————————————————————————————————-

B150F63

Switch stay in push state more than allowed time: > 90s.

Circuit / Component Protection Time-Out

Accordingly to functional requirements.

“1. Button failure.

2. Driver press the button too long time.”

Diagnostic Service 14. No additional action is needed.

Inspect Traction switch

Traction switch

—————————————————————————————————————-

U115054

No at least one Immobilizer Transponder Matching procedure performed.

Missing Calibration

Immobilizer function always active

Not possible to crank

1. Invalid ECU installation procedure: Immobilizer Transponder Matching procedure not performed;

2. ECU internal failure, to be rised to back-office.

Diagnostic Service 14. No additional action is needed.

Perform Immobilizer Transponder Matching procedure

Immobilizer Transponder Data Link

—————————————————————————————————————-

U115081

CIOM – Keyfob transponder communication

failure.

Invalid Serial Data Received

PIN code strategy activation.

1. Transponder NOK;

2. CIOM internal falure.

Diagnostic Service 14. No additional action is needed.

Inspect the Immobilizer Transponder

Immobilizer Transponder Data Link

—————————————————————————————————————-

U115088

CIOM – Immobilizer antenna link NOK.

Bus off

PIN code strategy activation.

1. Harness issue: antenna disconnected, SC to GND.

2. Antenna failure.

Diagnostic Service 14. No additional action is needed.

– Inspect the Immobilizer Transponder

– Inspect the harness

Immobilizer Transponder Data Link

Node

DTC ISO

FailureEvent

FTB_Name

FunctBehaviorDesc

PossibleRootCause

ProcedureEraseConfirmedDtc

ProposedWorkshopAction

ProprietaryName

—————————————————————————————————————-

B151363

Front Lid Lock Sensor has not changed the state to expected value (lock or unlock position accordingly to ongoing operation) in defined time (development configurable value).

Circuit / Component Protection Time-Out

Latch controlled maximum allowed time.

Continuous application of the maximum time operation can result in premature wear of the latch.

– harness issue on frond lid lock control system

– sensor failure (if latch state confirmed physically)

– front lid latch broken

Diagnostic Service 14. No additional action is needed.

– Inspect the Front Lid Latch Sensor

Front Lid Latch Sensor

—————————————————————————————————————-

B150463

Signal from LIN slave stay in active state too long time: depends of switch. See Proposed Workshop Action for more information.

Circuit / Component Protection Time-Out

Accordingly to functional requirements.

1. Button failure.

2. Driver press the button too long time.

Diagnostic Service 14. No additional action is needed.

Inspect Wired Control ECS Panel

Wired Control ECS Panel

Skype
Telegram
WhatsApp
Email

Политика    Контакты

© Copyright 2024 DTCON.EU Powered by VHF84
© Copyright 2024 DTCON.EU Powered by VHF84
© Copyright 2024 DTCON.EU Powered by VHF84
error: Внимание: Контент защищён!