U005588
CAN Security Subnet is off.
Bus off
Lack of CAN communication causes:
– Alarm can not be armed or disarmed
– sensors which are delivered via CAN can not trigger
an alarm
– no feedback to CIOM about current Alarm ECU
state
– no feedback to CIOM about last alarm reason
– no feedback to CIOM about active DTCs in Alarm
ECU (fault event gateway)
– alarm is not triggered due to lack of CAN
communication
CAN_H is shorted to GND CAN_L is shorted to UBATT
Diagnostic Service 14. No additional action is needed.
Inspect the harness or connectors.
CAN Communication Security Net
————————————————————————————————————————————————————————————–
U300041
Parameters checksum not valid.
General Checksum Failure
Boodloader is informed about this fault and then
application will be never
started after reset.
AECU configuration parameters corrupted.
Diagnostic Service 14. No additional action is needed.
Replace the component and send it to backoffice
Electronic control unit
————————————————————————————————————————————————————————————–
U300044
AECU volatile memory error
Data Memory Failure
SW does not specify any
functional behavior when this DTC is set.
AECU corrupted.
Diagnostic Service 14. No additional action is needed.
Replace the component and send it to backoffice.
Electronic control unit
————————————————————————————————————————————————————————————–
U300045
AECU non-volatile memory error
Program Memory Failure
Boodloader is informed about this fault and then
application will be never
started after reset.
AECU corrupted.
Diagnostic Service 14. No additional action is needed.
Replace the component and send it to backoffice.
Electronic control unit
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
————————————————————————————————————————————————————————————–
U300046
AECU EEPROM is
corrupted.
Calibration / Parameter Memory Failure
SW does not specify any functional behavior when
this DTC is set.
AECU corrupted.
Diagnostic Service 14. No additional action is needed.
Replace the component and send it to backoffice.
Electronic control unit
————————————————————————————————————————————————————————————–
U300049
AECU internal
hardware fault – CPU clock failure
Internal Electronic Failure
SW does not specify any functional behavior when
this DTC is set.
AECU corrupted.
Diagnostic Service 14. No additional action is needed.
Replace the component and send it to backoffice.
Electronic control unit
————————————————————————————————————————————————————————————–
U300054
Routine for Ultrasonic/Inclinatio n Sensors calibration
has to be started. If routine ended successful then DTC will be PASSED, when
routine failed then DTC will be FAILED. Until routine starts the DTC will be
NOT TESTED.
Missing Calibration
Any defects regarding Calibration for
Ultrasonic/Inclination sensors can cause invalid work of
Ultrasonic/Inclination sensors:
– Ultrasonic/Inclination sensors can be more or less
sensitive and alarm can be false generated or at all
– Ultrasonic/Inclination sensors can not be activated.
So no alarm due to: movement detection or inclination
Ultrasonic/Inclination Sensors Calibration Routine not
completed
– or wrong calibration data
– or lost communication with sensor
– or calibration verification not passed.
Diagnostic Service 14. No additional action is needed.
Perform the calibration of MDD sensors (launch the
routines R1AIA & R1AIB).
Electronic control unit
————————————————————————————————————————————————————————————–
U300094
AECU will be reset
due to watchdog timer expiration
Unexpected Operation
SW does not specify any
functional behavior when this DTC is set.
SW Failure.
Diagnostic Service 14. No additional action is needed.
Replace the component and send it to backoffice.
Electronic control unit
————————————————————————————————————————————————————————————–
U300316
AECU power supply
<17V
Circuit Voltage Below Threshold
It can cause:
– power supply for MDD and siren can not be
maintained. It can cause that alarm is triggered or MDD and siren can not be
armed
– power supply for uController is too low and Alarm ECU
works unstable. False alarm possible.
Battery level is below 17V.
Diagnostic Service 14. No additional action is needed.
Inspect the battery Inspect the harness
Battery Power
————————————————————————————————————————————————————————————–
U300317
AECU power supply
> 31V
Circuit Voltage Above Threshold
It can cause:
– alarm ECU hardware can be damged
Alternator/external charger voltage above 31V
Diagnostic Service 14. No additional action is needed.
Inspect the battery Inspect the harness
Battery Power
————————————————————————————————————————————————————————————–
B150697
Panic button stays in pushed state longer as defined in
PanicCabButtonPuls eTimeout parameter.
Component or System Operation Obstructed or Blocked
Presence of defect inhibits the Panic Alarm button.
Panic button hardware failure.
Diagnostic Service 14. No additional action is needed.
Inspect the battery Inspect the harness
Panic button
————————————————————————————————————————————————————————————–
B150249
Siren internal fault
Internal Electronic Failure
Siren won’t ring.
Siren corrupted.
Diagnostic Service 14. No additional action is needed.
Replace the siren and send it to backoffice.
Siren Module
————————————————————————————————————————————————————————————–
B150268
Siren and AECU not correctly paired.
Event Information
Not possible to leave service mode.
Interruption of the procedure
or
Siren corrupted. Or Siren missing.
Diagnostic Service 14. No additional action is needed.
Check siren connection else
Replace the siren and send it to backoffice.
Siren Module
————————————————————————————————————————————————————————————–
B150287
Siren doesn’t communicate with
Alarm ECU.
Missing Message
Siren won’t ring.
Connector between the truck wiring harness and the
Siren detached.
Diagnostic Service 14. No additional action is needed.
Inspect the siren, the connector and the harness.
Siren Module
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
————————————————————————————————————————————————————————————–
B150349
Ultrasonic/Inclinatio n Sensors internal fault
Internal Electronic Failure
Data from Ultrasonic/Inclination Sensors are invalid
and might not detect movement in cab, or generate false alarm.
1. internal eeprom in ultrasonic or inclination
sensor
2. bad result of ultrasonic
selftest (selftest is run just before ultrasonic is being armed)
3. bad result of inclination sensor
(selftest is run just before inclination is being armed)
Two possible causes for defect 2 & 3:
– missing microphone or
sounder connected to ultrasonic
– bad position of
inclination sensor. Sensor shall lie horizontally, not tilted, not aside
Diagnostic Service 14. No additional action is needed.
First check MDD position
Then check microphone & sounder
If no issue found, replace the MDD and send it to
backoffice.
Motion Detection Module
————————————————————————————————————————————————————————————–
B150387
Ultrasonic/Inclinatio n Sensors don’t communicated with
Alarm ECU.
Missing Message
Ultrasonic/Inclination Sensors can’t trigger alarm:
movement detection or inclination detection won’t
work.
Connector between wiring harness of the truck and the
Ultrasonic/Inclination Sensors detached.
Diagnostic Service 14. No additional action is needed.
Inspect the MDD, the connector and the harness.
Motion Detection Module
————————————————————————————————————————————————————————————–
U114111
Communication network between AECU,
Ultrasonic/Inclinatio n Sensors, Siren have been
shorted to ground.
Circuit Short To Ground
If the Alarm System is in Service Mode, the Siren
doesn’t ring.
Else, the siren is triggered and rings as if the system
was hacked
Ultrasonic/Inclination Sensors don’t trigger the Alarm
system.
Wiring harness faulty
Diagnostic Service 14. No additional action is needed.
– Inspect the Siren, the MDD
– Inspect the harness and connectors.
Alarm Private Net
————————————————————————————————————————————————————————————–
U114112
Communication network between AECU,
Ultrasonic/Inclinatio n Sensors, Siren have been
shorted to Ubatt.
Circuit Short To Battery
If the Alarm System is in Service Mode, the Siren
doesn’t ring.
Else, the siren is triggered and rings as if the system
was hacked
Ultrasonic/Inclination Sensors don’t trigger the Alarm
system.
Wiring harness faulty
Diagnostic Service 14. No additional action is needed.
– Inspect the Siren, the MDD
– Inspect the harness and connectors.
Alarm Private Net
————————————————————————————————————————————————————————————–
U114186
Communication network between AECU,
Ultrasonic/Inclinatio n Sensors, Siren not
valid.
Signal Invalid
Data from Ultrasonic/Inclination Sensors, or siren are
invalid and it might cause:
– generate false alarm
1. Wiring harness faulty
2. EMC problem
Diagnostic Service 14. No additional action is needed.
– inspect the MDD and the siren
– replace the component and send it to backoffice
Alarm Private Net
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
————————————————————————————————————————————————————————————–
B150411
AECU 12V Power supply output to Ultrasonic/Inclinatio n
Sensors and Siren has been shorted to ground.
Circuit Short To Ground
When defect is present then 12V (Power supply for Siren
and Ultrasonic/Inclination Sensors) is switched off.
After that, every 1sec there is an attempt to switch on
12V. Those attempts are performed as long as short is present.
Presence of short 12V at arming siren or
Ultrasonic/Inclination Sensors causes that siren and Ultrasonic/Inclination
can not be armed.
When presence of short 12V takes place when siren is
already armed than alarm is triggered. Siren starts sounding using backup
battery. In that case siren backup battery must be already charged.
Wiring harness faulty
Diagnostic Service 14. No additional action is needed.
– inspect the MDD and the siren
– inspect the harness
Alarm Private Net Modules Supply Circuit
————————————————————————————————————————————————————————————–
B150417
AECU 12V Power supply output to Ultrasonic/Inclinatio n
Sensors and Siren
>12V
Circuit Voltage Above Threshold
When defect is present then 12V (Power supply for Siren
and Ultrasonic/Inclination Sensors) is switched off.
After that, every 1sec there is an attempt to switch on
12V. Those attempts are performed as long as short is present.
Presence of short 12V at arming siren or
Ultrasonic/Inclination Sensors causes that siren and Ultrasonic/Inclination
Sensors can not be armed.
When presence of short 12V takes place when siren is
already armed than alarm is triggered. Siren starts sounding using backup
battery. In that case siren backup battery must be already charged.
Wiring harness faulty
Diagnostic Service 14. No additional action is needed.
– inspect the MDD and the siren
– inspect the harness
Alarm Private Net Modules Supply Circuit
————————————————————————————————————————————————————————————–
B150511
AECU output to LED has been shorted to ground.
Circuit Short To Ground
LED is permanently OFF and it doesn’t reflect current
Alarm ECU state (e.g. UNSET- no blink LED, SET- blink LED 1Hz etc).
Wiring harness faulty
Diagnostic Service 14. No additional action is needed.
– inspect the LED
– inspect the harness
LED Power Supply Circuit
Node
DTC ISO
FailureEvent
FTB_Name
FunctBehaviorDesc
PossibleRootCause
ProcedureEraseConfirmedDtc
ProposedWorkshopAction
ProprietaryName
————————————————————————————————————————————————————————————–
U1FFF68
Factory mode active.
Event Information
Not possible to leave service mode. Alarm is not armed.
P1C54 set to true.
Diagnostic Service 14. No additional action is needed.
Exit Factory Mode
Factory Mode Active